Reliability and failure modes of internal conical dental implant connections.

OBJECTIVE Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT). MATERIALS AND METHODS Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed(™) TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda., Campo Largo, PR, Brazil). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Differences between groups were assessed by Kruskal-Wallis along with Bonferroni's post-hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. RESULTS The Beta (β) value derived from use level probability Weibull calculation was 1.62 (1.01-2.58) for group AT and 2.56 (1.76-3.74) for group SV, indicating that fatigue was an accelerating factor for failure of both groups. The reliability for group AT was 0.95 and for group SV was 0.88. Kruskal-Wallis along with Bonferroni's post-hoc tests showed no significant difference between the groups tested (P > 0.27). In all specimens of both groups, the chief failure mode was abutment fracture at the conical joint region and screw fracture at neck's region. CONCLUSIONS Reliability was not different between investigated ICI connections supporting maxillary incisor crowns. Failure modes were similar.

[1]  G A Niznick,et al.  Bending overload and implant fracture: a retrospective clinical analysis. , 1996, The International journal of oral & maxillofacial implants.

[2]  S. Müftü,et al.  Mechanics of the tapered interference fit in dental implants. , 2003, Journal of biomechanics.

[3]  Akihiko Hashimoto,et al.  Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system. , 2004, The Journal of prosthetic dentistry.

[4]  M. Norton,et al.  An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design. , 2000, Clinical oral implants research.

[5]  J. Sloten,et al.  Influence of implant connection type on the biomechanical environment of immediately placed implants - CT-based nonlinear, three-dimensional finite element analysis. , 2009, Clinical implant dentistry and related research.

[6]  Bjarni E Pjetursson,et al.  A systematic review of the survival and complication rates of resin-bonded bridges after an observation period of at least 5 years , 2008, BDJ.

[7]  K. Ludwig,et al.  Implant-abutment interface design affects fatigue and fracture strength of implants. , 2008, Clinical oral implants research.

[8]  P. Psyllaki,et al.  Observations on an in-vivo failure of a titanium dental implant/abutment screw system: a case report. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[9]  P. Coelho,et al.  Reliability and failure modes of anterior single-unit implant-supported restorations. , 2012, Clinical oral implants research.

[10]  E. D. Rekow,et al.  Fatigue testing of two porcelain-zirconia all-ceramic crown systems. , 2009, Dental materials : official publication of the Academy of Dental Materials.

[11]  Ewan Macarthur,et al.  Accelerated Testing: Statistical Models, Test Plans, and Data Analysis , 1990 .

[12]  P. Binon EVALUATION OF THREE SLIP FIT HEXAGONAL IMPLANTS , 1996, Implant dentistry.

[13]  I. Garcia,et al.  Resolution of a titanium implant fracture after a recurrent trauma. , 2010, Dental traumatology : official publication of International Association for Dental Traumatology.

[14]  J W Osborn,et al.  The effect of pressure on a maximum incisal bite force in man. , 1997, Archives of oral biology.

[15]  D Buser,et al.  Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. , 2001, Journal of periodontology.

[16]  E. Elsayed,et al.  A general accelerated life model for step-stress testing , 2005 .

[17]  U. Belser,et al.  Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. , 2000, The International journal of oral & maxillofacial implants.

[18]  W. B. Nelson,et al.  A bibliography of accelerated test plans , 2005, IEEE Transactions on Reliability.

[19]  K Wannfors,et al.  A prospective clinical evaluation of different single-tooth restoration designs on osseointegrated implants. A 3-year follow-up of Brånemark implants. , 1999, Clinical oral implants research.

[20]  D. Cochran,et al.  Initial implant position determines the magnitude of crestal bone remodeling. , 2004, Journal of periodontology.

[21]  Robert B. Abernethy,et al.  The new Weibull handbook , 1993 .

[22]  F. Higginbottom,et al.  Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: results of loading for 2 or more years. , 1999, The International journal of oral & maxillofacial implants.

[23]  John Botsis,et al.  Fatigue resistance of ITI implant-abutment connectors -- a comparison of the standard cone with a novel internally keyed design. , 2002, Clinical oral implants research.

[24]  E. D. Rekow,et al.  Laboratory Simulation of Y-TZP All-ceramic Crown Clinical Failures , 2009, Journal of dental research.

[25]  Ameen Khraisat,et al.  Fatigue resistance of two implant/abutment joint designs. , 2002, The Journal of prosthetic dentistry.

[26]  Wayne Nelson Models and Data Analyses for Step and Varying Stress , 2008 .

[27]  Hiok Chai Quek,et al.  Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system. , 2008, The International journal of oral & maxillofacial implants.

[28]  Ronald J. Parrington,et al.  Fractography of metals and plastics , 2002 .

[29]  J. Hirsch,et al.  Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. , 1998, European journal of oral sciences.

[30]  W. Meeker Accelerated Testing: Statistical Models, Test Plans, and Data Analyses , 1991 .

[31]  D. Cochran,et al.  Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: a radiographic study in the canine mandible. , 2002, Journal of periodontology.

[32]  A. Piattelli,et al.  Prospective evaluation of 2,549 Morse taper connection implants: 1- to 6-year data. , 2011, Journal of periodontology.

[33]  A Piattelli,et al.  Prospective clinical evaluation of 1920 Morse taper connection implants: results after 4 years of functional loading. , 2009, Clinical oral implants research.

[34]  J. Hirsch,et al.  Biological factors contributing , 1998 .

[35]  G. Priest Single-tooth implants and their role in preserving remaining teeth: a 10-year survival study. , 1999, The International journal of oral & maxillofacial implants.

[36]  H. Iplikçioğlu,et al.  Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant: influence of abutment design. , 2004, Clinical oral implants research.

[37]  S. Scholander A retrospective evaluation of 259 single-tooth replacements by the use of Brånemark implants. , 1999, The International journal of prosthodontics.

[38]  W. B. Nelson,et al.  A bibliography of accelerated test plans part II - references , 2005, IEEE Transactions on Reliability.