Whole Blood Volume Determined by Radiochromium‐Tagged Red Cells: Comparative Studies on Normal and Congestive Heart Failure Patients

Whole blood volume can be measured quite accurately by the use of radiochromium. The amount of radiation is very low; the radiochromium stays fixed in red blood cells for many hours and does not leave the circulation as may happen when plasma tags are employed. Hypervolemia was found in the majority of patients with right ventricular failure but not in those with left ventricular failure or mitral stenosis alone.

[1]  R. Ebert,et al.  A critical comparison of the T-1824 dye and iodinated albumin methods for plasma volume measurement. , 1953, The Journal of clinical investigation.

[2]  R. J. Parsons,et al.  Total red cell volume, plasma volume, and sodium space in congestive heart failure. , 1951, The Journal of clinical investigation.

[3]  S. Gray,et al.  The tagging of red cells and plasma proteins with radioactive chromium. , 1950, The Journal of clinical investigation.

[4]  S. Gray,et al.  Determination of the circulating red cell volume in man by radioactive chromium. , 1950, The Journal of clinical investigation.

[5]  K. R. Crispell,et al.  Studies of plasma volume using human serum albumin tagged with radioactive iodine. , 1950, The Journal of clinical investigation.

[6]  R. Elman,et al.  BLOOD VOLUME DETERMINATION IN THE HUMAN WITH RED CELLS CONTAINING RADIOACTIVE PHOSPHORUS (P) AND WITH PURE HUMAN ALBUMIN. , 1948, The Journal of clinical investigation.

[7]  J. P. Peters The role of sodium in the production of edema. , 1948, The New England journal of medicine.

[8]  G. Nylin,et al.  Weight of the red blood corpuscles in heart failure determined with labelled erythrocytes during and after decompensation. , 1947, American heart journal.

[9]  A. Seligman,et al.  CIRCULATING RED CELL VOLUME MEASURED SIMULTANEOUSLY BY THE RADIOACTIVE IRON AND DYE METHODS. , 1946, The Journal of clinical investigation.

[10]  A. Kip,et al.  The measurement of the circulating red cell volume by means of two radioactive isotopes of iron. , 1946, The Journal of clinical investigation.

[11]  G. Nylin BLOOD VOLUME DETERMINATIONS WITH RADIOACTIVE PHOSPHORUS , 1945, British heart journal.

[12]  W. Pritchard,et al.  CARDIAC OUTPUT, BLOOD AND INTERSTITIAL FLUID VOLUMES, TOTAL CIRCULATING SERUM PROTEIN, AND KIDNEY FUNCTION DURING CARDIAC FAILURE AND AFTER IMPROVEMENT. , 1942, The Journal of clinical investigation.

[13]  G. Whipple,et al.  RED CELL AND PLASMA VOLUMES (CIRCULATING AND TOTAL) AS DETERMINED BY RADIO IRON AND BY DYE , 1942, The Journal of experimental medicine.

[14]  E. A. Stead,et al.  DEMONSTRATION THAT THE CELL PLASMA RATIO OF BLOOD CONTAINED IN MINUTE VESSELS IS LOWER THAN THAT OF VENOUS BLOOD. , 1941, The Journal of clinical investigation.

[15]  G. Hevesy,et al.  A Method of Blood Volume Determination , 1940 .

[16]  W. A. Evans,et al.  CLINICAL STUDIES OF THE BLOOD VOLUME. III. CHANGES IN BLOOD VOLUME, VENOUS PRESSURE AND BLOOD VELOCITY RATE IN CHRONIC CONGESTIVE HEART FAILURE. , 1937, The Journal of clinical investigation.

[17]  George E. Brown,et al.  THE VOLUME AND COMPOSITION OF THE BLOOD, AND THE CHANGES INCIDENT TO DIURESIS, IN CASES OF EDEMA , 1925 .