Adaptive ranging for optical coherence tomography.

At present, optical coherence tomography systems have a limited imaging depth or axial scan range, making diagnosis of large diameter arterial vessels and hollow organs difficult. Adaptive ranging is a feedback technique where image data is utilized to adjust the coherence gate offset and range. In this paper, we demonstrate an adaptive optical coherence tomography system with a 7.0 mm range. By matching the imaging depth to the approximately 1.5 mm penetration depth in tissue, a 3 dB sensitivity improvement over conventional imaging systems with a 3.0 mm imaging depth was realized.

[1]  E. Halpern,et al.  Quantification of Macrophage Content in Atherosclerotic Plaques by Optical Coherence Tomography , 2003, Circulation.

[2]  A. Fercher,et al.  Dynamic coherent focus OCT with depth-independent transversal resolution , 1999 .

[3]  G. Ripandelli,et al.  Optical coherence tomography in the evaluation of vitreoretinal disorders of the macula in highly myopic eyes , 2003, Seminars in ophthalmology.

[4]  J. Fujimoto,et al.  High-speed phase- and group-delay scanning with a grating-based phase control delay line. , 1997, Optics letters.

[5]  B. Bouma,et al.  Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography. , 1999, Optics letters.

[6]  W. Janowitz,et al.  Coronary artery diameter and coronary risk factors: a study with ultrafast computed tomography. , 1993, American heart journal.

[7]  C. Compton,et al.  High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography. , 2000, Gastrointestinal endoscopy.

[8]  B E Bouma,et al.  Images in cardiovascular medicine. Catheter-based optical imaging of a human coronary artery. , 1996, Circulation.

[9]  J. Kauppinen,et al.  Fourier Transforms in Spectroscopy , 2001 .

[10]  E. Halpern,et al.  Characterization of Human Atherosclerosis by Optical Coherence Tomography , 2002, Circulation.

[11]  J. Izatt,et al.  Optical coherence microscopy in gastrointestinal tissues , 1996, Summaries of papers presented at the Conference on Lasers and Electro-Optics.

[12]  I. Alex Vitkin,et al.  Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror , 2004 .

[13]  J M Schmitt,et al.  Subsurface imaging of living skin with optical coherence microscopy. , 1995, Dermatology.

[14]  J. Izatt,et al.  Optical Coherence Tomography and Microscopy in Gastrointestinal Tissues , 1996, Advances in Optical Imaging and Photon Migration.

[15]  J. Fujimoto,et al.  In vivo retinal imaging by optical coherence tomography. , 1993, Optics letters.

[16]  Michael Larsen,et al.  Diabetic macular edema assessed with optical coherence tomography and stereo fundus photography. , 2002, Investigative ophthalmology & visual science.

[17]  Barry Cense,et al.  Real-time multi-functional optical coherence tomography. , 2003, Optics express.

[18]  Barry Cense,et al.  In vivo birefringence and thickness measurements of the human retinal nerve fiber layer using polarization-sensitive optical coherence tomography. , 2004, Journal of biomedical optics.

[19]  M. Brezinski Optical Coherence Tomography: Principles and Applications , 2006 .

[20]  J. Izatt,et al.  High-resolution endoscopic imaging of the GI tract using optical coherence tomography. , 2000, Gastrointestinal endoscopy.

[21]  S A Boppart,et al.  High-resolution imaging of gynecologic neoplasms using optical coherence tomography. , 1999, Obstetrics and gynecology.