Biosensor systems for pesticide determination in water

Different biosensor systems suitable for the determination of pesticides in water are described. They are based on immobilized biological components, which are sensitive to compounds commonly used as pesticides. The biological components in the work described here were microorganisms capable of degrading chlorinated aromatic compounds, cholinesterases which are inhibited by carbamates and organophosphates, and antibodies specific to triazines. They were immobilized on various carriers and were either integrated in automated flow-through systems or developed as disposable electrodes. In this contribution, characteristics features of the different formats are given, e.g., the dependence of the specificity and sensitivity of the system on the biological component.

[1]  Frieder W. Scheller,et al.  A fast estimation of biochemical oxygen demand using microbial sensors , 1988, Applied Microbiology and Biotechnology.

[2]  Juozas Kulys,et al.  Printed amperometric sensor based on TCNQ and cholinesterase , 1991 .

[3]  B. Hock,et al.  ELISAS ZUR BESTIMMUNG VON ATRAZIN UND ATRAZIN-METABOLITEN IN WASSER , 1990 .

[4]  M. Böcher,et al.  Use of a fibre optic immunosensor for the detection of pesticides , 1992 .

[5]  Rolf D. Schmid,et al.  Exchangeable immobilized enzyme reactor for enzyme inhibition tests in flow-injection analysis using a magnetic device. Determination of pesticides in drinking water , 1990 .

[6]  B. Hock Enzyme Immunoassays for the Determination of s-Triazines in Water Samples: Two Interlaboratory Tests , 1991 .

[7]  K. Quentin,et al.  Bestimmung von Phosphorpestiziden und insektiziden Carbamaten mittels Cholinesterasehemmung. II, Abschätzung von Nachweisgrenzen der Insektizidbestimmung durch Anreicherung, Oxidation und Hemmwirkung , 1990 .

[8]  J. Nicaud,et al.  Detection of organophosphorous pesticides with an immobilized cholinesterase electrode. , 1984, Journal of analytical toxicology.

[9]  K. Courtney,et al.  A new and rapid colorimetric determination of acetylcholinesterase activity. , 1961, Biochemical pharmacology.

[10]  R. Schmid,et al.  Automated quasi-continuous immunoanalysis of pesticides with a flow injection system† , 1991 .

[11]  T. Giersch,et al.  Production of monoclonal antibodies for the determination of s‐triazines with enzyme immunoassays , 1990 .

[12]  A. Tanaka,et al.  Application of Biocatalysts Immobilized by Prepolymer Methods , 1984, Immobilized Biocatalysts, Saccharomyces Yeasts, Wastewater Treatment.

[13]  Ursula Bilitewski,et al.  Miniaturized disposable biosensors , 1992 .