Volume registration using needle paths and point landmarks for evaluation of interventional MRI treatments

We created a method for three-dimensional (3-D) registration of medical images (e.g., magnetic resonance imaging (MRI) or computed tomography) to images of physical tissue sections or to other medical images and evaluated its accuracy. Our method proved valuable for evaluation of animal model experiments on interventional-MRI guided thermal ablation and on a new localized drug delivery system. The method computes an optimum set of rigid body registration parameters by minimization of the Euclidean distances between automatically chosen correspondence points, along manually selected fiducial needle paths, and optional point landmarks, using the iterative closest point algorithm. For numerically simulated experiments, using two needle paths over a range of needle orientations, mean voxel displacement errors depended mostly on needle localization error when the angle between needles was at least 20/spl deg/. For parameters typical of our in vivo experiments, the mean voxel displacement error was <0.35 mm. In addition, we determined that the distance objective function was a useful diagnostic for predicting registration quality. To evaluate the registration quality of physical specimens, we computed the misregistration for a needle not considered during the optimization procedure. We registered an ex vivo sheep brain MR volume with another MR volume and tissue section photographs, using various combinations of needle and point landmarks. Mean registration error was always /spl les/0.54 mm for MR-to-MR registrations and /spl les/0.52 mm for MR to tissue section registrations. We also applied the method to correlate MR volumes of radio-frequency induced thermal ablation lesions with actual tissue destruction. In this case, in vivo rabbit thigh volumes were registered to photographs of ex vivo tissue sections using two needle paths. Mean registration errors were between 0.7 and 1.36 mm over all rabbits, the largest error less than two MR voxel widths. We conclude that our method provides sufficient spatial correspondence to facilitate comparison of 3-D image data with data from gross pathology tissue sections and histology.

[1]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[2]  F A Jolesz,et al.  Invited. MRI of laser‐induced interstitial thermal injury in an in vivo animal liver model with histologic correlation , 1998, Journal of magnetic resonance imaging : JMRI.

[3]  René M. Botnar,et al.  Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment. Preliminary ex vivo and in vivo results. , 1997, Investigative radiology.

[4]  David L Wilson,et al.  Three‐dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response , 2003, Journal of magnetic resonance imaging : JMRI.

[5]  J. Lewin,et al.  Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. , 1996, AJR. American journal of roentgenology.

[6]  P. Röschmann,et al.  Susceptibility artefacts in NMR imaging. , 1985, Magnetic resonance imaging.

[7]  R. Kikinis,et al.  Integration of interventional MRI with computer‐assisted surgery , 2001, Journal of magnetic resonance imaging : JMRI.

[8]  Roee S. Lazebnik,et al.  X-ray computed tomography methods for in vivo evaluation of local drug release systems , 2002, IEEE Transactions on Medical Imaging.

[9]  J S Lewin,et al.  Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system. , 1998, AJR. American journal of roentgenology.

[10]  J S Lewin,et al.  Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging. , 1997, Investigative radiology.

[11]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[12]  Charles R. Meyer,et al.  Simultaneous usage of homologous points, lines, and planes for optimal, 3-D, linear registration of multimodality imaging data , 1995, IEEE Trans. Medical Imaging.

[13]  J. Lewin,et al.  MRI‐guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: Demonstration of feasibility at 0.2 T , 1999, Magnetic resonance in medicine.

[14]  Charles R. Meyer,et al.  Retrospective correction of intensity inhomogeneities in MRI , 1995, IEEE Trans. Medical Imaging.

[15]  J. Lewin,et al.  MR monitoring of MR‐guided radiofrequency thermal ablation of normal liver in an animal model , 1998, Journal of magnetic resonance imaging : JMRI.

[16]  W. Hall,et al.  Biopsy needle tip artifact in MR‐guided neurosurgery , 2001, Journal of magnetic resonance imaging : JMRI.

[17]  P Boesiger,et al.  Biopsy needle susceptibility artifacts , 1996, Magnetic resonance in medicine.