Characterising the d-axis machine model of a turbogenerator using finite elements

An analysis of a long established fundamental assumption is presented. The assumption that superposition is valid in frequency response derived models is shown to be wrong, because eddy current losses in the solid rotor cannot be superimposed in the machine direct-axis. This implies that network theory is not valid in characterising the d-axis machine model. A machine model structure with one damper winding in the d-axis is derived from finite element analysis. Unequal mutual inductances in the machine d-axis are determined and hence the so-called differential leakage inductances are found and they are frequency dependent. The study is made on a 150 MVA turbine generator by simulating the standstill frequency response test with finite elements.

[1]  A. Walton,et al.  Characteristics of equivalent circuits of synchronous machines , 1996 .

[2]  I. Kamwa,et al.  A frequency-domain maximum likelihood estimation of synchronous machine high-order models using SSFR test data , 1992 .

[3]  Philippe Viarouge,et al.  Three-transfer-function approach for building phenomenological models of synchronous machines , 1994 .

[4]  D. C. MacDonald Lumped modelling of open-circuit turbogenerator operational parameters , 1999 .

[5]  R. H. Park,et al.  Two-reaction theory of synchronous machines generalized method of analysis-part I , 1929, Transactions of the American Institute of Electrical Engineers.

[6]  I. M. Canay Physical significance of sub-subtransient quantities in dynamic behaviour of synchronous machines , 1988 .

[7]  Gabriel Kron Equivalent Circuits of Electric Machinery. , 1967 .

[8]  L. G. Meng,et al.  Frequency domain-based methods to predict turbogenerator transients with particular emphasis on the field current , 1989 .

[9]  Ali Keyhani,et al.  Identification of high-order synchronous generator models from SSFR test data , 1994 .

[10]  I. M. Canay,et al.  Modelling of alternating-current machines having multiple rotor circuits , 1993 .

[11]  A. M. El-Serafi,et al.  A 'three transfer functions' approach for the standstill frequency response test of synchronous machines , 1990 .

[12]  G. S. Raju,et al.  MATHEMATICAL MODELS OF SYNCHRONOUS MACHINE WITH UNEQUAL MUTUAL REACTANCES , 1981 .

[13]  Charles Concordia,et al.  Synchronous machines : theory and performance , 1951 .

[14]  M. Savino,et al.  EXACT RELATIONSHIPS BETWEEN PARAMETERS AND TEST DATA FOR MODELS OF SYNCHRONOUS MACHINES , 1983 .

[15]  Marco Antonio,et al.  Steady state and frequency domain lumped model numerical characterisation of solid rotor synchronous generators , 1996 .

[16]  Loyal Vivian Bewley Two-dimensional fields in electrical engineering , 1948 .

[17]  Y. Takeda,et al.  Determination of synchronous-machine parameters allowing for unequal mutual inductances , 1974 .

[18]  I. M. Canay,et al.  Causes of Discrepancies on Calculation of Rotor Quantities and Exact Equivalent Diagrams of the Synchronous Machine , 1969 .

[19]  M. V. Valkenburg Network Analysis , 1964 .

[20]  A L Marco Arjona,et al.  LUMPED MODELLING OF OPEN-CIRCUIT TURBOGENERATOR OPERATIONAL PARAMETERS , 1999 .

[21]  R. H. Park,et al.  Two-reaction theory of synchronous machines-II , 1933, Transactions of the American Institute of Electrical Engineers.

[22]  T. J. Bedford,et al.  A method to compute transients in synchronous generators using frequency domain methods , 1988 .

[23]  Yao-nan Yu,et al.  Experimental Determination of Exact Equivalent Circuit Parameters of Synchronous Machines , 1971 .

[24]  Ronald G. Harley,et al.  The General Theory of Alternating Current Machines , 1975 .

[25]  M. R. Iravani,et al.  Impact of synchronous machine constants and models on the analysis of torsional dynamics , 1992 .