Prediction of fluid responsiveness for patients in shock using a ventilator disconnection test combined with the pulse contour-derived cardiac index.

BACKGROUND Finding a simple and reliable method to predict and assess fluid responsiveness has long been of clinical interest. OBJECTIVE To investigate the predictive value of a ventilator disconnection (DV) test combined with the pulse contour-derived cardiac output (PiCCO) index on fluid responsiveness for patients in shock. METHODS Thirty-two patients were chosen for the study. Patients who were in shock, received mechanical ventilation, and met the inclusion criteria were selected. Patients were divided into a fluid-responsive group (14 patients) and fluid-unresponsive group (18 patients) based on whether the increase in cardiac index (Δ CI) was > 10% or not, respectively, following the fluid challenge test. Changes in heart rate, pulse oximeter-measured oxygen saturation, mean arterial pressure (MAP), and CI before and after passive leg raising (PLR), DV, and fluid challenge tests were observed. We used Pearson's correlation coefficient to analyze an increase in the MAP (Δ MAP) and Δ CI before and after the PLR, DV, and fluid challenge tests; the sensitivity and specificity of the Δ MAP and Δ CI in the PLR and DV tests for predicting fluid response were also analyzed by plotting the receiver operating characteristic (ROC) curves. RESULTS CI results in the PLR and DV tests, as well as the fluid challenge test, were significantly higher in the fluid-responsive group compared with before the test (P< 0.05). The Δ CI before and after the PLR, DV, and fluid challenge tests were positively correlated among patients in the fluid-responsive group. The area under the ROC curve for the post-PLR test CI and the post-DV CI for predicting fluid responsiveness was 0.869 (95% confidence interval (CI) [0.735-1.000, P= 0.000]) and 0.937 (95% CI [0.829-1.000, P= 0.000]), respectively, in patients in the fluid-responsive group. The sensitivity and specificity of the post-DV CI for predicting fluid responsiveness in all patients was 100.0% and 88.9%, respectively, using a 5% increase as the cut-off value. CONCLUSION Application of DV, combined with PiCCO, has a high predictive value for fluid responsiveness among patients in shock.

[1]  C. Richard,et al.  Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance* , 2012, Critical care medicine.

[2]  Xavier Monnet,et al.  Hemodynamic parameters to guide fluid therapy , 2011, Annals of intensive care.

[3]  M. Cannesson Arterial pressure variation and goal-directed fluid therapy. , 2010, Journal of cardiothoracic and vascular anesthesia.

[4]  F. Saulnier,et al.  Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis* , 2010, Critical care medicine.

[5]  R. Cavallazzi,et al.  Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature* , 2009, Critical care medicine.

[6]  D. Osman,et al.  Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients , 2009, Critical care medicine.

[7]  Michael Baram,et al.  Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. , 2008, Chest.

[8]  J. Teboul,et al.  Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity , 2008, Current opinion in critical care.

[9]  J. Teboul,et al.  Passive leg raising , 2008, Intensive Care Medicine.

[10]  P. Marik,et al.  Noninvasive hemodynamic monitoring in the intensive care unit. , 2007, Critical care clinics.

[11]  P. Ray,et al.  Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge* , 2007, Critical care medicine.

[12]  Y. Amoateng-Adjepong,et al.  Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study. , 2000, Chest.

[13]  A. Rossi,et al.  Intrinsic positive end-expiratory pressure (PEEPi) , 1995, Intensive Care Medicine.

[14]  J. Vincent,et al.  Circulatory shock. , 2013, The New England journal of medicine.

[15]  M. Pinsky,et al.  Passive leg raising predicts fluid responsiveness in the critically ill. , 2006, Critical care medicine.

[16]  J. Teboul,et al.  Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. , 2002, Chest.