Effects of I/Q mismatch on measurement of periodic movement using a Doppler radar sensor
暂无分享,去创建一个
In this paper, the effect of I/Q mismatch in a 5.8 GHz direct-conversion quadrature Doppler radar sensor detecting periodic movement is studied. The measured movement amplitude under specific I/Q amplitude or phase mismatch is affected by the residual phase, which is determined by the nominal distance from the target to the antenna. It was found that there exist optimal residual phases minimizing the degradation of detection accuracy caused by amplitude and phase mismatches. Experiments were conducted to verify the theory.
[1] Jenshan Lin,et al. Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring , 2004, IEEE Transactions on Microwave Theory and Techniques.
[2] Jenshan Lin,et al. Non-Contact Measurement of Periodic Movements by a 22-40GHz Radar Sensor Using Nonlinear Phase Modulation , 2007, 2007 IEEE/MTT-S International Microwave Symposium.
[3] Changzhi Li,et al. Random Body Movement Cancellation in Doppler Radar Vital Sign Detection , 2008, IEEE Transactions on Microwave Theory and Techniques.