Analysis and compensation of eddy currents in balanced SSFP

Balanced steady‐state free precession (SSFP) completely compensates for all gradients within each repetition time (TR), and is thus very sensitive to any magnetic field imperfection that disturbs the perfectly balanced acquisition scheme. It is demonstrated that balanced SSFP is especially sensitive to changing eddy currents that are induced by stepwise changing phase‐encoding (PE) gradients. In contrast to the linear k‐space trajectory, which has small variations between consecutive encoding steps, other encoding schemes (e.g., centric, random, or segmented orderings) exhibit significant jumps in k‐space between adjacent PE steps, and consequently induce rapidly changing eddy currents. The resulting disturbances induce significant image artifacts, such that compensation strategies are essential when nonlinear PE schemes are applied. Although direct annihilation of the induced eddy currents by additional, opposing magnetic fields has been investigated, it is limited by uncertainty regarding the time evolution of induced eddy currents. A generic (and thus system‐unrelated) compensation strategy is proposed that consists of “pairing” of consecutive PE steps. Another approach is based on partial dephasing along the slice direction that annihilates eddy‐current‐induced signal oscillations. Both pairing of the PE steps and “through‐slice equilibration” are easy to implement and allow the use of arbitrary k‐space trajectories for balanced SSFP. Magn Reson Med 54:129–137, 2005. © 2005 Wiley‐Liss, Inc.

[1]  S. Patz,et al.  Rapid Fourier imaging using steady‐state free precession , 1987, Magnetic resonance in medicine.

[2]  M. L. Wood,et al.  Motion‐insensitive, steady‐state free precession imaging , 1990, Magnetic resonance in medicine.

[3]  M. L. Wood,et al.  Spoiling of transverse magnetization in steady‐state sequences , 1991, Magnetic resonance in medicine.

[4]  W T Sobol,et al.  On the stationary states in gradient echo imaging , 1996, Journal of magnetic resonance imaging : JMRI.

[5]  A. Caprihan,et al.  A programmable pre‐emphasis system , 1998, Magnetic resonance in medicine.

[6]  K. Scheffler,et al.  Single‐breathhold 3D‐trueFISP cine cardiac imaging , 2002, Magnetic resonance in medicine.

[7]  K. Scheffler,et al.  Is TrueFISP a gradient‐echo or a spin‐echo sequence? , 2003, Magnetic resonance in medicine.

[8]  Peter Boesiger,et al.  Accelerating cardiac cine 3D imaging using k‐t BLAST , 2004, Magnetic resonance in medicine.

[9]  Pascal Spincemaille,et al.  View ordering for magnetization prepared steady state free precession acquisition: Application in contrast‐enhanced MR angiography , 2004, Magnetic resonance in medicine.