3D Computer graphical anatomy study of the femur: a basis for a new nail design

BackgroundCurrent intramedullary nails with a radius of curvature (ROC) of 1500–2000 mm sometimes cause distal anterior cortical encroachment. Furthermore, clinical data indicate that the proximal nail end is too long for some Asian patients. The objective of our study was to develop a comprehensive 3D measurement protocol that measures both the anatomy of the canal and the proximal region. The protocol was used to obtain measurements from Caucasian and Asian (Japanese and Thai) specimens.Materials and methodsA total of 90 3D bone models representative of hip fracture patients were reconstructed from CT data. RapidForm 2006 was used to generate the reference geometries required for determining radius and angulation of shaft antecurvature as well as measurements of the proximal anatomy. Multiple linear regression analyses were used to determine the relative contribution of height, age, ethnicity, gender, and body side on the total variance.ResultsThe mean ROC in the natural 3D antecurvature plane was 885 mm overall, 974 mm in Caucasians and 787 mm in Asians. Height, age, ethnicity, gender, and body side significantly predicted ROC (R = 0.53, p = 0.000). The mean values of anteversion measurements for Asians (Japanese: 22.1°; Thai: 22.7°) were significantly larger than those of the Caucasians (14.5°; p = 0.001). There was virtually no difference (p = 0.186) between the measurements pertaining to the length of the proximal nail end between Caucasian and Asian samples. There was no significant difference between the mean neck-to-shaft angles (Caucasian: 126°; Japanese: 128.2°; Thai: 125.7°; p = 0.198 for Asians vs Caucasians).ConclusionsThe developed comprehensive anatomical 3D measurement protocol could serve as standardised approach for anthropometric studies in the future. Our data suggest that the ROC of current nail designs should be reduced from between 1500 and 2000 to 1000 mm to achieve an improved fit for the investigated population.

[1]  Gerhard Küntscher,et al.  Die Marknagelung von Knochenbrüchen , 1940, Klinische Wochenschrift.

[2]  R. Zickel A new fixation device for subtrochanteric fractures of the femur: a preliminary report. , 1967, Clinical orthopaedics and related research.

[3]  E. Schneider,et al.  [Form and dimension of the bone marrow cavity of the human femur with reference to the fit of intramedullary implants]. , 1988, Der Unfallchirurg.

[4]  Lei Liu,et al.  Results of the proximal femoral nail anti-rotation (PFNA) in elderly Chinese patients , 2009, International Orthopaedics.

[5]  M. Hartel,et al.  Femoral antecurvation—A 3D CT Analysis of 1232 adult femurs , 2018, PloS one.

[6]  H. Tullos,et al.  The effect of aging on the shape of the proximal femur. , 1995, Clinical orthopaedics and related research.

[7]  Eric Y Chang,et al.  Mismatch of Current Intramedullary Nails With the Anterior Bow of the Femur , 2004, Journal of orthopaedic trauma.

[8]  T. Terjesen,et al.  Femoral anteversion in normal adults. Ultrasound measurements in 50 men and 50 women. , 1992, Acta orthopaedica Scandinavica.

[9]  John D. Koerner,et al.  Femoral Version of the General Population: Does “Normal” Vary by Gender or Ethnicity? , 2013, Journal of orthopaedic trauma.

[10]  W. Buford,et al.  Three-Dimensional Computed Tomography–Based Modeling of Sagittal Cadaveric Femoral Bowing and Implications for Intramedullary Nailing , 2014, Journal of orthopaedic trauma.

[11]  P. Procter,et al.  Geometric Mismatch of the Gamma Nail to the Chinese Femur , 1996, Clinical orthopaedics and related research.

[12]  Banchong Mahaisavariya,et al.  Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering. , 2002, Medical engineering & physics.

[13]  C. Collinge,et al.  Does Modern Nail Geometry Affect Positioning in the Distal Femur of Elderly Patients With Hip Fractures? A Comparison of Otherwise Identical Intramedullary Nails With a 200 Versus 150 cm Radius of Curvature , 2013, Journal of orthopaedic trauma.

[14]  W. Carson,et al.  Curvature of the Femur and the Proximal Entry Point for an Intramedullary Rod , 1987, Clinical orthopaedics and related research.

[15]  K. Koval,et al.  Cortical Encroachment After Cephalomedullary Nailing of the Proximal Femur: Evaluation of a More Anatomic Radius of Curvature , 2013, Journal of orthopaedic trauma.

[16]  F. Kummer,et al.  Intramedullary Nailing of the Lower Extremity: Biomechanics and Biology , 2007, The Journal of the American Academy of Orthopaedic Surgeons.

[17]  Michael J Gardner,et al.  Is There a Standard Trochanteric Entry Site for Nailing of Subtrochanteric Femur Fractures? , 2011, Journal of orthopaedic trauma.

[18]  Anthony Skalak,et al.  Proximal Femoral Anatomy in the Normal Human Population , 2009, Clinical orthopaedics and related research.

[19]  Ahmet Harma,et al.  Femoral shaft bowing with age: a digital radiological study of Anatolian Caucasian adults. , 2008, Diagnostic and interventional radiology.

[20]  M. Bottlang,et al.  Femoral Nailing Through the Trochanter: The Reamer Pathway Indicates a Helical Nail Shape , 2006, Journal of orthopaedic trauma.

[21]  R. Jantz,et al.  Secular change in long bone length and proportion in the United States, 1800-1970. , 1999, American journal of physical anthropology.

[22]  Yasuhiko Saito,et al.  How accurate are self‐reported height, weight, and BMI among community‐dwelling elderly Japanese?: Evidence from a national population‐based study , 2012, Geriatrics & gerontology international.

[23]  R. Ostrum,et al.  Penetration of the Distal Femoral Anterior Cortex During Intramedullary Nailing for Subtrochanteric Fractures: A Report of Three Cases , 2005 .

[24]  R. D. de Wit,et al.  First experience and complications with the long Gamma nail. , 1993, The Journal of trauma.

[25]  O. Reikerås,et al.  Femoral neck angles: a specimen study with special regard to bilateral differences. , 1982, Acta orthopaedica Scandinavica.

[26]  F. Hoaglund,et al.  Anatomy of the femoral neck and head, with comparative data from Caucasians and Hong Kong Chinese. , 1980, Clinical orthopaedics and related research.

[27]  Beat Schmutz,et al.  Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructions. , 2011, Medical engineering & physics.

[28]  Low Wd,et al.  Anatomy of the femoral neck and head, with comparative data from Caucasians and Hong Kong Chinese. , 1980 .

[29]  Sven Holcombe,et al.  Variation in the Femoral Bow: A Novel High-Throughput Analysis of 3922 Femurs on Cross-Sectional Imaging , 2014, Journal of orthopaedic trauma.