A mathematical model and inversion procedure for magneto-acousto-electric tomography

Magneto-acousto-electric tomography (MAET), also known as the Lorentz force or Hall effect tomography, is a novel hybrid modality designed to be a high-resolution alternative to the unstable electrical impedance tomography. In this paper, we analyze the existing mathematical models of this method, and propose a general procedure for solving the inverse problem associated with the MAET. It consists in applying to the data one of the algorithms of thermo-acoustic tomography, followed by solving the Neumann problem for the Laplace equation and the Poisson equation. For the particular case when the region of interest is a cube, we present an explicit series solution resulting in a fast reconstruction algorithm. As we show, both analytically and numerically, the MAET is a stable technique yielding high-resolution images even in the presence of significant noise in the data.

[1]  Leonid Kunyansky,et al.  Reconstruction of a function from its spherical (circular) means with the centers lying on the surface of certain polygons and polyhedra , 2010, 1009.0288.

[2]  David Isaacson,et al.  Electrical Impedance Tomography , 1999, SIAM Rev..

[3]  Eric Bonnetier,et al.  Electrical Impedance Tomography by Elastic Deformation , 2008, SIAM J. Appl. Math..

[4]  S. K. Patch,et al.  Thermoacoustic tomography: numerical results , 2007, SPIE BiOS.

[5]  B. Brown,et al.  Applied potential tomography. , 1989, Journal of the British Interplanetary Society.

[6]  Lihong V. Wang,et al.  Dark-Field Confocal Photoacoustic Microscopy , 2009 .

[7]  Peter Kuchment,et al.  Synthetic focusing in ultrasound modulated tomography , 2009, 0901.2552.

[8]  Minghua Xu,et al.  Time-domain reconstruction for thermoacoustic tomography in a spherical geometry , 2002, IEEE Transactions on Medical Imaging.

[9]  Y. Xu,et al.  Magneto-acousto-electrical tomography: a potential method for imaging current density and electrical impedance. , 2008, Physiological measurement.

[10]  Lihong V. Wang Photoacoustic imaging and spectroscopy , 2009 .

[11]  Frank K. Tittel,et al.  Laser-based optoacoustic imaging in biological tissues , 1994, SPIE LASE.

[12]  Linh V. Nguyen A family of inversion formulas in thermoacoustic tomography , 2009, 0902.2579.

[13]  D. Gilbarg,et al.  Elliptic Partial Differential Equa-tions of Second Order , 1977 .

[14]  Longitudinal and transverse components of a vector field , 2008, 0801.0335.

[15]  R. Kruger,et al.  Photoacoustic ultrasound (PAUS)--reconstruction tomography. , 1995, Medical physics.

[16]  Jérôme Fehrenbach,et al.  Imaging by Modification: Numerical Reconstruction of Local Conductivities from Corresponding Power Density Measurements , 2009, SIAM J. Imaging Sci..

[17]  Linh V. Nguyen,et al.  Reconstruction and time reversal in thermoacoustic tomography in acoustically homogeneous and inhomogeneous media , 2008 .

[18]  Leonid Kunyansky A series solution and a fast algorithm for the inversion of the spherical mean Radon transform , 2007 .

[19]  L. Kunyansky,et al.  Explicit inversion formulae for the spherical mean Radon transform , 2006, math/0609341.

[20]  Peter Kuchment,et al.  Uniqueness of reconstruction and an inversion procedure for thermoacoustic and photoacoustic tomography with variable sound speed , 2007, 0706.0598.

[21]  J Jossinet,et al.  Experimental measurement of the acousto-electric interaction signal in saline solution. , 2000, Ultrasonics.

[22]  R. Kress,et al.  Inverse Acoustic and Electromagnetic Scattering Theory , 1992 .

[23]  Bradley J. Roth,et al.  Ultrasonically-induced Lorentz force tomography , 2009, Medical & Biological Engineering & Computing.

[24]  V. S. Vladimirov,et al.  Equations of mathematical physics , 1972 .

[25]  M. Haltmeier,et al.  Exact and approximative imaging methods for photoacoustic tomography using an arbitrary detection surface. , 2007, Physical review. E, Statistical, nonlinear, and soft matter physics.

[26]  Lihong V. Wang,et al.  Acousto-electric tomography , 2004, SPIE BiOS.

[27]  J. Jossinet,et al.  Electric current generated by ultrasonically induced Lorentz force in biological media , 2006, Medical and Biological Engineering and Computing.

[28]  Peter Kuchment,et al.  2D and 3D reconstructions in acousto-electric tomography , 2010, 1011.3059.

[29]  Habib Ammari,et al.  Mathematical models and reconstruction methods in magneto-acoustic imaging , 2009, European Journal of Applied Mathematics.

[30]  Liliana Borcea,et al.  Electrical impedance tomography , 2002 .

[31]  J. Shah,et al.  Hall effect imaging , 1998, IEEE Transactions on Biomedical Engineering.

[32]  Stephen J. Norton,et al.  Ultrasonic Reflectivity Imaging in Three Dimensions: Exact Inverse Scattering Solutions for Plane, Cylindrical, and Spherical Apertures , 1981, IEEE Transactions on Biomedical Engineering.

[33]  Rakesh,et al.  Determining a Function from Its Mean Values Over a Family of Spheres , 2004, SIAM J. Math. Anal..

[34]  Leonid Kunyansky,et al.  Fast reconstruction algorithms for the thermoacoustic tomography in certain domains with cylindrical or spherical symmetries , 2011, 1102.1413.

[35]  R A Kruger,et al.  Thermoacoustic computed tomography--technical considerations. , 1999, Medical physics.