Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions.
暂无分享,去创建一个
L. See | K. Ng | K. Lui | K. Yeow | H P Liu | T C Tsao | K M Yeow | L C See | K W Lui | M C Lin | K F Ng | H. P. Liu | M. Lin | Thomas Chang-Yao Tsao | T. Tsao | K. Ng | H. Liu | Meng-Chih Lin | Hui-Ping Liu
[1] François Laurent,et al. Percutaneous CT-Guided Biopsy of the Lung: Comparison Between Aspiration and Automated Cutting Needles Using a Coaxial Technique , 2000, CardioVascular and Interventional Radiology.
[2] V Latrabe,et al. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. , 2000, Clinical radiology.
[3] R. Choplin,et al. Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax. , 1999, Radiology.
[4] V Latrabe,et al. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. , 1999, AJR. American journal of roentgenology.
[5] J. Klein,et al. Special techniques in CT-guided transthoracic needle biopsy. , 1998, AJR. American journal of roentgenology.
[6] S. H. Park,et al. Pneumothorax size: correlation of supine anteroposterior with erect posteroanterior chest radiographs. , 1998, Radiology.
[7] M. Herskowitz,et al. Insignificance of small loculated pneumothoraces after core biopsies of peripheral lung lesions using the Temno biopsy needle. , 1998, AJR. American journal of roentgenology.
[8] E. Moore,et al. Technical aspects of needle aspiration lung biopsy: a personal perspective. , 1998, Radiology.
[9] T. McLoud. Should cutting needles replace needle aspiration of lung lesions? , 1998, Radiology.
[10] O Lucidarme,et al. Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle. , 1998, Radiology.
[11] Ruizong Li,et al. Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions. , 1998, Journal of vascular and interventional radiology : JVIR.
[12] T. Sonomura,et al. ``Oblique Path''— The Optimal Needle Path for Computed Tomography-Guided Biopsy of Small Subpleural Lesions , 1996, CardioVascular and Interventional Radiology.
[13] C. Henschke,et al. Aspiration of a large pneumothorax resulting from transthoracic needle biopsy. , 1996, Radiology.
[14] G. Salomon,et al. Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. , 1996, Radiology.
[15] F. Martinez,et al. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. , 1996, Radiology.
[16] M. Roddie,et al. Quantification of pneumothorax size on chest radiographs using interpleural distances: regression analysis based on volume measurements from helical CT. , 1995, AJR. American journal of roentgenology.
[17] P. T. Moore,et al. Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. , 1993, Radiology.
[18] T. McLoud,et al. Effect of patient positioning after needle aspiration lung biopsy. , 1991, Radiology.
[19] P. Friedman,et al. Difficult thoracic lesions: CT-guided biopsy experience in 150 cases. , 1988, Radiology.
[20] K. Miller,et al. Prediction of pneumothorax rate in percutaneous needle aspiration of the lung. , 1988, Chest.
[21] S. Schabel,et al. Lung lesions: cytologic diagnosis by fine-needle biopsy. , 1987, Radiology.
[22] G. E. Newman,et al. Timing of chest film follow-up after transthoracic needle aspiration. , 1986, AJR. American journal of roentgenology.
[23] W. E. Miller,et al. Transthoracic needle biopsy: accuracy and complications in relation to location and type of lesion. , 1980, Mayo Clinic proceedings.
[24] R. E. Clark,et al. Percutaneous transthoracic aspiration needle biopsy. , 1978, The Annals of thoracic surgery.
[25] N. Patt,et al. Fatal pulmonary hemorrhage after percutaneous aspiration lung biopsy. , 1974, The American review of respiratory disease.
[26] R. Norenberg,et al. Percutaneous needle biopsy of the lung: report of two fatal complications. , 1974, Chest.
[27] J. Dyer,et al. Image-guided automated needle biopsy of 106 thoracic lesions: a retrospective review of diagnostic accuracy and complication rates , 2000, European Radiology.
[28] R. Spira. Chest CT for detection of pneumothorax after lung biopsy. , 1998, AJR. American journal of roentgenology.
[29] J. Westcott,et al. Transthoracic needle biopsy of small pulmonary nodules. , 1997, Radiology.