Successful Removal of Uncoiled J-Tip Guidewire

through the right corner of the mouth (Fig 2). The thin blade of the McGrath also contributed to easy handling of the TEE probe. Repeated attempts to insert the TEE probe against a certain resistance in a blind manner can cause potentially harmful complications. It would be better to get direct visualization of the esophageal orifice. If it is available, the McGrath videolaryngoscope could be a better option for anesthesiologists for TEE probe insertion in anesthetized patients with an ETT in place.

[1]  G. Umesh,et al.  Difficulty in the diagnosis of a retained guidewire within the central venous catheter. , 2013, Journal of cardiothoracic and vascular anesthesia.

[2]  R. Chabanne,et al.  Arterial injury complicating subclavian central venous catheter insertion. , 2012, Journal of cardiothoracic and vascular anesthesia.

[3]  Albert Robinson Caution when positioning central venous catheter and its relationship to the pericardial reflection. , 2007, Journal of cardiothoracic and vascular anesthesia.

[4]  T. Shimamoto,et al.  [Breakage of a Seldinger spring guide wire during percutaneous catheterization of a subclavian vein]. , 1997, Masui. The Japanese journal of anesthesiology.

[5]  Jacob Chacko,et al.  Complications with guide wires for central vein cannulation , 1991, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[6]  G. Finley A complication of external jugular vein catheterization in children , 1988, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[7]  J. C. Shields,et al.  A Guide Wire Uncoiling During a Central Line Exchange , 2011, International anesthesiology clinics.