An iridium oxide reference electrode for use in microfabricated biosensors and biochips.

In this paper we argue for the use of iridium oxide (IrO(x)) electrodes as quasi-reference electrodes in microfabricated biosensors and biochips that operate in buffered solutions. The simple microfabrication of these electrodes consists of a one-step electrodeposition of IrO(x) onto a microfabricated platinum (Pt) electrode. The IrO(x) electrode potential was found to vary less than 20 mV over 9 days after stabilization for 1 day in a phosphate-buffered saline (PBS) solution; this behavior of the electrode potential was found to be easily reproduced. Moreover, the electrode potential was found to vary by less than 15 mV in the initial hour of its use; this behavior of the electrode potential was also found to be reproducible. The performance of a microfabricated glucose sensor employing an IrO(x) reference electrode is characterized in this paper in order to evaluate the usefulness of this new IrO(x) electrode as a quasi-reference electrode. The glucose sensor consists of a recessed microfabricated Pt electrode array, an electrodeposited IrO(x) film, an inner layer composed of an electropolymerized poly(m-phenylenediamine)/glucose oxidase (PMPD/GOx) film, and an outer or protective layer composed of Teflon and polyurethane (PU) films. The response of this sensor was found to be equivalent to the response of the same sensor employing a commercial Ag/AgCl reference electrode. These results show that a microfabricated IrO(x) electrode can be used as a quasi-reference electrode in microfabricated biosensors and biochips operating in buffered solutions.

[1]  W. Cascio,et al.  Measurement of extracellular pH, K(+), and lactate in ischemic heart. , 2002, Analytical biochemistry.

[2]  C. Choi,et al.  Glucose sensor using a microfabricated electrode and electropolymerized bilayer films. , 2002, Biosensors & bioelectronics.

[3]  D. J. Harrison,et al.  Prevention of the rapid degradation of subcutaneously implanted Ag/AgCl reference electrodes using polymer coatings. , 1994, Analytical chemistry.

[4]  P. Kulesza,et al.  Electrode processes and charge transport in bulk redox conducting inorganic solids , 1997 .

[5]  Isao Karube,et al.  Problems associated with the thin-film Ag/AgCl reference electrode and a novel structure with improved durability , 1998 .

[6]  James D. Weiland,et al.  Chronic neural stimulation with thin-film, iridium oxide electrodes , 2000, IEEE Trans. Biomed. Eng..

[7]  M. Koudelka-Hep,et al.  Thin-film microfabrication of electrochemical transducers , 1998 .

[8]  Plamen Atanasov,et al.  Development of needle-type glucose sensor with high selectivity , 1998 .

[9]  Tian C Zhang,et al.  Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies. , 2002, Analytical chemistry.

[10]  Sheng Yao,et al.  A long-term stable iridium oxide pH electrode , 2002 .

[11]  A novel thin-film Ag/AgCl anode structure for microfabricated Clark-type oxygen electrodes , 1998 .

[12]  Marc Madou,et al.  Electrochemical Measurements on Pt, Ir, and Ti Oxides as pH Probes , 1984 .

[13]  N. Ito,et al.  Development of a micro-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor , 2002 .

[14]  Isao Karube,et al.  Micromachined liquid-junction Ag/AgCl reference electrode , 1998 .

[15]  G. S. Wilson,et al.  Electrochemical oxidation of H2O2 on Pt and Pt + Ir electrodes in physiological buffer and its applicability to H2O2-based biosensors , 1993 .

[16]  Godfrey L. Smith,et al.  Ultra-low-volume, real-time measurements of lactate from the single heart cell using microsystems technology. , 2002, Analytical chemistry.

[17]  I-Yu Huang,et al.  Fabrication and characterization of a new planar solid-state reference electrode for ISFET sensors , 2002 .

[18]  Patrick J. Kinlen,et al.  A solid-state pH sensor based on a Nafion-coated iridium oxide indicator electrode and a polymer-based silver chloride reference electrode , 1994 .

[19]  Wipf,et al.  Microscopic measurement of pH with iridium oxide microelectrodes , 2000, Analytical chemistry.

[20]  I Karube,et al.  Micromachined severinghaus-type carbon dioxide electrode. , 1999, Analytical chemistry.

[21]  J. Baur,et al.  Electrochemical deposition of iridium (IV) oxide from alkaline solutions of iridium(III) oxide , 1998 .

[22]  S. D. Collins,et al.  Practical limits for solid-state reference electrodes , 1993 .

[23]  C.C. Liu,et al.  Fabricating biomedical sensors with thin-film technology , 1994, IEEE Engineering in Medicine and Biology Magazine.

[24]  Dermot Diamond,et al.  Evaluation of miniaturised solid state reference electrodes on a silicon based component , 1997 .

[25]  J. Florkey,et al.  From batch to continuous manufacturing of microbiomedical devices. , 2000, Chemical reviews.

[26]  Buffle,et al.  Voltammetric and reference microelectrodes with integrated microchannels for flow through microvoltammetry. 1. The microcell , 2000, Analytical chemistry.

[27]  Samuel P. Kounaves,et al.  Fabrication and Characterization of a Solid State Reference Electrode for Electroanalysis of Natural Waters with Ultramicroelectrodes , 1997 .

[28]  J. Justin Gooding,et al.  Electrochemical DNA Hybridization Biosensors , 2002 .

[29]  Isao Karube,et al.  An integrated three-electrode system with a micromachined liquid-junction Ag/AgCl reference electrode , 1999 .

[30]  Joseph Wang,et al.  Portable electrochemical systems , 2002 .

[31]  W. Cascio,et al.  Electrodeposited iridium oxide pH electrode for measurement of extracellular myocardial acidosis during acute ischemia. , 1998, Analytical chemistry.

[32]  I Karube,et al.  Integration of microfabricated needle-type glucose sensor devices with a novel thin-film Ag/AgCl electrode and plasma-polymerized thin film: mass production techniques. , 2001, The Analyst.

[33]  V. Plichon,et al.  Anodic electrodeposition of iridium oxide films , 1998 .

[34]  S. Marzouk,et al.  Improved electrodeposited iridium oxide pH sensor fabricated on etched titanium substrates. , 2003, Analytical chemistry.

[35]  I. Lauks MICROFABRICATED BIOSENSORS AND MICROANALYTICAL SYSTEMS FOR BLOOD ANALYSIS , 1998 .