Detection of Chlamydia trachomatis andNeisseria gonorrhoeae by Enzyme Immunoassay, Culture, and Three Nucleic Acid Amplification Tests

ABSTRACT The purpose of this study was to evaluate and compare three commercially available nucleic acid amplification tests (NAATs) for the detection of Neisseria gonorrhoeae and Chlamydia trachomatis. Roche PCR and Becton Dickinson strand displacement amplification (SDA) were performed on 733 endocervical swab specimens from commercial sex workers. Abbott ligase chain reaction (LCR) was performed on a subset of 396 samples. Endocervical specimens from all women were also tested by culture for N. gonorrhoeae and by Syva MicroTrak enzyme immunoassay (EIA) for C. trachomatis. A positive N. gonorrhoeae result was defined as a positive result by culture or by two NAATs, and a positive C. trachomatis result was defined as a positive result by two tests. According to these definitions, the sensitivities and specificities for the subsample of 396 specimens of N. gonorrhoeae culture, PCR, SDA, and LCR were 69.8, 95.2, 88.9, and 88.9% and 100, 99.4, 100, and 99.1%, respectively; the sensitivities and specificities ofC. trachomatis EIA, PCR, SDA, and LCR were 42.0, 98.0, 94.0, and 90.0% and 100, 98.0, 100, and 98.6%, respectively. The performance characteristics of N. gonorrhoeae culture, PCR, and SDA and C. trachomatis EIA, PCR, and SDA for all 733 specimens were defined without inclusion of LCR results and by discrepant analysis after resolution of discordant N. gonorrhoeae PCR results and of discordant C. trachomatis EIA and PCR results by LCR testing. The sensitivities of N. gonorrhoeae culture, PCR, and SDA before and after LCR resolution were 67.8, 95.7, and 93.9% and 65, 95.8, and 90.0%, respectively. The sensitivities of C. trachomatis EIA, PCR, and SDA decreased from 39.4, 100, and 100% to 38.7, 98.7, and 94.7%, respectively. All three NAATs proved to be superior to N. gonorrhoeae culture and to C. trachomatis EIA. The accuracies of the different NAATs were quite similar. SDA was the only amplification assay with 100% specificity for detection of bothN. gonorrhoeae and C. trachomatis in endocervical specimens.

[1]  W. Miller Can we do better than discrepant analysis for new diagnostic test evaluation? , 1998, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[2]  G. Ridgway,et al.  Comparison of the ligase chain reaction with cell culture for the diagnosis of Chlamydia trachomatis infection in women. , 1996, Journal of clinical pathology.

[3]  K. Carroll,et al.  Evaluation of the Abbott LCx Ligase Chain Reaction Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Urine and Genital Swab Specimens from a Sexually Transmitted Disease Clinic Population , 1998, Journal of Clinical Microbiology.

[4]  J. Schachter Editorial Response: Two Different Worlds We Live In , 1998 .

[5]  M. Loeffelholz,et al.  Detection of Chlamydia trachomatis in endocervical specimens by polymerase chain reaction , 1992, Journal of clinical microbiology.

[6]  T. Quinn,et al.  Direct detection of Chlamydia trachomatis in urine specimens from symptomatic and asymptomatic men by using a rapid polymerase chain reaction assay , 1993, Journal of clinical microbiology.

[7]  J. Wylie,et al.  Comparative Evaluation of Chlamydiazyme, PACE 2, and AMP-CT Assays for Detection of Chlamydia trachomatis in Endocervical Specimens , 1998, Journal of Clinical Microbiology.

[8]  J. Ólafsson,et al.  Comparison of Roche Cobas Amplicor and Abbott LCx for the Rapid Detection of Chlamydia trachomatis in Specimens From High‐Risk Patients , 1998, Sexually transmitted diseases.

[9]  K. Ramotar,et al.  Inhibition of PCR in Genital and Urine Specimens Submitted for Chlamydia trachomatis Testing , 1998, Journal of Clinical Microbiology.

[10]  Helen H. Lee,et al.  Copyright � 1995, American Society for Microbiology Ligase Chain Reaction for Detection of Neisseria gonorrhoeae , 1995 .

[11]  D. Low,et al.  Use of the polymerase chain reaction for the detection of Chlamydia trachomatis from endocervical and urine specimens in an asymptomatic low-prevalence population of women. , 1994, Diagnostic microbiology and infectious disease.

[12]  J. Schachter Two different worlds we live in. , 1998, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[13]  David Baorto,et al.  Reproducibility Problems with the Abbott Laboratories LCx Assay for Chlamydia trachomatis andNeisseria gonorrhoeae , 2000, Journal of Clinical Microbiology.

[14]  H. Verbrugh,et al.  Detection of PCR inhibitors in cervical specimens by using the AMPLICOR Chlamydia trachomatis assay , 1996, Journal of clinical microbiology.

[15]  D. Farrell Evaluation of AMPLICOR Neisseria gonorrhoeae PCR Using cppB Nested PCR and 16S rRNA PCR , 1999, Journal of Clinical Microbiology.

[16]  M S Pepe,et al.  Using a combination of reference tests to assess the accuracy of a new diagnostic test. , 1999, Statistics in medicine.

[17]  R. Waddell,et al.  Detection of Chlamydia trachomatis in urine samples by nucleic acid tests: comparison with culture and enzyme immunoassay of genital swab specimens , 1997, Journal of clinical microbiology.

[18]  M. Lehtinen,et al.  Comparison of Performances of Two Commercially Available Tests, a PCR Assay and a Ligase Chain Reaction Test, in Detection of Urogenital Chlamydia trachomatis Infection , 1998, Journal of Clinical Microbiology.

[19]  A. Hadgu The discrepancy in discrepant analysis , 1996, The Lancet.

[20]  E. Peterson,et al.  Reproducibility problems with the AMPLICOR PCR Chlamydia trachomatis test , 1997, Journal of clinical microbiology.

[21]  S. Kehl,et al.  Evaluation of the Abbott LCx Assay for Detection of Neisseria gonorrhoeae in Endocervical Swab Specimens from Females , 1998, Journal of Clinical Microbiology.

[22]  W. Miller,et al.  Bias in discrepant analysis: when two wrongs don't make a right. , 1998, Journal of clinical epidemiology.

[23]  Helen H. Lee,et al.  Comparison of ligase chain reaction and culture for detection of Neisseria gonorrhoeae in genital and extragenital specimens , 1997, Journal of clinical microbiology.

[24]  Helen H. Lee,et al.  Diagnosis of Chlamydia trachomatis urethral infection in symptomatic and asymptomatic men by testing first-void urine in a ligase chain reaction assay. , 1994, The Journal of infectious diseases.

[25]  Helen H. Lee,et al.  Diagnosis of Neisseria gonorrhoeae infections in women by using the ligase chain reaction on patient-obtained vaginal swabs , 1997, Journal of clinical microbiology.

[26]  H. Young,et al.  PCR testing of genital and urine specimens compared with culture for the diagnosis of chlamydial infection in men and women , 1998, International journal of STD & AIDS.

[27]  A. McAdam,et al.  Discrepant Analysis: How Can We Test a Test? , 2000, Journal of Clinical Microbiology.

[28]  H. Lipman,et al.  Quantifying the bias associated with use of discrepant analysis. , 1998, Clinical chemistry.

[29]  T. Quinn,et al.  Multicenter Evaluation of the AMPLICOR and Automated COBAS AMPLICOR CT/NG Tests for Detection ofChlamydia trachomatis , 2000, Journal of Clinical Microbiology.

[30]  J. Kellogg,et al.  Improved PCR detection of Chlamydia trachomatis by using an altered method of specimen transport and high-quality endocervical specimens , 1995, Journal of clinical microbiology.

[31]  G. V. van Doornum,et al.  Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by ligase chain reaction-based assays with clinical specimens from various sites: implications for diagnostic testing and screening , 1996, Journal of clinical microbiology.

[32]  C. Black,et al.  Evaluation of Bias in Diagnostic-Test Sensitivity and Specificity Estimates Computed by Discrepant Analysis , 1998, Journal of Clinical Microbiology.

[33]  A. Miettinen,et al.  Comparison of manual Amplicor PCR, Cobas Amplicor PCR, and LCx assays for detection of Chlamydia trachomatis infection in women by using urine specimens , 1997, Journal of clinical microbiology.

[34]  T. Quinn,et al.  Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in genitourinary specimens from men and women by a coamplification PCR assay , 1997, Journal of clinical microbiology.