CT-scan images preprocessing and segmentation to improve bioprosthesis leaflets morphological analysis.

The visualization of bioprosthesis leaflet morphology might help to better understand the underlying mechanism of dysfunction in degenerated aortic bioprosthesis. Because today such visualization of bioprosthesis leaflet morphology is intricate to impossible with other imaging techniques, we hypothesized that the processing of multi-detector CT images would allow better visualization of the prosthetic valve leaflets after biological aortic valve replacement. The purpose of our study was to prospectively evaluate patients with a degenerated aortic bioprosthesis, waiting for reoperation, by using 64-slice CT to evaluate prosthetic leaflets morphology. A semi-automatic segmentation of pre-operative tomodensitometric images was conducted, using 2 different implementations of the region growing algorithm. Here we report all segmentation steps (selection of the region of interest, filtering, segmentation). Studied degenerated aortic bioprostheses were represented by two Carpentier-Edwards Supra Annular Valve (porcine leaflets), one Edwards Perimount (pericardial leaflets) and one Medtronic Mosaic (porcine leaflets). Both segmentation methods (Isotropic Region Growing and Stick Region Growing) allowed a semi-automatic segmentation with 3D reconstruction of all bioprosthetic components (stent, leaflets, degeneration/calcifications). Explanted bioprosthesis CT images were also processed and used as reference. Segmentation results were compared by means of quantitative criteria. Semi-automatic segmentation using region growing algorithm seems to provide an interesting approach for the morphological characterization of degenerated aortic bioprostheses. We believe that in the next future CT scan images segmentation may play an important role to better understand the mechanism of dysfunction in failing aortic bioprostheses. Moreover, bioprostheses 3D reconstructions could be integrated into preoperative planning tools to optimize valve-in-valve procedure.

[1]  J.D.F. Habbema,et al.  Prognosis After Aortic Valve Replacement With a Bioprosthesis: Predictions Based on Meta-Analysis and Microsimulation , 2001, Circulation.

[2]  W G Henderson,et al.  A comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis. Veterans Affairs Cooperative Study on Valvular Heart Disease. , 1993, The New England journal of medicine.

[3]  Jörg Hausleiter,et al.  Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial. , 2007, European heart journal.

[4]  T. Callister,et al.  Evaluation of prosthetic valve endocarditis by 64-row multidetector computed tomography. , 2007, International journal of cardiology.

[5]  Gernot Brockmann,et al.  Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2). , 2011, JACC. Cardiovascular interventions.

[6]  Zhonghua Sun,et al.  Diagnostic value of multislice computed tomography angiography in coronary artery disease: a meta-analysis. , 2006, European journal of radiology.

[7]  M. Budoff,et al.  Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Indi , 2008, Journal of the American College of Cardiology.

[8]  William Wijns,et al.  Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis. , 2007, Radiology.

[9]  T. Boskamp,et al.  New vessel analysis tool for morphometric quantification and visualization of vessels in CT and MR imaging data sets. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[10]  S. Aoyagi,et al.  Prosthetic valve obstruction: diagnostic usefulness of cineradiography and multidetector-row computed tomography. , 2007, The Thoracic and cardiovascular surgeon.

[11]  A. Leguerrier,et al.  Long-term results of the carpentier-edwards supraannular aortic valve prosthesis. , 2012, The Annals of thoracic surgery.

[12]  Yi Qian,et al.  A comparison of medical image segmentation methods for cerebral aneurysm computational hemodynamics , 2011, 2011 4th International Conference on Biomedical Engineering and Informatics (BMEI).

[13]  G. Hillis,et al.  64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis , 2008, Heart.

[14]  Anthony J. Yezzi,et al.  Modified curvature motion for image smoothing and enhancement , 1998, IEEE Trans. Image Process..

[15]  Roman Fischbach,et al.  Left ventricular function studied with MDCT , 2006, European Radiology.

[16]  Elie Bretin,et al.  A modified phase field approximation for mean curvature flow with conservation of the volume , 2009, 0904.0098.

[17]  H. Wei,et al.  Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard , 2009, European Radiology.

[18]  Bénédicte Belge,et al.  Characterization of Acute and Chronic Myocardial Infarcts by Multidetector Computed Tomography: Comparison With Contrast-Enhanced Magnetic Resonance , 2006, Circulation.

[19]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[20]  H. Teshima,et al.  Detection of pannus by multidetector-row computed tomography. , 2003, The Annals of thoracic surgery.

[21]  H. Teshima,et al.  Dysfunction of an ATS valve in the aortic position: the first reported case caused by pannus formation , 2005, Journal of Artificial Organs.

[22]  Henry R. Halperin,et al.  Contrast-Enhanced Multidetector Computed Tomography Viability Imaging After Myocardial Infarction: Characterization of Myocyte Death, Microvascular Obstruction, and Chronic Scar , 2006, Circulation.

[23]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[24]  H. Teshima,et al.  Usefulness of a multidetector-row computed tomography scanner for detecting pannus formation. , 2004, The Annals of thoracic surgery.

[25]  Y. Eshet,et al.  The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: initial experience. , 2008, AJR. American journal of roentgenology.

[26]  Douglas L. Jones,et al.  Line and boundary detection in speckle images , 1998, IEEE Trans. Image Process..

[27]  N. Paul,et al.  Perioperative β-Blockers : Use With Caution Perioperative β Blockers in Patients Having Non-Cardiac Surgery : A Meta-Analysis , 2010 .

[28]  Elmar Spuentrup,et al.  Assessment of myocardial viability in reperfused acute myocardial infarction using 16-slice computed tomography in comparison to magnetic resonance imaging. , 2005, Journal of the American College of Cardiology.

[29]  D J Wheatley,et al.  Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses. , 1991, The New England journal of medicine.

[30]  Yazhu Chen,et al.  A diffusion stick method for speckle suppression in ultrasonic images , 2004, Pattern Recognit. Lett..