Assessing speech recognition in noise for listeners with a signal processor hearing aid.

Hearing aids with signal processors use advanced circuitry to enhance speech recognition in noise. The effectiveness of these processors has not been well established. The purpose of this study was to evaluate performance on a speech recognition in noise task for listeners wearing a Zeta signal processor aid with the processor turned on and with the processor turned off. In addition, comparisons were made to performance while unaided and aided with a conventional hearing aid. A simple adaptive procedure and a psychometric function were the procedures used. Results for normal-hearing subjects indicate performance was usually better without a hearing aid. Performance when aided was similar for the processor on and the conventional aid. Performance in both of these conditions was clearly better than with the signal processor off. Although results for the hearing-impaired subjects varied widely, there was a trend for better performance with the conventional aid and with the signal processor on than for the signal processor off condition.

[1]  H Levitt,et al.  Use of a sequential strategy in intelligibility testing. , 1967, The Journal of the Acoustical Society of America.

[2]  D J Van Tasell,et al.  Speech recognition threshold in noise: effects of hearing loss, frequency response, and speech materials. , 1987, Journal of speech and hearing research.

[3]  R Plomp,et al.  A model for the speech-reception threshold in noise without and with a hearing aid. , 1982, Scandinavian audiology. Supplementum.

[4]  A. M. Mimpen,et al.  Speech-reception threshold for sentences as a function of age and noise level. , 1979, The Journal of the Acoustical Society of America.

[5]  D D Dirks,et al.  A procedure for quantifying the effects of noise on speech recognition. , 1982, The Journal of speech and hearing disorders.

[6]  Richard H. Wilson,et al.  Measurements of Auditory Thresholds for Speech Stimuli , 1983 .

[7]  L K Stein,et al.  Listener‐Assessed Intelligibility of a Hearing Aid Self‐Adaptive Noise Filter , 1984, Ear and hearing.

[8]  K Welzl-Müller,et al.  Signal-to-noise threshold with and without hearing aid. , 1984, Scandinavian audiology.

[9]  W. J. Langford Statistical Methods , 1959, Nature.

[10]  R Plomp,et al.  The effect of a hearing aid on the speech-reception threshold of hearing-impaired listeners in quiet and in noise. , 1983, The Journal of the Acoustical Society of America.

[11]  R. L. Wegel,et al.  The Auditory Masking of One Pure Tone by Another and its Probable Relation to the Dynamics of the Inner Ear , 1924 .

[12]  D A Fabry,et al.  Effects of an adaptive filter hearing aid on speech recognition in noise by hearing-impaired subjects. , 1988, Ear and hearing.