A Hybrid Mock Circulatory System: Testing a Prototype Under Physiologic and Pathological Conditions

Hydraulic models of circulation are used to test mechanical heart assist devices and for research and training purposes. However, when compared with numerical models, they are rather expensive and often not sufficiently flexible or accurate. Flexibility and accuracy can be improved by merging numerical models with physical models, thus obtaining a hybrid model where numerical and physical sections are connected by an electrohydraulic interface.This concept is applied here to represent left ventricular function. The resulting hybrid model is inserted into the existing closed loop model of circulation. The hybrid model reproduces ventricular function by a variable elastance numerical model. Its interaction with the hydraulic sections is governed by measuring left atrial and systemic arterial pressures and computing the left ventricular output flow by the resolution of the corresponding equations. This signal is used to control a flow generator reproduced by a gear pump driven by a DC motor.Results obtained under different circulatory conditions demonstrate the behavior of the ventricular model on the pressure-volume plane and report the trend of the main hemodynamic variables.

[1]  J D Thomas,et al.  Numeric modeling of the cardiovascular system with a left ventricular assist device. , 1999, ASAIO journal.

[2]  C De Lazzari,et al.  A Hybrid (Numerical-physical) Model of the Left Ventricle , 2001, The International journal of artificial organs.

[3]  C De Lazzari,et al.  IABP Assistance: A Test Bench for the Analysis of its Effects on Ventricular Energetics and Hemodynamics , 2001, The International journal of artificial organs.

[4]  H Suga,et al.  Total mechanical energy of a ventricle model and cardiac oxygen consumption. , 1979, The American journal of physiology.

[5]  C De Lazzari,et al.  A computer controlled mock circulatory system for mono- and biventricular assist device testing. , 1998, The International journal of artificial organs.

[6]  H Reul,et al.  Compact Mock Loops of the Systemic and Pulmonary Circulation for Blood Pump Testing , 1992, The International journal of artificial organs.

[7]  R. Applegate,et al.  Cardiac Contraction and the Pressure-Volume Relationship , 1990 .

[8]  J R Pepper,et al.  Development of mock circulation models for the assessment of counterpulsation systems. , 1991, Cardiovascular research.

[9]  Stewart J. Woodruff,et al.  Influence of Gravity on Cardiac Performance , 2004, Annals of Biomedical Engineering.

[10]  C De Lazzari,et al.  Technical standards for medical devices. Assisted circulation devices. , 1997, Technology and health care : official journal of the European Society for Engineering and Medicine.

[11]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[12]  E Wolner,et al.  A Modular Mock Circulation for Hydromechanical Studies on Valves, Stenoses, Vascular Grafts and Cardiac Assist Devices , 1992, The International journal of artificial organs.

[13]  P M Portner,et al.  A sophisticated electromechanical ventricular simulator for ventricular assist system testing. , 1991, ASAIO transactions.

[14]  Jean Charles Gilbert,et al.  Determinants of left ventricular filling and of the diastolic pressure-volume relation. , 1989, Circulation research.

[15]  G J Verkerke,et al.  Development of a numerical simulation model of the cardiovascular system. , 1997, Artificial organs.

[16]  F. Clemente,et al.  A Physical Model of the Human Systemic Arterial Tree , 2000, The International journal of artificial organs.

[17]  F. Clemente,et al.  Mono and Bi-ventricular Assistance: Their Effect on Ventricular Energetics , 2001, The International journal of artificial organs.

[18]  G Ferrari,et al.  A modular numerical model of the cardiovascular system for studying and training in the field of cardiovascular physiopathology. , 1992, Journal of biomedical engineering.