A sensitive and selective on-line amperometric sulfite biosensor using sulfite oxidase immobilized on a magnetite-gold-folate nanocomposite modified carbon-paste electrode.

We describe a novel amperometric sulfite biosensor, comprising a carbon-paste electrode (Fe3O4@Au-Cys-FA/CPE) modified with immobilized sulfite oxidase (SOx) on a gold-coated magnetite nanoparticle core, encased within a conjugated folic acid (FA) cysteine (Cys) shell. The biosensor electrode was fabricated using a polydimethylsiloxane (PDMS) and mineral oil mixture as binder, which also enhances the physical stability and sensitivity of the electrode. The developed biosensor displays good electrocatalytic activity toward oxidation of H2O2, which occurs by an enzymatic reaction between SOx and sulfite. The Fe3O4@Au-Cys-FA electrode exhibits good electrocatalytic activity, and has good retention of chemisorbed SOx on the electrode because of its large surface area. Sulfite was quantified using amperometric measurements from the Fe3O4@Au-Cys-FA/CPE biosensor, and using an in-house assembled flow cell at +0.35V (vs. Ag/AgCl), with a phosphate buffer carrier (0.10M, pH 7.0) at a flow rate of 0.8mLmin(-1). The system detects sulfite over the range 0.1-200mgL(-1) (r(2)=0.998), with a detection limit of 10µgL(-1) (3σ of blank). The system exhibits acceptable precision (%R.S.D.=3.1%), rapid sample throughput (109samplesh(-1)), and good stability (2w). The developed biosensor shows satisfactory tolerance to potential interferences, such as sugars, anions, ascorbic acid, and ethanol. We applied the developed method to the determination of sulfite content in wines and pickled food extracts, and our results are in good agreement with those obtained by the standard iodometric method.

[1]  Orawon Chailapakul,et al.  An Electrochemical Compact Disk-type Microfluidics Platform for Use as an Enzymatic Biosensor , 2015 .

[2]  Osama M Mustafa Magnetic , 2016, Medical Humanities.

[3]  I. Boyaci,et al.  Synthesis of magnetic core–shell Fe3O4–Au nanoparticle for biomolecule immobilization and detection , 2010 .

[4]  G. Somer,et al.  Determination of trace sulfite by direct and indirect methods using differential pulse polarography. , 2007, Analytica chimica acta.

[5]  Jin Luo,et al.  Monodispersed core-shell Fe3O4@Au nanoparticles. , 2005, The journal of physical chemistry. B.

[6]  Ulla Wollenberger,et al.  Effective Electrochemistry of Human Sulfite Oxidase Immobilized on Quantum-Dots-Modified Indium Tin Oxide Electrode. , 2015, ACS applied materials & interfaces.

[7]  J. Moura,et al.  Biosensing nitrite using the system nitrite redutase/Nafion/methyl viologen--a voltammetric study. , 2007, Biosensors & bioelectronics.

[8]  M. A. Alonso-Lomillo,et al.  Sulfite oxidase biosensors based on tetrathiafulvalene modified screen-printed carbon electrodes for sulfite determination in wine. , 2014, Analytica chimica acta.

[9]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[10]  C. Pundir,et al.  Determination of sulfite with emphasis on biosensing methods: a review , 2013, Analytical and Bioanalytical Chemistry.

[11]  R. Ramaraj,et al.  Photoreduction of dioxygen to hydrogen peroxide at porphyrins and phthalocyanines adsorbed Nafion membrane , 1999 .

[12]  Frieder W. Scheller,et al.  Electrocatalytic sulfite biosensor with human sulfite oxidase co-immobilized with cytochrome c in a polyelectrolyte-containing multilayer , 2008, Analytical and bioanalytical chemistry.

[13]  S. Liawruangrath,et al.  Pervaporation flow injection analysis for the determination of sulphite in food samples utilising potassium permanganate–rhodamine B chemiluminescence detection , 2010 .

[14]  Tanin Tangkuaram,et al.  Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode. , 2010, Talanta.

[15]  Kurt Kalcher,et al.  Flow-injection amperometric determination of glucose using a biosensor based on immobilization of glucose oxidase onto Au seeds decorated on core Fe₃O₄ nanoparticles. , 2015, Talanta.

[16]  M. Amatatongchai,et al.  Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles. , 2015, Talanta.

[17]  T. Tzanov,et al.  Voltammetric monitoring of laccase-catalysed mediated reactions. , 2002, Bioelectrochemistry.

[18]  Eric R. Ziegel,et al.  Statistics and Chemometrics for Analytical Chemistry , 2004, Technometrics.

[19]  R. Compton,et al.  Electroanalytical methods for the determination of sulfite in food and beverages , 2006 .

[20]  M. Amatatongchai,et al.  Rapid Screening Method for Assessing Total Phenolic Content Using Simple Flow Injection System with Laccase based- biosensor , 2013 .

[21]  C. Sangregorio,et al.  Magnetic, optical and relaxometric properties of organically coated gold–magnetite (Au–Fe3O4) hybrid nanoparticles for potential use in biomedical applications , 2012 .

[22]  Kang Li,et al.  Fe2O3@Au core/shell nanoparticle-based electrochemical DNA biosensor for Escherichia coli detection. , 2011, Talanta.

[23]  S. Elliott,et al.  A voltammetric study of interdomain electron transfer within sulfite oxidase. , 2002, Journal of the American Chemical Society.

[24]  Mustafa Kemal Sezgintürk,et al.  Sulfite determination using sulfite oxidase biosensor based glassy carbon electrode coated with thin mercury film , 2007 .

[25]  J. Irudayaraj,et al.  Examination of Cholesterol oxidase attachment to magnetic nanoparticles , 2005, Journal of nanobiotechnology.

[26]  S. Hassan,et al.  A novel spectrophotometric method for batch and flow injection determination of sulfite in beverages. , 2006, Analytica chimica acta.

[27]  John P. Hart,et al.  Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer , 2000 .

[28]  C. Brett,et al.  Simple electrochemical sensor for caffeine based on carbon and Nafion-modified carbon electrodes. , 2014, Food chemistry.

[29]  C. Pundir,et al.  Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode , 2011, Analytical and bioanalytical chemistry.

[30]  Xuzhou Chen,et al.  A Magnetic-Controlled Amperometric Biosensor Based on Composite Bio-Particulates Fe3O4 and Nano-Au With The Signal Enhancement by Increasing Loading of Horseradish Peroxidase , 2011, International Journal of Electrochemical Science.

[31]  W. Horwitz,et al.  Official methods of analysis of AOAC International , 2010 .

[32]  Tronc,et al.  Size Tailoring of Magnetite Particles Formed by Aqueous Precipitation: An Example of Thermodynamic Stability of Nanometric Oxide Particles. , 1998, Journal of colloid and interface science.

[33]  O. Fatibello‐Filho,et al.  Flow injection spectrophotometric determination of sulfite using a crude extract of sweet potato root (Ipomoea batatas (L.) Lam.) as a source of polyphenol oxidase , 1997 .

[34]  M. Amatatongchai,et al.  Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode. , 2017, Talanta.

[35]  W. L. Robb,et al.  THIN SILICONE MEMBRANES‐THEIR PERMEATION PROPERTIES AND SOME APPLICATIONS , 1968, Annals of the New York Academy of Sciences.

[36]  Charles S Henry,et al.  Poly(dimethylsiloxane) cross-linked carbon paste electrodes for microfluidic electrochemical sensing. , 2011, The Analyst.

[37]  R. F. Mcfeeters,et al.  Sulfite analysis of fruits and vegetables by high-performance liquid chromatography (HPLC) with ultraviolet spectrophotometric detection. , 2003, Journal of agricultural and food chemistry.

[38]  M. Sadjadi,et al.  Fabrication and spectroscopic studies of folic acid-conjugated Fe3O4@Au core-shell for targeted drug delivery application. , 2015, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[39]  E. Somsook,et al.  Poly(m-ferrocenylaniline) modified carbon nanotubes-paste electrode encapsulated in nafion film for selective and sensitive determination of dopamine and uric acid in the presence of ascorbic acid , 2016 .

[40]  M. Aguirre,et al.  Nafion/tetraruthenated porphyrin glassy carbon-modified electrode: characterization and voltammetric studies of sulfite oxidation in water–ethanol solutions , 2010 .

[41]  Shengyong Yan,et al.  A new fluorescent turn-on probe for highly sensitive and selective detection of sulfite and bisulfite , 2014 .

[42]  U. Wollenberger,et al.  Human sulfite oxidase electrochemistry on gold nanoparticles modified electrode. , 2012, Bioelectrochemistry.

[43]  Yuming Huang,et al.  CoFe2O4 nanoparticles as oxidase mimic-mediated chemiluminescence of aqueous luminol for sulfite in white wines. , 2013, Journal of agricultural and food chemistry.

[44]  Joseph Wang,et al.  Oxygen-independent poly(dimethylsiloxane)-based carbon-paste glucose biosensors. , 2002, Biosensors & bioelectronics.

[45]  J. Švitel,et al.  Composite Biosensor for Sulfite Assay: Use of Water-Insoluble Hexacyanoferrate(III) Salts as Electron-Transfer Mediators , 1998 .

[46]  A. Ensafi,et al.  Ferrocenedicarboxylic Acid Modified Multiwall Carbon Nanotubes Paste Electrode for Voltammetric Determination of Sulfite , 2010, International Journal of Electrochemical Science.

[47]  L. Vogler Lehninger Principles Of Biochemistry 5th Edition , 2016 .

[48]  Chandra Shekhar Pundir,et al.  An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode. , 2012, Biosensors & bioelectronics.