Measurements of three-dimensional mean flame surface area ratio in turbulent premixed Bunsen flames

Abstract A data processing scheme with particular emphasis on proper flame contour smoothing is developed and applied to measure the three-dimensional mean flame surface area ratio in turbulent premixed flames. The scheme is based on the two-sheet imaging technique such that the mean flame surface area ratio is an average within a window covering a finite section of the turbulent flame brush. This is in contrast to the crossed-plane tomograph technique which applies only to a line. Two sets of Bunsen flames have been investigated in this work with the turbulent Reynolds number up to 4000 and the Damkohler number ranging from less than unity to close to 10. The results show that three-dimensional effects are substantial. The measured three-dimensional mean flame surface area ratio correlates well with a formula similar to the Zimont model for turbulent burning velocity but with different model constants. Also, the mean flame surface area ratio displays a weak dependency on turbulence intensity but a strong positive dependency on the turbulence integral length scale.