The cost of parallel imaging in functional MRI of the human brain.

While the advantages of parallel acquisition techniques for echo-planar imaging (EPI) are well documented for studies affected by magnetic field inhomogeneities, this work focuses on the costs in functional MRI of brain regions without artifacts due to susceptibility effects. For a visual stimulation paradigm and relative to conventional EPI (2.9 T; TR/TE=2000/36 ms), the use of parallel acquisition at a reduction factor of 2 decreased the mean number of activated voxels by 21% at 2 x 2 x 2-mm(3) resolution (n=6) and by 15% at 3 x 3 x 3-mm(3) resolution (n=6). The loss of sensitivity reflects both a decreased signal-to-noise ratio of the native images due to a lower number of contributing gradient echoes and a decreased BOLD MRI sensitivity due to the coverage of a smaller range of TEs.

[1]  P. Boesiger,et al.  SENSE‐DTI at 3 T , 2004, Magnetic resonance in medicine.

[2]  J Baudewig,et al.  Thresholding in correlation analyses of magnetic resonance functional neuroimaging. , 2003, Magnetic resonance imaging.

[3]  Christine Preibisch,et al.  Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI) , 2003, NeuroImage.

[4]  R. Stollberger,et al.  Improved diffusion‐weighted single‐shot echo‐planar imaging (EPI) in stroke using sensitivity encoding (SENSE) , 2001, Magnetic resonance in medicine.

[5]  Robert A. Österbauer,et al.  Sensitivity‐encoded single‐shot spiral imaging for reduced susceptibility artifacts in BOLD fMRI , 2002, Magnetic resonance in medicine.

[6]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[7]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[8]  Peter Boesiger,et al.  Sensitivity-encoded (SENSE) echo planar fMRI at 3T in the medial temporal lobe , 2005, NeuroImage.

[9]  Peter Kellman,et al.  Application of sensitivity‐encoded echo‐planar imaging for blood oxygen level‐dependent functional brain imaging † , 2002, Magnetic resonance in medicine.

[10]  C. Stark,et al.  Neural activity during encoding predicts false memories created by misinformation. , 2005, Learning & memory.

[11]  J. Hogg Magnetic resonance imaging. , 1994, Journal of the Royal Naval Medical Service.

[12]  E. Williams Experimental Designs Balanced for the Estimation of Residual Effects of Treatments , 1949 .

[13]  S. Holm A Simple Sequentially Rejective Multiple Test Procedure , 1979 .

[14]  C. Stark,et al.  Medial temporal lobe activation during encoding and retrieval of novel face-name pairs , 2004, Hippocampus.