Automated processing for proton spectroscopic imaging using water reference deconvolution

Automated formation of MR spectroscopic images (MRSI) is necessary before routine application of these methods is possible for in vivo studies; however, this task is complicated by the presence of spatially dependent instrumental distortions and the complex nature of the MR spectrum. A data processing method is presented for completely automated formation of in vivo proton spectroscopic images, and applied for analysis of human brain metabolites. This procedure uses the water reference deconvolution method (G. A. Morris, J. Magn. Reson. 80,547(1988)) to correct for line shape distortions caused by instrumental and sample characteristics, followed by parametric spectral analysis. Results for automated image formation were found to compare favorably with operator dependent spectral integration methods. While the water reference deconvolution processing was found to provide good correction of spatially dependent resonance frequency shifts, it was found to be susceptible to errors for correction of line shape distortions. These occur due to differences between the water reference and the metabolite distributions.

[1]  G B Matson,et al.  3D phase encoding 1H spectroscopic imaging of human brain. , 1992, Magnetic resonance imaging.

[2]  Matthew O'Donnell,et al.  Correction of phase effects produced by eddy currents in solvent suppressed 1H‐CSI , 1993, Magnetic resonance in medicine.

[3]  George C. Levy,et al.  Spectral deconvolution by simulated annealing , 1989 .

[4]  M. Weiner,et al.  Elevated Lactate and Alkalosis in Chronic Human Brain Infarction Observed by 1H and 31P MR Spectroscopic Imaging , 1992, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[5]  S K Hilal,et al.  Field inhomogeneity correction and data processing for spectroscopic imaging , 1985, Magnetic resonance in medicine.

[6]  G. Fein,et al.  Biochemical alterations in multiple sclerosis lesions and normal‐appearing white matter detected by in vivo 31P and 1H spectroscopic imaging , 1994, Annals of neurology.

[7]  Truman R. Brown,et al.  A method for automatic quantification of one-dimensional spectra with low signal-to-noise ratio , 1987 .

[8]  Gareth A. Morris,et al.  Reference deconvolution. Elimination of distortions arising from reference line truncation , 1991 .

[9]  J. Lindon,et al.  Digitisation and data processing in Fourier transform NMR , 1980 .

[10]  Gareth A. Morris,et al.  Compensation of instrumental imperfections by deconvolution using an internal reference signal , 1988 .

[11]  P Boesiger,et al.  Toward fully automatic estimation of in Vivo 31P spectra , 1991, Magnetic resonance in medicine.

[12]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[13]  D van Ormondt,et al.  Determination of concentrations by time domain fitting of proton nmr echo signals using prior knowledge , 1992, Magnetic resonance in medicine.

[14]  Roger J. Ordidge,et al.  THE CORRECTION OF TRANSIENT B0 FIELD SHIFTS FOLLOWING THE APPLICATION OF PULSED GRADIENTS BY PHASE CORRECTION IN THE TIME DOMAIN , 1986 .

[15]  G. Fein,et al.  Reduced brain N‐acetylaspartate suggests neuronal loss in cognitively impaired human immunodeficiency virus‐seropositive individuals , 1993, Neurology.

[16]  W. Perman,et al.  Spatially resolved high resolution spectroscopy by “four-dimensional” NMR , 1983 .

[17]  Truman R. Brown,et al.  The accuracy of quantification from 1D NMR spectra using the PIQABLE algorithm , 1989 .

[18]  P. Luyten,et al.  Accurate quantification of in vivo 31P NMR signals using the variable projection method and prior knowledge , 1988, Magnetic resonance in medicine.

[19]  A. D. de Graaf,et al.  Quality: quantification improvement by converting lineshapes to the lorentzian type , 1990, Magnetic resonance in medicine.

[20]  K. Uğurbil,et al.  NMR chemical shift imaging in three dimensions. , 1982, Proceedings of the National Academy of Sciences of the United States of America.

[21]  S. Deming,et al.  An automated iterative algorithm for the quantitative analysis of in vivo spectra based on the simplex optimization method , 1989, Magnetic resonance in medicine.

[22]  M W Weiner,et al.  Spectroscopic imaging display and analysis. , 1992, Magnetic resonance imaging.