Assessment of out-of-field absorbed dose and equivalent dose in proton fields.

PURPOSE In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may increase the risk of radiation-induced secondary cancer and interact with electronic devices in the treatment room. The authors implement a Monte Carlo model of this dose deposited outside passively scattered fields and compare it to measurements, determine the out-of-field equivalent dose, and estimate the change in the dose if the same target volumes were treated with an active beam scanning technique. METHODS Measurements are done with a thimble ionization chamber and the Wellhofer MatriXX detector inside a Lucite phantom with field configurations based on the treatment of prostate cancer and medulloblastoma. The authors use a GEANT4 Monte Carlo simulation, demonstrated to agree well with measurements inside the primary field, to simulate fields delivered in the measurements. The partial contributions to the dose are separated in the simulation by particle type and origin. RESULTS The agreement between experiment and simulation in the out-of-field absorbed dose is within 30% at 10-20 cm from the field edge and 90% of the data agrees within 2 standard deviations. In passive scattering, the neutron contribution to the total dose dominates in the region downstream of the Bragg peak (65%-80% due to internally produced neutrons) and inside the phantom at distances more than 10-15 cm from the field edge. The equivalent doses using 10 for the neutron weighting factor at the entrance to the phantom and at 20 cm from the field edge are 2.2 and 2.6 mSv/Gy for the prostate cancer and cranial medulloblastoma fields, respectively. The equivalent dose at 15-20 cm from the field edge decreases with depth in passive scattering and increases with depth in active scanning. Therefore, active scanning has smaller out-of-field equivalent dose by factors of 30-45 in the entrance region and this factor decreases with depth. CONCLUSIONS The dose deposited immediately downstream of the primary field, in these cases, is dominated by internally produced neutrons; therefore, scattered and scanned fields may have similar risk of second cancer in this region. The authors confirm that there is a reduction in the out-of-field dose in active scanning but the effect decreases with depth. GEANT4 is suitable for simulating the dose deposited outside the primary field. The agreement with measurements is comparable to or better than the agreement reported for other implementations of Monte Carlo models. Depending on the position, the absorbed dose outside the primary field is dominated by contributions from primary protons that may or may not have scattered in the brass collimating devices. This is noteworthy as the quality factor of the low LET protons is well known and the relative dose risk in this region can thus be assessed accurately.

[1]  Brian Wang,et al.  Simulation of organ-specific patient effective dose due to secondary neutrons in proton radiation treatment , 2005, Physics in medicine and biology.

[2]  Anatoly Rosenfeld,et al.  Out-of-field dose equivalents delivered by proton therapy of prostate cancer. , 2007, Medical physics.

[3]  A. Koehler,et al.  Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation field , 2002 .

[4]  Chan Hyeong Kim,et al.  Prompt gamma measurements for locating the dose falloff region in the proton therapy , 2006 .

[5]  Robert J. Schneider,et al.  Range modulators for protons and heavy ions , 1975 .

[6]  E. Benton,et al.  Leakage and scatter radiation from a double scattering based proton beamline. , 2007, Medical physics.

[7]  W. Newhauser,et al.  Equivalent dose and effective dose from stray radiation during passively scattered proton radiotherapy for prostate cancer , 2008, Physics in medicine and biology.

[8]  Harald Paganetti,et al.  Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields , 2006, Physics in medicine and biology.

[9]  W. Newhauser,et al.  Monte Carlo simulations of neutron spectral fluence, radiation weighting factor and ambient dose equivalent for a passively scattered proton therapy unit , 2008, Physics in medicine and biology.

[10]  H. Blattmann Beam delivery systems for charged particles , 1992, Radiation and environmental biophysics.

[11]  Jack Valentin,et al.  Relative biological effectiveness (RBE), quality factor (Q), and radiation weighting factor (wR) , 2003 .

[12]  Matthias Fippel,et al.  A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations , 2005, Physics in medicine and biology.

[13]  E. Hall,et al.  Intensity-modulated radiation therapy, protons, and the risk of second cancers. , 2006, International journal of radiation oncology, biology, physics.

[14]  J. H. Hough,et al.  Secondary Dose Exposures During 200 MeV Proton Therapy , 1997 .

[15]  A M Koehler,et al.  Flattening of proton dose distributions for large-field radiotherapy. , 1977, Medical physics.

[16]  D. Brenner,et al.  Secondary neutrons in clinical proton radiotherapy: a charged issue. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  H Paganetti,et al.  Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility. , 2004, Medical physics.

[18]  G Ciangaru,et al.  Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study , 2009, Physics in medicine and biology.

[19]  H. Paganetti,et al.  Physics Settings for Using the Geant4 Toolkit in Proton Therapy , 2008, IEEE Transactions on Nuclear Science.

[20]  S Agosteo,et al.  Secondary neutron and photon dose in proton therapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  P. Andreo,et al.  Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water , 2001 .

[22]  Anatoly Rosenfeld,et al.  Out-of-field dose equivalents delivered by passively scattered therapeutic proton beams for clinically relevant field configurations. , 2008, International journal of radiation oncology, biology, physics.

[23]  J Flanz,et al.  Overview of the MGH-Northeast Proton Therapy Center plans and progress , 1995 .

[24]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[25]  T. Hashimoto,et al.  Proton beam therapy interference with implanted cardiac pacemakers. , 2008, International journal of radiation oncology, biology, physics.

[26]  R. Stewart,et al.  Neutron scattered dose equivalent to a fetus from proton radiotherapy of the mother. , 2006, Medical physics.

[27]  E Pedroni,et al.  Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams , 2005, Physics in medicine and biology.

[28]  M. Tadokoro,et al.  Measurement of neutron dose distribution for a passive scattering nozzle at the Proton Medical Research Center (PMRC) , 2006 .

[29]  Harald Paganetti,et al.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction , 2008, Physics in medicine and biology.

[30]  W. Newhauser,et al.  Calculations of neutron dose equivalent exposures from range-modulated proton therapy beams , 2005, Physics in medicine and biology.

[31]  T. Sakae,et al.  Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies. , 2008, Medical physics.

[32]  E. Pedroni,et al.  Secondary neutron dose during proton therapy using spot scanning. , 2002, International journal of radiation oncology, biology, physics.

[33]  H Paganetti,et al.  Nuclear interactions in proton therapy: dose and relative biological effect distributions originating from primary and secondary particles. , 2002, Physics in medicine and biology.

[34]  Harald Paganetti,et al.  Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms , 2008, Physics in medicine and biology.

[35]  A. Heimers Cytogenetic analysis in human lymphocytes after exposure to simulated cosmic radiation which reflects the inflight radiation environment. , 1999, International journal of radiation biology.