Energy and exergy analysis of intercooled combustion-turbine based combined cycle power plant

An inter-cooled combustion-turbine based combined cycle has been shown to deliver enhanced performance as compared to a simple cycle combustion-turbine based combined cycle. The cycle efficiency of ICCT-CC cycle has been maximized by the selection of an appropriate inter-cooling pressure ratio. The maximum cycle efficiency occurs at lower value of intercooling pressure ratio while the maximum plant work output occurs at higher value of intercooling pressure ratio. The maximum value of plant performance (in terms of efficiency as well as work output) has been observed at inter-cooling pressure ratio of four at overall compressor pressure ratio of 36. An enhancement of 20% in plant work output in case of inter-cooled combustion-turbine based combined cycle in comparison to basic combustion-turbine based combined cycle has been observed, while the plant efficiency is marginally enhanced. Exergy analysis shows that the rational-efficiency of the combustion-turbine is higher by about 3.13% as compared to basic combustion-turbine cycle. Exergy destroyed in components of inter-cooled cycle is lower for all the components except the combustion chamber. Improved plant performance in terms of plant efficiency results in correspondingly reduced green-house-gas emissions.

[1]  Sanjay,et al.  Comparative performance analysis of cogeneration gas turbine cycle for different blade cooling means , 2009 .

[2]  J. H. Horlock,et al.  Limitations on Gas Turbine Performance Imposed by Large Turbine Cooling Flows , 2000 .

[3]  J. F. Louis,et al.  A Comparative Study of the Influence of Different Means of Turbine Cooling on Gas Turbine Performance , 1983 .

[4]  Antonio Peretto,et al.  Thermo-Economic Analysis of an Intercooled, Reheat and Recuperated Gas Turbine for Cogeneration Applications–Part I: Base Load Operation , 2002 .

[5]  Lingen Chen,et al.  Power optimization of an endoreversible closed intercooled regenerated Brayton-cycle coupled to variable-temperature heat-reservoirs , 2005 .

[6]  Tomas Grönstedt,et al.  Design and Analysis of an Intercooled Turbofan Engine , 2010 .

[7]  Gosse Stephane,et al.  UO 2 と炭素間の高温相互作用:超高温原子炉のTRISO粒子への応用 , 2010 .

[8]  Hongguang Jin,et al.  A chemically intercooled gas turbine cycle for recovery of low-temperature thermal energy , 2006 .

[9]  Antonio Peretto,et al.  A Unique Approach for Thermoeconomic Optimization of an Intercooled, Reheat, and Recuperated Gas Turbine for Cogeneration Applications , 2002 .

[11]  Antonio Peretto,et al.  A feasibility study of existing gas turbines for recuperated, intercooled, and reheat cycle , 2004 .

[12]  Sanjay,et al.  Influence of different means of turbine blade cooling on the thermodynamic performance of combined cycle , 2008 .

[13]  Erik Dick,et al.  RAISING CYCLE EFFICIENCY BY INTERCOOLING IN AIR-COOLED GAS TURBINES , 2006 .

[14]  Khaliq Abdul,et al.  熱,冷熱および電力複合生産のためのガスタービン・トリジェネレーションシステムの熱力学的性能評価 , 2008 .

[15]  Lingen Chen,et al.  Power optimization of an irreversible closed intercooled regenerated brayton cycle coupled to variable-temperature heat reservoirs , 2005 .

[16]  Alessandro Franco,et al.  On some perspectives for increasing the efficiency of combined cycle power plants , 2002 .

[17]  Onkar Singh,et al.  Energy and exergy analysis of steam cooled reheat gas–steam combined cycle , 2007 .

[18]  Hui Hong,et al.  An integrated solar thermal power system using intercooled gas turbine and Kalina cycle , 2012 .

[19]  M. A. El-Masri,et al.  GASCAN ― an interactive code for thermal analysis of gas turbine systems , 1988 .

[20]  Ashok Rao,et al.  An evaluation of advanced combined cycles , 2013 .

[21]  Wen-Jei Yang Reduction of specific fuel consumption in gas turbine power plants , 1997 .

[22]  Sanjay Investigation of effect of variation of cycle parameters on thermodynamic performance of gas-steam c , 2010 .

[23]  Christopher J. Koroneos,et al.  Optimum gas turbine cycle for combined cycle power plant , 2008 .

[24]  Antonio Peretto,et al.  A Parametric Thermodynamic Evaluation of High Performance Gas Turbine Based Power Cycles , 2010 .

[25]  Sanjay Exergy and Energy Analysis of Combined Cycle systems with Different Bottoming Cycle Configurations , 2013 .

[26]  M. A. El-Masri Exergy Analysis of Combined Cycles: Part 1—Air-Cooled Brayton-Cycle Gas Turbines , 1987 .

[27]  Sanjay,et al.  Thermodynamic modelling and simulation of advanced combined cycle for performance enhancement , 2008 .

[28]  S. C. Kaushik,et al.  Thermodynamic analysis and parametric study of an irreversible regenerative-intercooled-reheat Brayton cycle , 2006 .

[29]  Wen Xueyou,et al.  Feasibility Study of an Intercooled-Cycle Marine Gas Turbine , 2008 .

[30]  Mats Westermark,et al.  A Study of Humidified Gas Turbines for Short-Term Realization in Midsized Power Generation—Part II: Intercooled Cycle Analysis and Final Economic Evaluation , 2005 .

[31]  Sun Feng-rui,et al.  Power Density Optimization of an Endoreversible Closed Intercooled Regenerated Brayton Cycle Coupled to Variable-temperature Heat Reservoirs , 2005 .