Estimation of the performance of multiple active neutron interrogation signatures for detecting shielded HEU

A comprehensive modeling study has been carried out to evaluate the utility of multiple active neutron interrogation signatures for detecting shielded highly enriched uranium (HEU). The modeling effort focused on varying HEU masses from 1 kg to 20 kg; varying types of shields including cement, wood, polyethylene, aluminum, and steel; varying depths of the HEU in the shields, and varying engineered shields immediately surrounding the HEU including steel, lead, and cadmium. Neutron and gamma-ray signatures were the focus of the study and false negative detection probabilities versus measurement time were used as a performance metric. To facilitate comparisons among different approaches an automated method was developed to generate receiver operating characteristic (ROC) curves for different sets of model variables for multiple background count rate conditions. This paper summarizes results or the analysis, including laboratory benchmark comparisons between simulations and experiments.

[1]  M. Chernyshova,et al.  A single-shot nanosecond neutron pulsed technique for the detection of fissile materials , 2012 .

[2]  S. Thompson,et al.  Parametric evaluation of active neutron interrogation for the detection of shielded highly-enriched uranium in the field , 2011, IEEE Nuclear Science Symposium Conference Record.

[3]  James E. Doyle Nuclear Safeguards, Security and Nonproliferation: Achieving Security with Technology and Policy , 2008 .

[4]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[5]  A. Caffrey,et al.  Chemical warfare agent and high explosive identification by spectroscopy of neutron-induced gamma rays , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[6]  R. Commisso,et al.  An analysis of Intense Pulsed Active Detection (IPAD) for the detection of special nuclear materials , 2011, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[7]  K. A. Jordan,et al.  Detection of 235U in hydrogenous cargo with Differential Die-Away Analysis and optimized neutron detectors , 2007 .

[8]  M. R. Accatino,et al.  Comparison of tests with14-MeV neutrons to a Monte Carlo model for interrogation of thick cargos for clandestine fissionable materials , 2006 .

[9]  R. Mayer,et al.  Detection of thermal-induced prompt fission neutrons of highly-enriched uranium: A position sensitive technique , 2009 .

[10]  Steve Fetter,et al.  Detecting nuclear warheads , 1990 .

[11]  C.E. Moss,et al.  Neutron detectors for active interrogation of highly enriched uranium , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[12]  D. Chichester,et al.  Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Fissionable Material , 2008, IEEE Transactions on Nuclear Science.

[13]  C. Hagmann,et al.  A kinematically beamed, low energy pulsed neutron source for active interrogation , 2004 .

[14]  J. L. Jones,et al.  Pulsed photoneutron interrogation: The GNT demonstration system , 1994 .

[15]  Scott J. Thompson,et al.  Rattling nucleons: New developments in active interrogation of special nuclear material , 2012 .

[16]  Arlyn J. Antolak,et al.  SIMULATION OF CARGO CONTAINER INTERROGATION BY D-D NEUTRONS , 2007 .

[17]  L. G. Blackwood,et al.  Idaho Explosives Detection System , 2004 .

[18]  David L. Chichester,et al.  Addressing different active neutron interrogation signatures from fissionable material , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[19]  P. Peerani,et al.  Special nuclear material detection with a mobile multi-detector system , 2012 .

[20]  Tsahi Gozani,et al.  Linac based photofission inspection system employing novel detection concepts , 2011 .

[21]  Tsahi Gozani,et al.  Neutron threshold activation detectors (TAD) for the detection of fissions , 2011 .

[22]  Frank H. Ruddy,et al.  Low-background detection of fission neutrons produced by pulsed neutron interrogation , 2009 .

[23]  C.E. Moss,et al.  Comparison of Active Interrogation Techniques , 2006, IEEE Transactions on Nuclear Science.