Gamma‐Ray Computed Tomography for Imaging of Multiphase Flows

Multiphase flows are omnipresent in the chemical industry. The flow phenomena in multiphase reactors strongly affect the processes performance. Nonetheless, even basic information on flow patterns, flow regimes and effects of internals etc. is often not available, which is a strong obstacle for a reliable design and scale-up. Non-invasive tomographic techniques are promising measurement tools to visualize opaque multiphase flows. The contribution provides a short survey about today's tomographic imaging techniques and introduces the principles of radiation-based tomography. In particular, two gamma-ray computed tomography designs and their application for sparger performance study in large bubble columns and for flow regime determination in inclined rotating fixed-bed reactors are presented.

[1]  F. A. Kulacki,et al.  Design of an Isotopic CT Scanner for Two Phase Flow Measurements , 1980, IEEE Transactions on Nuclear Science.

[2]  Uwe Hampel,et al.  Design of a high-resolution gamma-ray detector module for tomography applications , 2007 .

[3]  Wuqiang Yang,et al.  Hardware design of electrical capacitance tomography systems , 1996 .

[4]  Jyeshtharaj B. Joshi,et al.  Gas hold-up profiles in foaming liquids in bubble columns , 2001 .

[5]  Gabriel Wild,et al.  Influence of gas distribution and regime transitions on liquid velocity and turbulence in a 3-D bubble column , 2001 .

[6]  Gabriel Wild,et al.  Measuring techniques in gas–liquid and gas–liquid–solid reactors , 2002 .

[7]  Markus Schubert,et al.  Unsteady-state operation of trickle-bed reactors , 2004 .

[8]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[9]  Markus Schubert,et al.  Hydrodynamische Charakterisierung eines Gas/flüssig-durchströmten geneigten Festbettdrehrohrreaktors , 2012 .

[10]  R. F. Mudde,et al.  Time-Resolved γ-Densitometry Imaging within Fluidized Beds , 2005 .

[11]  Jyeshtharaj B. Joshi,et al.  Design and selection of sparger for bubble column reactor. Part I: Performance of different spargers , 2011 .

[12]  Dominique Toye,et al.  Imaging of liquid distribution in reactive distillation packings with a new high-energy x-ray tomograph , 2005 .

[13]  U. Hampel,et al.  An ultra fast electron beam x-ray tomography scanner , 2008 .

[14]  Uwe Hampel,et al.  Measurement of Liquid Distributions in Particle Packings Using Wire-Mesh Sensor versus Transmission Tomographic Imaging , 2010 .

[15]  Lynn F. Gladden,et al.  Determination of bed voidage using water substitution and 3D magnetic resonance imaging, bed density and pressure drop in packed-bed reactors , 2001 .

[16]  Markus Schubert,et al.  Instationäre Betriebsweise zur Leistungssteigerung technischer Rieselbettreaktoren , 2006 .

[17]  Sailesh Kumar,et al.  A γ-ray tomographic scanner for imaging voidage distribution in two-phase flow systems , 1995 .

[18]  Uwe Hampel,et al.  Design of a modular signal processing board (MSPB) for gamma-ray imaging applications , 2012 .

[19]  Patrick L. Mills,et al.  Multiphase catalytic reactors: a perspective on current knowledge and future trends , 2002 .

[20]  Jyeshtharaj B. Joshi,et al.  CFD simulation of sparger design and height to diameter ratio on gas hold-up profiles in bubble column reactors , 2004 .

[21]  Uwe Hampel,et al.  Application of high-resolution gamma ray tomography to the measurement of gas hold-up distributions in a stirred chemical reactor , 2007 .

[22]  Peter L. Silveston,et al.  Hydrogenation of crotonaldehyde under periodic flow interruption in a trickle bed , 1999 .

[23]  Trevor A. York Status of electrical tomography in industrial applications , 2001, J. Electronic Imaging.

[24]  F. J. Dickin,et al.  Chapter 5 – Impedance sensors — conducting systems , 1995 .

[25]  S. Becker,et al.  Modelling and simulation of the dynamic flow behaviour in a bubble column , 2001 .

[26]  Uwe Hampel,et al.  Advanced Tomographic Techniques for Flow Imaging in Columns with Flow Distribution Packings , 2011 .

[27]  Uwe Hampel,et al.  Tomography measurements of gas holdup in rotating foam reactors with Newtonian, non-Newtonian and foaming liquid , 2011 .

[28]  Uwe Hampel,et al.  Measurement of Fluid Distributions in a Rotating Fluid Coupling Using High Resolution Gamma Ray Tomography , 2008 .

[29]  Louis J. Thibodeaux,et al.  Bubble Column Reactors for Wastewater Treatment. 2. The Effect of Sparger Design on Sublation Column Hydrodynamics in the Homogeneous Flow Regime , 1996 .

[30]  Colin Ramshaw,et al.  The opportunities for exploiting centrifugal fields , 1993 .

[31]  Anastasios J. Karabelas,et al.  Liquid distribution in horizontal axially rotated packed beds , 1993 .

[32]  J. Chaouki,et al.  Noninvasive Tomographic and Velocimetric Monitoring of Multiphase Flows , 1997 .

[33]  F. Zimmermann,et al.  High resolution gamma ray tomography scanner for flow measurement and non-destructive testing applications. , 2007, The Review of scientific instruments.

[34]  Uwe Hampel,et al.  Temperature control design for a high-resolution gamma-ray tomography detector. , 2010, The Review of scientific instruments.

[35]  Lynn F. Gladden,et al.  Nuclear magnetic resonance in chemical engineering: Principles and applications , 1994 .

[36]  Uwe Hampel,et al.  Void measurement using high-resolution gamma-ray computed tomography , 2011 .

[37]  Ashfaq Shaikh,et al.  Characterization of the hydrodynamic flow regime in bubble columns via computed tomography , 2005 .

[38]  Milorad P. Dudukovic,et al.  Parametric study of unsteady-state flow modulation in trickle-bed reactors , 1999 .

[39]  Bhaskar N. Thorat,et al.  Gamma ray tomography—An experimental analysis of fractional gas hold-up in bubble columns , 2008 .

[40]  P. L. Silveston,et al.  Challenges for the periodic operation of trickle-bed catalytic reactors , 2002 .

[41]  Michael Schlüter,et al.  Lokale Messverfahren für Mehrphasenströmungen , 2011 .

[42]  S. Kamata,et al.  High energy X-ray computed tomography for industrial applications , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[43]  Christophe Boyer,et al.  Measurement of liquid flow distribution in trickle bed reactor of large diameter with a new gamma-ray tomographic system , 2002 .

[44]  Uwe Hampel,et al.  Liquid flow texture analysis in trickle bed reactors using high-resolution gamma ray tomography , 2008 .

[45]  Timothy J. O'Hern,et al.  Gamma-densitometry tomography of gas holdup spatial distribution in industrial-scale bubble columns , 1995 .

[46]  B. T. Hjertaker,et al.  A dual sensor flow imaging tomographic system , 1996 .