Geometric Performance and Efficiency of an Optical Tracking System for Daily Pre-treatment Positioning in Pelvic Radiotherapy Patients

The purpose of this study was to characterize the accuracy of a novel in-house optical tracking system (OTS), and to determine its efficiency for daily pre-treatment positioning of pelvic radiotherapy patients compared to conventional optical distance indicator (ODI) methodology. The OTS is comprised of a passive infrared stereoscopic camera, and custom control software for use in assisting radiotherapy patient setup. Initially, the system was calibrated and tested for stability inside a radiation therapy treatment room. Subsequently, under an ethics approved protocol, the clinical efficiency of the OTS was compared to conventional ODI setup methodology through 17 pelvic radiotherapy patients. Differences between orthogonal source-to-skin distance (SSD) readings and overall set-up time resultant from both systems were compared. The precision of the OTS was 0.01 ± 0.01 mm, 0.02 ± 0.02 mm, and −0.01 ± 0.06 mm in the left/right (L/R), anterior/posterior (A/P), and cranial/caudal (C/C) directions, respectively. Discrepancies measured between the linac radiographic center in the treatment room and the calibrated origin of the camera (OTS) by two independent observers was submillimeter. Analysis of 146 fractions from 17 patients showed a high correlation between the SSD readings of the OTS and ODI setup methodologies (r = 0.99). The average time for pre-treatment positioning using the OTS couch shift calculation was 2.60 ± 0.69 minutes, and for conventional ODI setup, 3.62 ± 0.82 minutes; the difference of 1.02 minutes was statistically significant (p < 0.001). In conclusion, the OTS is a precise and robust tool for use as an independent check of treatment room patient positioning. The system is indicated as geometrically equivalent to current methods of daily pre-treatment patient positioning with potential for gains in efficiency by decreasing setup times in the treatment room.

[1]  Mark Oldham,et al.  Cone-beam-CT guided radiation therapy: A model for on-line application. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  Hilke Vorwerk,et al.  Interfractional and intrafractional accuracy during radiotherapy of gynecologic carcinomas: a comprehensive evaluation using the ExacTrac system. , 2003, International journal of radiation oncology, biology, physics.

[3]  Brian O'Sullivan,et al.  Measuring interfractional and intrafractional motion with cone beam computed tomography and an optical localization system for lower extremity soft tissue sarcoma patients treated with preoperative intensity-modulated radiation therapy. , 2008, International journal of radiation oncology, biology, physics.

[4]  D A Jaffray,et al.  A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. , 1999, International journal of radiation oncology, biology, physics.

[5]  Douglas R Wyman,et al.  Analysis of mechanical sources of patient alignment errors in radiation therapy. , 2002, Medical physics.

[6]  G Ferrigno,et al.  Real-time three-dimensional motion analysis for patient positioning verification. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  Cristina Garibaldi,et al.  3D optoelectronic analysis of interfractional patient setup variability in frameless extracranial stereotactic radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[8]  John M Buatti,et al.  Optically guided patient positioning techniques. , 2005, Seminars in radiation oncology.

[9]  J. Buatti,et al.  The University of Florida frameless high-precision stereotactic radiotherapy system. , 1997, International journal of radiation oncology, biology, physics.

[10]  Jeffrey H. Siewerdsen,et al.  Initial investigation of an automatic registration algorithm for surgical navigation , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  C. Mascott,et al.  Comparison of Magnetic Tracking and Optical Tracking by Simultaneous Use of Two Independent Frameless Stereotactic Systems , 2005, Neurosurgery.

[12]  T Liebler,et al.  An application framework for computer-aided patient positioning in radiation therapy , 2003, Medical informatics and the Internet in medicine.

[13]  Prakash Chinnaiyan,et al.  The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[14]  Timothy D. Solberg,et al.  Infrared patient positioning for stereotactic radiosurgery of extracranial tumors , 1999, Comput. Biol. Medicine.

[15]  Dirk Verellen,et al.  Clinical use of stereoscopic X-ray positioning of patients treated with conformal radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[16]  Markus Stock,et al.  Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking. , 2006, Medical physics.

[17]  Steve B. Jiang,et al.  Effects of motion on the total dose distribution. , 2004, Seminars in radiation oncology.

[18]  D. Jaffray,et al.  Review of image-guided radiation therapy , 2007, Expert review of anticancer therapy.

[19]  David A Jaffray,et al.  Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. , 2006, Medical physics.

[20]  Dirk Verellen,et al.  Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  Cristina Garibaldi,et al.  Robust frameless stereotactic localization in extra-cranial radiotherapy. , 2006, Medical physics.

[22]  D. Jaffray,et al.  Accuracy of automatic couch corrections with on‐line volumetric imaging * , 2009, Journal of applied clinical medical physics.

[23]  Jay B. West,et al.  Designing optically tracked instruments for image-guided surgery , 2004, IEEE Transactions on Medical Imaging.

[24]  S L Meeks,et al.  Optic-guided stereotactic radiotherapy. , 1998, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[25]  Andrew D. Wiles,et al.  Accuracy assessment and interpretation for optical tracking systems , 2004, Medical Imaging: Image-Guided Procedures.