Performance tests of a new non-invasive sensor unit and ultrasound electronics

Abstract Industrial applications involving pulsed ultrasound instrumentation require complete non-invasive setups due to high temperatures, pressures and possible abrasive fluids. Recently, new pulser-receiver electronics and a new sensor unit were developed by Flow-Viz. The complete sensor unit setup enables non-invasive Doppler measurements through high grade stainless steel. In this work a non-invasive sensor unit developed for one inch pipes (22.5 mm ID) and two inch pipes (48.4 mm ID) were evaluated. Performance tests were conducted using a Doppler string phantom setup and the Doppler velocity results were compared to the moving string target velocities. Eight different positions along the pipe internal diameter (22.5 mm) were investigated and at each position six speeds (0.1–0.6 m/s) were tested. Error differences ranged from 0.18 to 7.8% for the tested velocity range. The average accuracy of Doppler measurements for the 22.5 mm sensor unit decreased slightly from 1.3 to 2.3% across the ultrasound beam axis. Eleven positions were tested along the diameter of the 48.4 mm pipe (eight positions covered the pipe radius) and five speeds were tested (0.2–0.6 m/s). The average accuracy of Doppler measurements for the 48.4 mm sensor unit was between 2.4 and 5.9%, with the lowest accuracy at the point furthest away from the sensor unit. Error differences varied between 0.07 and 11.85% for the tested velocity range, where mostly overestimated velocities were recorded. This systematic error explains the higher average error difference percentage when comparing the 48.4 mm (2.4–5.9%) and 22.5 mm (1.3–2.3%) sensor unit performance. The overall performance of the combined Flow-Viz system (electronics, software, sensor) was excellent as similar or higher errors were typically reported in the medical field. This study has for the first time validated non-invasive Doppler measurements through high grade stainless steel pipes by using an advanced string phantom setup.

[1]  Rainer Haldenwang,et al.  Optimisation of Pulsed Ultrasonic Velocimetry system and transducer technology for industrial applications. , 2013, Ultrasonics.

[2]  Rainer Haldenwang,et al.  Measurement and analysis of flow behaviour in complex geometries using the Ultrasonic Velocity Profiling (UVP) technique , 2011 .

[3]  C. Atzeni,et al.  Spectral velocity profiles for detailed ultrasound flow analysis , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Kjell Lindström,et al.  A microcirculation phantom for performance testing of blood perfusion measurement equipment , 1995 .

[5]  Andrew R. Walker,et al.  Evaluating doppler devices using a moving string test target , 1982, Journal of clinical ultrasound : JCU.

[6]  F. Scala Mass transfer around freely moving active particles in the dense phase of a gas fluidized bed of inert particles , 2007 .

[7]  Johan Wiklund,et al.  Methodology for in-line rheology by ultrasound Doppler velocity profiling and pressure difference techniques , 2007 .

[8]  L. William Varner,et al.  Geometrical Spectrum Broadening in Ultrasonic Doppler Systems , 1977, IEEE Transactions on Biomedical Engineering.

[9]  Johan Wiklund,et al.  Application of in-line ultrasound Doppler-based UVP–PD rheometry method to concentrated model and industrial suspensions , 2008 .

[10]  Donald W. Baker,et al.  Physical characteristics and mathematical modelling of the pulsed ultrasonic flowmeter , 2006, Medical and biological engineering.

[11]  J M Thijssen,et al.  Performance testing of medical echo/Doppler equipment. , 2002, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[12]  Peter R. Hoskins,et al.  Contribution ASSESSMENT OF SPECTRAL DOPPLER IN PRECLINICAL ULTRASOUND USING A SMALL-SIZE ROTATING PHANTOM , 2013 .

[13]  Yasushi Takeda,et al.  Measurement of velocity profile of mercury flow by ultrasound doppler shift method , 1987 .

[14]  Rainer Haldenwang,et al.  Flow-VizTM –A fully integrated and commercial in-line fluid characterization system for industrial applications , 2014 .

[15]  W. Holland,et al.  Tendon displacement assessment by pulsed Doppler tissue imaging: validation with a reciprocating string test target. , 1999, Ultrasound in medicine & biology.

[16]  S F Stewart,et al.  Effects of transducer, velocity, Doppler angle, and instrument settings on the accuracy of color Doppler ultrasound. , 2001, Ultrasound in medicine & biology.

[17]  Piero Tortoli,et al.  Embedded Doppler system for industrial in-line rheometry , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  P. Tortoli,et al.  A programmable real-time system for development and test of new ultrasound investigation methods , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  Rainer Haldenwang,et al.  DEVELOPMENT OF AN INDUSTRIAL UVP+PD BASED RHEOMETER-OPTIMISATION OF UVP SYSTEM AND TRANSDUCER TECHNOLOGY , 2012 .

[20]  Johan Wiklunda,et al.  Application of in-line ultrasound Doppler based UVP-PD method to concentrated model and industrial suspensions , 2010 .

[21]  Paul Slatter,et al.  Rheological Characterization of Highly Concentrated Mineral Suspensions Using Ultrasound Velocity Profiling with Combined Pressure Difference Method , 2008 .

[22]  George S. K. Wong,et al.  Speed of sound in pure water as a function of temperature , 1993 .