Computer Relaying for Power Systems

This text/reference presents a comprehensive, up-to-date account of computer relaying in power systems, based in part on the author's extensive experience in the field. Provides background material on current relaying practices, and covers the mathematical foundations for relaying algorithms. Each chapter contains helpful illustrations, examples, and problems.

[1]  G. Swift,et al.  The Spectra of Fault-Induced Transients , 1979, IEEE Transactions on Power Apparatus and Systems.

[2]  Stanley H. Horowitz,et al.  Protective Relaying for Power Systems , 1981 .

[3]  Alan V. Oppenheim,et al.  Discrete-Time Signal Pro-cessing , 1989 .

[4]  G. D. Rockefeller,et al.  Fault Protection with a Digital Computer , 1969 .

[5]  I. F. Morrison,et al.  A Proposed Method of Harmonic Restraint Differential Protecting of Transformers by Digital Computer , 1972 .

[6]  F. Harris On the use of windows for harmonic analysis with the discrete Fourier transform , 1978, Proceedings of the IEEE.

[7]  W.C. Kotheimer,et al.  Electromagnetic interference and solid state protective relays , 1977, IEEE Transactions on Power Apparatus and Systems.

[8]  A. G. Phadke,et al.  A New Computer-Based Flux-Restrained Current-Differential Relay for Power Transformer Protection , 1983, IEEE Power Engineering Review.

[9]  M. A. Marin,et al.  A comparative analysis of digital relaying algorithms for the differential protection of three phase transformers , 1988 .

[10]  T. Hlibka,et al.  A Microcomputer Based Ultra-High-Speed Dostance Relay: Field Tests , 1981, IEEE Transactions on Power Apparatus and Systems.

[11]  Virgilio A Centeno Mimic circuit simulation in real time , 1988 .

[12]  Edith Clarke,et al.  Circuit analysis of A-C power systems , 1950 .

[13]  C. R. Mason,et al.  The Art and Science of Protective Relaying , 1956 .

[14]  Gabriel Benmouyal An Adaptive Sampling-Interval Generator for Digital Relaying , 1989, IEEE Power Engineering Review.

[15]  T. Hlibka,et al.  Fundamental basis for distance relaying with symmetrical components , 1977, IEEE Transactions on Power Apparatus and Systems.

[16]  W.D. Breingan,et al.  The Laboratory Investigation of a Digital System for the Protection of Transmission Lines , 1979, IEEE Transactions on Power Apparatus and Systems.

[17]  A. G. Phadke,et al.  A microprocessor based bus relay using a current transformer saturation detector , 1990, Proceedings of the Twenty-Second Annual North American Power Symposium.

[18]  I. F. Morrison,et al.  Digital Calculation of Impedance for Transmission Line Protection , 1971 .

[19]  M. S. Sachdev,et al.  Generator Differential Protection Using a Hybrid Computer , 1973 .

[20]  A.M. Ranjbar,et al.  An improved method for the digital protection of high voltage transmission lines , 1975, IEEE Transactions on Power Apparatus and Systems.

[21]  James S. Thorp,et al.  A Microprocessor Based Three-Phase Transformer Differential Relay , 1982 .

[22]  M.S. Sachdev,et al.  Kalman Filtering Applied to Power System Measurements Relaying , 1985, IEEE Transactions on Power Apparatus and Systems.

[23]  E. L. Harder,et al.  Principles and Practices of Relaying in the United States , 1948, Transactions of the American Institute of Electrical Engineers.

[24]  A.G. Phadke,et al.  Limits to Impedance Relaying , 1979, IEEE Transactions on Power Apparatus and Systems.

[25]  W. Smolinski An Algorithm for Digital Impedance Calculation Using a Single PI Section Transmission Line Model , 1979, IEEE Transactions on Power Apparatus and Systems.

[26]  Adly Girgis,et al.  Application of Kalman Filtering in Computer Relaying , 1981, IEEE Transactions on Power Apparatus and Systems.