Accurate and consistent automatic seismocardiogram annotation without concurrent ECG

Seismocardiography (SCG) is the measurement of vibrations in the sternum caused by the beating of the heart. Precise cardiac mechanical timings that can only be obtained from SCG are critically dependent on accurate identification offiducial points. So far, SCG annotation has relied on concurrent ECG measurements. We have designed an algorithm capable of annotating SCG without the use any other concurrent measurement. We subjected 18 participants to graded lower body negative pressure. We collected ECG and SCG, obtained R peaksfrom the former, and annotated the latter by hand, using these identified peaks. We also annotated the SCG automatically. We compared the isovolumic moment timings obtained by hand to those obtained using our algorithm. Mean accuracies for increasing levels of negative pressure were 97.61 ± 3.39%, 93.32 ± 5.33%, 78.28 ± 14.29%, 58.68 ± 17.58%, and 63.36 ±14.23%. We also compared LF/HF ratios obtained from isovolumic moments to those obtained from R peaks. For indices obtainedfrom automatic annotations, the mean differences were 0.16±0.19, -0.10±0.58, 0.89±0.85, -1.22±0.62, and 2.30 ± 1.10 for increasing levels of negative pressure.

[1]  Kouhyar Tavakolian,et al.  Seismocardiograms return valid heart rate variability indices , 2013, Computing in Cardiology 2013.

[2]  Miguel A. García-González,et al.  Heart rate variability analysis using a seismocardiogram signal , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  D. Salerno,et al.  Seismocardiography for monitoring changes in left ventricular function during ischemia. , 1991, Chest.

[4]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[5]  Kouhyar Tavakolian,et al.  Automatic Annotation of Seismocardiogram With High-Frequency Precordial Accelerations , 2015, IEEE Journal of Biomedical and Health Informatics.

[6]  Carlo Menon,et al.  Moving toward automatic and standalone delineation of seismocardiogram signal , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[7]  H. Nazeran,et al.  Comparison of Heart Rate Variability Signal Features Derived from Electrocardiography and Photoplethysmography in Healthy Individuals , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  Peter J. Hannan,et al.  Relationship between seismocardiogram and echocardiogram for events in the cardiac cycle , 1994 .

[9]  W.J. Tompkins,et al.  ECG beat detection using filter banks , 1999, IEEE Transactions on Biomedical Engineering.

[10]  Francesco Rizzo,et al.  A textile-based wearable system for the prolonged assessment of cardiac mechanics in daily life , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Xavier L. Aubert,et al.  Heart rate estimation on a beat-to-beat basis via ballistocardiography - a hybrid approach , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[12]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[13]  L E Lamb,et al.  Effects of lower body negative pressure on the cardiovascular system. , 1965, The American journal of cardiology.

[14]  A. Porta,et al.  Contrasting effects of phentolamine and nitroprusside on neural and cardiovascular variability. , 2001, American journal of physiology. Heart and circulatory physiology.

[15]  Jeffrey C. Lagarias,et al.  Convergence Properties of the Nelder-Mead Simplex Method in Low Dimensions , 1998, SIAM J. Optim..

[16]  Ari Paasio,et al.  Seismocardiography: Toward heart rate variability (HRV) estimation , 2015, 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings.

[17]  D L Eckberg,et al.  Human sinus arrhythmia as an index of vagal cardiac outflow. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[18]  Jae Hyuk Shin,et al.  Heart rate variability analysis using a ballistocardiogram during Valsalva manoeuvre and post exercise , 2011, Physiological measurement.

[19]  J. Saul,et al.  Transfer function analysis of the circulation: unique insights into cardiovascular regulation. , 1991, The American journal of physiology.

[20]  C. Julien The enigma of Mayer waves: Facts and models. , 2006, Cardiovascular research.

[21]  Kathy L Ryan,et al.  Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans. , 2004, Journal of applied physiology.

[22]  Kouhyar Tavakolian,et al.  Seismocardiography: Past, present and future , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[23]  J. M. Zanetti,et al.  Exercise seismocardiography for detection of coronary artery disease , 1992 .

[24]  Bozena Kaminska,et al.  Estimation of hemodynamic parameters from seismocardiogram , 2010, 2010 Computing in Cardiology.

[25]  Hannu Toivonen,et al.  Adaptive Heartbeat Modeling for Beat-to-Beat Heart Rate Measurement in Ballistocardiograms , 2015, IEEE Journal of Biomedical and Health Informatics.

[26]  Kouhyar Tavakolian,et al.  Ballistocardiography and Seismocardiography: A Review of Recent Advances , 2015, IEEE Journal of Biomedical and Health Informatics.

[27]  J. H. Shin,et al.  Automatic ballistocardiogram (BCG) beat detection using a template matching approach , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  Francesco Rizzo,et al.  Wearable Seismocardiography: Towards the beat-to-beat assessment of cardiac mechanics during sleep in microgravity , 2014, 2014 8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO).

[29]  S. Leonhardt,et al.  Unsupervised Heart Rate Variability Estimation from Ballistocardiograms , 2013 .

[30]  Kouhyar Tavakolian,et al.  Precordial Vibrations Provide Noninvasive Detection of Early-Stage Hemorrhage , 2014, Shock.