Treadmill training of paraplegic patients using a robotic orthosis.

Recent studies have confirmed that regular treadmill training can improve walking capabilities in incomplete spinal cord-injured subjects. At the beginning of this training the leg movements of the patients have to be assisted by physiotherapists during gait on the moving treadmill. The physical capabilities and the individual experience of the therapists usually limit this training. A driven gait orthosis (DGO) has been developed that can move the legs of a patient in a physiological way on the moving treadmill. The orthosis is adjustable in size so different patients can use it. Actuators at the knee and hip joints are controlled by a position controller. With the DGO the legs of patients with different degrees of paresis and spasticity could be trained for more than half an hour, and physiological gait patterns were obtained.

[1]  J Hughes Powered lower limb orthotics in paraplegia , 1972, Paraplegia.

[2]  S. Grillner Control of Locomotion in Bipeds, Tetrapods, and Fish , 1981 .

[3]  S. Rossignol,et al.  Recovery of locomotion after chronic spinalization in the adult cat , 1987, Brain Research.

[4]  E. Rabischong,et al.  Control and command of a six degrees of freedom active electrical orthosis for paraplegic patient , 1990, EEE International Workshop on Intelligent Robots and Systems, Towards a New Frontier of Applications.

[5]  A. Wernig,et al.  Laufband locomotion with body weight support improved walking in persons with severe spinal cord injuries , 1992, Paraplegia.

[6]  Richard A. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[7]  V. Dietz,et al.  Locomotor activity in spinal man , 1994, The Lancet.

[8]  A. Wernig,et al.  Laufband Therapy Based on‘Rules of Spinal Locomotion’is Effective in Spinal Cord Injured Persons , 1995, The European journal of neuroscience.

[9]  V. Dietz,et al.  Locomotor capacity of spinal cord in paraplegic patients , 1995, Annals of neurology.

[10]  Ruthenberg Bj,et al.  An experimental device for investigating the force and power requirements of a powered gait orthosis. , 1997 .

[11]  B. Ruthenberg,et al.  An experimental device for investigating the force and power requirements of a powered gait orthosis. , 1997, Journal of rehabilitation research and development.

[12]  H Barbeau,et al.  Walking after spinal cord injury: evaluation, treatment, and functional recovery. , 1999, Archives of physical medicine and rehabilitation.

[13]  S Hesse,et al.  Treadmill walking with partial body weight support versus floor walking in hemiparetic subjects. , 1999, Archives of physical medicine and rehabilitation.