Volume registration using needle paths and point landmarks for evaluation of interventional MRI treatments
暂无分享,去创建一个
Roee S. Lazebnik | Michael S. Breen | Jonathan S. Lewin | David L. Wilson | Tanya L. Lancaster | J. Lewin | M. Breen | T. L. Lancaster | R. Lazebnik | D. Wilson
[1] Max A. Viergever,et al. A survey of medical image registration , 1998, Medical Image Anal..
[2] F A Jolesz,et al. Invited. MRI of laser‐induced interstitial thermal injury in an in vivo animal liver model with histologic correlation , 1998, Journal of magnetic resonance imaging : JMRI.
[3] René M. Botnar,et al. Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment. Preliminary ex vivo and in vivo results. , 1997, Investigative radiology.
[4] David L Wilson,et al. Three‐dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response , 2003, Journal of magnetic resonance imaging : JMRI.
[5] J. Lewin,et al. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. , 1996, AJR. American journal of roentgenology.
[6] P. Röschmann,et al. Susceptibility artefacts in NMR imaging. , 1985, Magnetic resonance imaging.
[7] R. Kikinis,et al. Integration of interventional MRI with computer‐assisted surgery , 2001, Journal of magnetic resonance imaging : JMRI.
[8] Roee S. Lazebnik,et al. X-ray computed tomography methods for in vivo evaluation of local drug release systems , 2002, IEEE Transactions on Medical Imaging.
[9] J S Lewin,et al. Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system. , 1998, AJR. American journal of roentgenology.
[10] J S Lewin,et al. Generation and observation of radio frequency thermal lesion ablation for interventional magnetic resonance imaging. , 1997, Investigative radiology.
[11] Paul J. Besl,et al. A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..
[12] Charles R. Meyer,et al. Simultaneous usage of homologous points, lines, and planes for optimal, 3-D, linear registration of multimodality imaging data , 1995, IEEE Trans. Medical Imaging.
[13] J. Lewin,et al. MRI‐guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: Demonstration of feasibility at 0.2 T , 1999, Magnetic resonance in medicine.
[14] Charles R. Meyer,et al. Retrospective correction of intensity inhomogeneities in MRI , 1995, IEEE Trans. Medical Imaging.
[15] J. Lewin,et al. MR monitoring of MR‐guided radiofrequency thermal ablation of normal liver in an animal model , 1998, Journal of magnetic resonance imaging : JMRI.
[16] W. Hall,et al. Biopsy needle tip artifact in MR‐guided neurosurgery , 2001, Journal of magnetic resonance imaging : JMRI.
[17] P Boesiger,et al. Biopsy needle susceptibility artifacts , 1996, Magnetic resonance in medicine.