Separation of cancer cells using vortical microfluidic flows.

Label-free separation of viable cancer cells using vortical microfluidic flows has been introduced as a feasible cell collection method in oncological studies. Besides the clinical importance, the physics of particle interactions with the vortex that forms in a wall-confined geometry of a microchannel is a relatively new area of fluid dynamics. In our previous work [Haddadi and Di Carlo, J. Fluid. Mech. 811, 436-467 (2017)], we have introduced distinct aspects of inertial flow of dilute suspensions over cavities in a microchannel such as breakdown of the separatrix and formation of stable limit cycle orbits for finite size polystyrene particles. In this work, we extend our experiments to address the engineering-physics of cancer cell entrapment in microfluidic cavities. We begin by studying the effects of the channel width and device height on the morphology of the vortex, which has not been discussed in our previous work. The stable limit cycle orbits of finite size cancer cells are then presented. We demonstrate effects of the separatrix breakdown and the limit cycle formation on the operation of the cancer cell separation platform. By studying the flow of dilute cell suspensions over the cavities, we further develop the notion of the cavity capacity and the relative rate of cell accumulation as optimization criteria which connect the device geometry with the flow. Finally, we discuss the proper placement of multiple cavities inside a microchannel for improved cell entrapment.

[1]  G. Segré,et al.  Behaviour of macroscopic rigid spheres in Poiseuille flow Part 2. Experimental results and interpretation , 1962, Journal of Fluid Mechanics.

[2]  G. Segré,et al.  Behaviour of macroscopic rigid spheres in Poiseuille flow Part 1. Determination of local concentration by statistical analysis of particle passages through crossed light beams , 1962, Journal of Fluid Mechanics.

[3]  J. Riley,et al.  Equation of motion for a small rigid sphere in a nonuniform flow , 1983 .

[4]  F F Becker,et al.  Separation of human breast cancer cells from blood by differential dielectric affinity. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[5]  G. Whitesides,et al.  Fabrication of microfluidic systems in poly(dimethylsiloxane) , 2000, Electrophoresis.

[6]  Julio M. Ottino,et al.  Transport enhancement mechanisms in open cavities , 2002, Journal of Fluid Mechanics.

[7]  Heike Allgayer,et al.  Molecular Staging of Cancer , 2011, Recent Results in Cancer Research.

[8]  Elisabeth Guazzelli,et al.  Inertial migration of rigid spherical particles in Poiseuille flow , 2004, Journal of Fluid Mechanics.

[9]  Alison Stopeck,et al.  Circulating tumor cells, disease progression, and survival in metastatic breast cancer. , 2004, The New England journal of medicine.

[10]  J. Sturm,et al.  Continuous Particle Separation Through Deterministic Lateral Displacement , 2004, Science.

[11]  M. Caggana,et al.  Development of a rare cell fractionation device: application for cancer detection , 2004, IEEE Transactions on NanoBioscience.

[12]  R. Tompkins,et al.  Continuous inertial focusing, ordering, and separation of particles in microchannels , 2007, Proceedings of the National Academy of Sciences.

[13]  Brigitte Rack,et al.  Detection of Circulating Tumor Cells in Peripheral Blood of Patients with Metastatic Breast Cancer: A Validation Study of the CellSearch System , 2007, Clinical Cancer Research.

[14]  S. Digumarthy,et al.  Isolation of rare circulating tumour cells in cancer patients by microchip technology , 2007, Nature.

[15]  Siyang Zheng,et al.  Membrane microfilter device for selective capture, electrolysis and genomic analysis of human circulating tumor cells. , 2007, Journal of chromatography. A.

[16]  H. Stone,et al.  Particle segregation and dynamics in confined flows. , 2009, Physical review letters.

[17]  J. Clausen,et al.  Simulating deformable particle suspensions using a coupled lattice-Boltzmann and finite-element method , 2009, Journal of Fluid Mechanics.

[18]  Mehmet Toner,et al.  Isolation and Characterization of Circulating Tumor Cells from Patients with Localized and Metastatic Prostate Cancer , 2010, Science Translational Medicine.

[19]  Dino Di Carlo,et al.  High-throughput size-based rare cell enrichment using microscale vortices. , 2011, Biomicrofluidics.

[20]  D. Di Carlo,et al.  Rapid prototyping polymers for microfluidic devices and high pressure injections. , 2011, Lab on a chip.

[21]  A Lenshof,et al.  Emerging Clinical Applications of Microchip-Based Acoustophoresis , 2011, Journal of laboratory automation.

[22]  Han Wei Hou,et al.  Pinched flow coupled shear-modulated inertial microfluidics for high-throughput rare blood cell separation. , 2011, Lab on a chip.

[23]  Andrew J Armstrong,et al.  Angiogenesis , Metastasis , and the Cellular Microenvironment Circulating Tumor Cells from Patients with Advanced Prostate and Breast Cancer Display Both Epithelial and Mesenchymal Markers , 2011 .

[24]  Nicole K Henderson-Maclennan,et al.  Deformability-based cell classification and enrichment using inertial microfluidics. , 2011, Lab on a chip.

[25]  Dino Di Carlo,et al.  Hydrodynamic stretching of single cells for large population mechanical phenotyping , 2012, Proceedings of the National Academy of Sciences.

[26]  Bahram Jalali,et al.  High-throughput single-microparticle imaging flow analyzer , 2012, Proceedings of the National Academy of Sciences.

[27]  Michael D. Graham,et al.  Margination and segregation in confined flows of blood and other multicomponent suspensions , 2012 .

[28]  Dino Di Carlo,et al.  Microfluidic Purification and Concentration of Malignant Pleural Effusions for Improved Molecular and Cytomorphological Diagnostics , 2013, PloS one.

[29]  Baskar Ganapathysubramanian,et al.  Engineering fluid flow using sequenced microstructures , 2013, Nature Communications.

[30]  Sumedh R. Risbud,et al.  Trajectory and distribution of suspended non-Brownian particles moving past a fixed spherical or cylindrical obstacle , 2013, Journal of Fluid Mechanics.

[31]  Rajan P Kulkarni,et al.  Size-selective collection of circulating tumor cells using Vortex technology. , 2014, Lab on a chip.

[32]  Scott L Diamond,et al.  Platelet dynamics in three-dimensional simulation of whole blood. , 2014, Biophysical journal.

[33]  J. Harting,et al.  Interplay of inertia and deformability on rheological properties of a suspension of capsules , 2013, Journal of Fluid Mechanics.

[34]  Eugene J. Lim,et al.  Microfluidic, marker-free isolation of circulating tumor cells from blood samples , 2014, Nature Protocols.

[35]  Rajan P Kulkarni,et al.  High efficiency vortex trapping of circulating tumor cells. , 2015, Biomicrofluidics.

[36]  Marcus Roper,et al.  Inertial migration of a rigid sphere in three-dimensional Poiseuille flow , 2013, Journal of Fluid Mechanics.

[37]  H. Inoue,et al.  Change in number and size of circulating tumor cells with high telomerase activity during treatment of patients with gastric cancer. , 2016, Oncology letters.

[38]  Hamed Haddadi,et al.  Inertial flow of a dilute suspension over cavities in a microchannel , 2016, Journal of Fluid Mechanics.

[39]  Hamed Haddadi,et al.  Lattice-Boltzmann simulation of inertial particle-laden flow around an obstacle , 2016 .

[40]  Dino Di Carlo,et al.  Size-tunable microvortex capture of rare cells. , 2017, Lab on a chip.