Compliant four degree-of-freedom manipulator with locally deformable elastic elements for minimally invasive surgery

Minimally Invasive Surgery (MIS) is one of the most successful applications of surgical robots. Although the introduction of robotic technology has brought a number of benefits, further advancements in MIS are limited by the size and bending radius of instruments. In this paper, we present a compliant four degree-of-freedom manipulator that consists of elastic elements with partly thinner structures. The proposed mechanism allows the elastic element to deform locally, thus minimizing its bending radius while the low number of mechanical parts greatly contributes to its compactness. This paper describes the design strategy, optimization method using FEA, prototype implementation, and evaluations. The evaluations reveal high accuracy and repeat accuracy, which are key elements for robotic instruments in MIS. Further, the prototype is able to exert sufficient force and it is possible to perform a simulated needle insertion task using the manipulator, demonstrating the feasibility of the proposed mechanism.

[1]  Peter Kazanzides,et al.  Design and Integration of a Telerobotic System for Minimally Invasive Surgery of the Throat , 2009, Int. J. Robotics Res..

[2]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[3]  Jumpei Arata,et al.  Outer shell type 2 DOF bending manipulator using spring-link mechanism for medical applications , 2010, 2010 IEEE International Conference on Robotics and Automation.

[4]  Robert J. Webster,et al.  Mechanics of Precurved-Tube Continuum Robots , 2009, IEEE Transactions on Robotics.

[5]  C Freschi,et al.  Technical review of the da Vinci surgical telemanipulator , 2013, The international journal of medical robotics + computer assisted surgery : MRCAS.

[6]  H. Jho,et al.  Endoscopic transsphenoidal surgery , 2001, Journal of Neuro-Oncology.

[7]  Russell H. Taylor,et al.  Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..

[8]  Jim Euchner Design , 2014, Catalysis from A to Z.

[9]  G. Dogangil,et al.  A review of medical robotics for minimally invasive soft tissue surgery , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  R. Carrau,et al.  Endoscopic endonasal transsphenoidal surgery: experience with 50 patients. , 1996, Journal of neurosurgery.

[11]  Russell H. Taylor,et al.  A dexterous system for laryngeal surgery , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[12]  J. M. Kaul,et al.  Study of Sphenoid Sinus Anatomy in Relation to Endoscopic Surgery , 2019 .

[13]  D. Rus,et al.  Design, fabrication and control of soft robots , 2015, Nature.

[14]  Mariangela Manti,et al.  Stiffening in Soft Robotics: A Review of the State of the Art , 2016, IEEE Robotics & Automation Magazine.

[15]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[16]  Robert J. Webster,et al.  Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review , 2010, Int. J. Robotics Res..