New aspects of UHF PD diagnostics on gas-insulated systems

Gas insulated switchgears (GIS) have been increasingly introduced as main substation equipment since the late 1960s thanks to their high reliability, safety, and compactness. The UHF method to diagnose partial discharge (PD) is broadly employed in the field as an advanced insulation diagnostic technology. There are three primary factors related to the PD signal detection characteristics using this UHF method; namely the frequency spectrum of the PD signal itself inside GIS, the propagation characteristics of the PD signal inside the GIS tank, and the detection characteristics of the sensor measuring the PD signal. Accordingly, to further improvement of the diagnostic technique based on the UHF method, the PD phenomenon itself and its propagation characteristics should be clarified and the measurement system refined. From these perspectives, the present study reviewed the recent and latest findings concerning the PD phenomenon and its propagation characteristics inside GIS as well as the PD measurement system verification methods and diagnostic technologies, and summarized typical examples. Firstly, with regard to the PD phenomenon, measurement up to the high frequency band exceeding 10 GHz (even 30 GHz) clarified that the rise time of the PD current waveform is several tens of picoseconds, shorter than previously known. In the case of PD in micro-defects inside the epoxy insulator, however, the rise time is relatively long, in the order of nanoseconds, and a crack is the most critical defect. Subsequently, with regard to UHF PD diagnostics/monitoring technology, a novel technique using PD current waveform characteristics has been developed, and a more advanced PD diagnostic algorithm has been established by clarifying the influence of the shape and GIS internal structures on the electromagnetic wave propagation characteristics. Less uncertain and simplified calibration and verification technologies are also proposed both for a single UHF sensor and the entire UHF measurement system. These new technologies and further advanced studies in future are expected to make the UHF method more convenient and sophisticated.

[1]  D CigreWg,et al.  High-Voltage On-Site Testing with Partial Discharge Measurement , 2012 .

[2]  U. Schichler,et al.  UHF PD detection in GIS substations during on-site testing , 2000 .

[3]  H. Okubo,et al.  Detection of harmful metallic particles inside gas insulated switchgear using UHF sensor , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Martin D. Judd,et al.  Partial discharge diagnostics for gas insulated substations , 1995 .

[5]  Shigemitsu Okabe,et al.  Improving the sensitivity verification method of the UHF PD detection technique for GIS , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  S. Okabe,et al.  Insulation performance of three types of micro-defects in inner epoxy insulators , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  H. Muto,et al.  Partial discharge diagnosis method using electromagnetic wave mode transformation in actual GIS structure , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[8]  H. Muto,et al.  Propagation properties of electromagnetic wave through T-branch in GIS , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[9]  H. Okubo,et al.  A novel technique for partial discharge and breakdown investigation based on current pulse waveform analysis , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Alstom Grid Calibration of UHF Sensors for GIS:Comparison of Different Methods and Testing of a Calibration System Based on a Conical Antenna , 2011 .

[11]  S. Okabe,et al.  Propagation properties of PD-induced electromagnetic wave in 66 kV GIS model tank with L branch structure , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  M. Judd,et al.  Ultra-wide bandwidth measurement of partial discharge current pulses in SF6 , 2012 .