Dynamic security issues in autonomous power systems with increasing wind power penetration

Abstract Technical requirements set by the network operators nowadays include various aspects, such as fault ride-through capability of wind turbines during faults, voltage-reactive power control and overall control of the wind farms as conventional power plants. Detailed models for the power system as well as for the wind farms are therefore essential for power system studies related to these issues, especially when applied to non interconnected systems with high wind power penetration. Detailed generic models for three different wind turbine technologies – Active Stall Induction Generator (ASIG), Doubly Fed Asynchronous Generator (DFAG) and Permanent Magnet Synchronous Generator (PMSG) – are applied and issues regarding interaction with the power system are investigated. This paper provides conclusions about the dynamic security of non-interconnected power systems with high wind power penetration based on a complete model representation of the individual components of the system; three different types of conventional generators are included in the model, while the protection system is also incorporated. The load shedding following faults is finally discussed.

[1]  Poul Ejnar Sørensen,et al.  Centralised power control of wind farm with doubly fed induction generators , 2006 .

[2]  Anca Daniela Hansen,et al.  Fault ride-through capability of DFIG wind turbines , 2007 .

[3]  N. D. Hatziargyriou,et al.  Methods for evaluating penetration levels of wind generation in autonomous systems , 2009, 2009 IEEE Bucharest PowerTech.

[4]  Anca Daniela Hansen,et al.  Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults , 2009 .

[5]  Boon-Teck Ooi,et al.  Frequency deviation of thermal power plants due to wind farms , 2006, IEEE Transactions on Energy Conversion.

[6]  V. Akhmatov Analysis of Dynamic Behaviour of Electric Power Systems with Large Amount of Wind Power , 2003 .

[7]  P. Sorensen,et al.  Power Fluctuations From Large Wind Farms , 2007, IEEE Transactions on Power Systems.

[8]  N. D. Hatziargyriou,et al.  On-Line Preventive Dynamic Security of Isolated Power Systems Using Decision Trees , 2002, IEEE Power Engineering Review.

[9]  Anca Daniela Hansen,et al.  Modelling and control of variable-speed multi-pole permanent magnet synchronous generator wind turbine , 2008 .

[10]  S. Achilles,et al.  Aggregated Wind Park Models for Analyzing Power System Dynamics , 2003 .

[11]  Z.A. Styczynski,et al.  Dynamic simulation of renewable energy sources and requirements on fault ride through behavior , 2006, 2006 IEEE Power Engineering Society General Meeting.

[12]  N. Jenkins,et al.  Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency , 2004, IEEE Transactions on Energy Conversion.

[13]  Poul Ejnar Sørensen,et al.  Co-ordinated voltage control of DFIG wind turbines in uninterrupted operation during grid faults , 2007 .

[14]  Nicholas Jenkins,et al.  Frequency support from doubly fed induction generator wind turbines , 2007 .

[15]  Nicholas Jenkins,et al.  Power system frequency response from fixed speed and doubly fed induction generator-based wind turbines , 2004 .

[16]  A.H. Kasem,et al.  A New Fault Ride-through Strategy for Doubly Fed Wind-Power Induction Generator , 2007, 2007 IEEE Canada Electrical Power Conference.

[17]  Poul Ejnar Sørensen,et al.  Simulation Model of an Active-Stall Fixed-Speed Wind Turbine Controller , 2004 .

[18]  K. Uhlen,et al.  Control concepts to enable increased wind power penetration , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[19]  N. Kakimoto,et al.  Performance of gas turbine-based plants during frequency drops , 2003 .

[20]  Poul Ejnar Sørensen,et al.  Impact of wind power in autonomous power systems—power fluctuations—modelling and control issues , 2011 .

[21]  Niels Kjølstad Poulsen,et al.  Modelling and transient stability of large wind farms , 2003 .

[22]  Poul Ejnar Sørensen,et al.  Control design for a pitch-regulated, variable speed wind turbine , 2005 .

[23]  Fulli Gianluca,et al.  Grid Connection of Large Wind Power Plants - a European Overview , 2009 .

[24]  Antonio Vigueras-Rodríguez,et al.  Modelling of power fluctuations from large offshore wind farms , 2008 .