Long-shunt and short-shunt connections on dynamic performance of a SEIG feeding an induction motor load

This paper presents a comparative study of long-shunt and short-shunt configurations on dynamic performance of an isolated self-excited induction generator (SEIG) feeding an induction motor (IM) load. The studied IM is suddenly connected to the output terminals of the studied configurations of the SEIG. Both simulated results and experimental results based on laboratory 1.1 kW induction machines are clearly compared to examine the effects of both connections on voltage variation of the studied SEIG. The analyzed results show that the long-shunt configuration may lead to unwanted oscillations while the short-shunt connection provides better voltage variation. The eigenvalue technique is also employed to examine the possible voltage collapse and unstable conditions in the studied SEIG-IM system.

[1]  T.F. Chan,et al.  Steady-state analysis of self-excited induction generators , 1994, IEEE Power Engineering Review.

[2]  O. P. Malik,et al.  Wind Energy Conversion Using A Self-Excited Induction Generator , 1983, IEEE Transactions on Power Apparatus and Systems.

[3]  Bhim Singh,et al.  Performance characteristics and optimum utilization of a cage machine as capacitance excited induction generator , 1990 .

[4]  Bhim Singh,et al.  Voltage regulator for an isolated self-excited cage induction generator , 1992 .

[5]  T. F. Chan,et al.  Analysis of self-excited induction generators using an iterative method , 1995 .

[6]  B. Singh,et al.  Studies on the use of conventional induction motors as self-excited induction generators , 1988 .

[7]  O. P. Malik,et al.  Analysis of self-excited induction generators , 1982 .

[8]  F. M. Porter,et al.  Capacitive excitation for induction generators , 1935, Electrical Engineering.

[9]  J. Arrillaga,et al.  Controllable d.c. power supply from wind-driven self-excited induction machines , 1979 .

[10]  B. P. Singh,et al.  Analysis of self excited induction generator feeding induction motor , 1994 .

[11]  R. Bonert,et al.  Stand alone induction generator with terminal impedance controller and no turbine controls , 1990 .

[12]  Li Wang,et al.  Dynamic analyses of parallel operated self-excited induction generators feeding an induction motor load , 1999 .

[13]  Li Wang,et al.  Effects of long-shunt and short-shunt connections on voltage variations of a self-excited induction generator , 1997 .

[14]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[15]  Bhim Singh,et al.  Transient performance of the self regulated short shunt self excited induction generator , 1995 .

[16]  M. B. Brennen,et al.  Static Exciters for Induction Generators , 1977, IEEE Transactions on Industry Applications.

[17]  JAMES PATTON,et al.  Analysis of Utility Protection Problems Associated with Small Wind Turbine Interconnections , 1982, IEEE Transactions on Power Apparatus and Systems.

[18]  Bhim Singh,et al.  Selection of capacitors for the self regulated short shunt self excited induction generator , 1995 .

[19]  Bhim Singh,et al.  A step towards improvements in the characteristics of self excited induction generator , 1993 .