Wind power plant enhancement with a fault current limiter

An important aspect of wind power plant (WPP) impact studies is to evaluate the short-circuit (SC) current contribution of the plant into the transmission network under different fault conditions. This task can be challenging to protection engineers due to the topology differences between different types of wind turbine generators (WTGs) and the conventional generating units. While it is important to size the circuit breaker to accommodate the available SC current, the available rating of a circuit breaker is limited. A fault current limiter (FCL) has the capability to limit the SC current, and in some cases, may be necessary to limit the SC current from a WPP to defer the replacement of a circuit breaker currently installed in the transmission line. This paper investigates the capability of a saturable core FCL to limit the SC current of different types of WTGs. Different faults are simulated to investigate the effectiveness of the FCL to limit the SC current and to reduce transient torque during faults. Several cases will be considered to demonstrate the benefits of using FCLs in unique situations.

[1]  Eduard Muljadi,et al.  Understanding the unbalanced-voltage problem in wind turbine generation , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[2]  F. Profumo,et al.  Design and performance of a digitally based voltage controller for correcting phase unbalance in induction machines , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[3]  Thomas A. Lipo,et al.  Induction Machine Phase Balancing by Unsymmetrical Thyristor Voltage Control , 1985, IEEE Transactions on Industry Applications.

[4]  N. Samaan,et al.  Power transformer application for wind plant substations , 2010, IEEE PES T&D 2010.

[5]  Eduard Muljadi,et al.  Wind Power Plant Short Circuit Current Contribution for Different Fault and Wind Turbine Topologies: Preprint , 2010 .

[6]  J. Morren,et al.  Short-Circuit Current of Wind Turbines With Doubly Fed Induction Generator , 2007, IEEE Transactions on Energy Conversion.

[7]  Franco Moriconi,et al.  Modeling and test validation of a 15kV 24MVA Superconducting Fault Current Limiter , 2010, IEEE PES T&D 2010.

[8]  E.A. DeMeo,et al.  Utility Wind Integration and Operating Impact State of the Art , 2007, IEEE Transactions on Power Systems.

[9]  Approved June,et al.  An American National Standard IEEE Application Guide for Capacitance Current Switching for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis , 1979 .