A Quasi-2-Dimensional Model for Respiration of the Cornea With Soft Contact Lens Wear

Purpose Because neither the human cornea nor a soft contact lens (SCL) is of constant thickness, corneal oxygenation varies locally. To quantify the importance of cornea/SCL thickness variations on oxygen demand, we develop a quasi-2-dimensional (2D) respiration model that accounts for aerobic and anaerobic metabolism and bicarbonate buffering. Methods Because metabolism is critical to oxygen demand, we extend the 1-dimensional (1D), 6-layer oxygen metabolic model of Chhabra et al. Lateral diffusion is shown to be negligible. Accordingly, we adopt the 1D reactive-diffusion metabolic model but apply it locally along the cornea/lens extent. This “quasi-2D” approximation permits 2D assessment of oxygen consumption, including the effects of carbon dioxide, glucose, and lactate, bicarbonate, and hydrogen ions. We use both an oxygen deficiency factor and an excess lactate factor to gauge corneal health after accounting for both cornea and contact lens thickness variations. Results The quasi-2D respiration model provides quantitative spatial resolution of corneal oxygenation with minimal expenditure of computation time. When only aerobic oxygen loss is included, our quasi-2D approach is in excellent agreement with the fully 2D results of Alvord et al. However, the quasi-2D model predicts 2D concentration profiles of glucose, lactate ions, bicarbonate ions, hydrogen ions, and carbon dioxide, as well as oxygen. Neglect of metabolic reactions and/or thickness variations leads to inaccurate prediction of oxygen demand, especially near the lens periphery. Conclusions The quasi-2D respiration model indicates that lateral thickness variations and respiration kinetics are critical for assessing on-eye physiologic performance of an SCL. We find that oxygen deficiency factor and excess lactate factor are useful indices to gauge corneal hypoxia. A user-friendly computer program of the quasi-2D respiration model is available for lens design.

[1]  C. Radke,et al.  Oxygen-deficient metabolism and corneal edema , 2011, Progress in Retinal and Eye Research.

[2]  P. Bates,et al.  Coupled 1D–Quasi-2D Flood Inundation Model with Unstructured Grids , 2010 .

[3]  Ned Djilali,et al.  Reduced-dimensional models for straight-channel proton exchange membrane fuel cells , 2010 .

[4]  J. Prausnitz,et al.  Modeling Corneal Metabolism and Oxygen Transport During Contact Lens Wear , 2009, Optometry and vision science : official publication of the American Academy of Optometry.

[5]  I. Pech,et al.  Environmental risk of dissolved oxygen depletion of diverted flood waters in river polder systems--a quasi-2D flood modelling approach. , 2009, The Science of the total environment.

[6]  K. Lindenschmidt Quasi-2D Approach in Modeling the Transport of Contaminated Sediments in Floodplains during River Flooding—Model Coupling and Uncertainty Analysis , 2008 .

[7]  J. González-Méijome,et al.  Determination of Oxygen Permeability in Soft Contact Lenses Using a Polarographic Method: Estimation of Relevant Physiological Parameters , 2008 .

[8]  J. Prausnitz,et al.  Polarographic Method for Measuring Oxygen Diffusivity and Solubility in Water-Saturated Polymer Films: Application to Hypertransmissible Soft Contact Lenses , 2008 .

[9]  N. Brennan Oxygen modeling of the peripheral cornea. , 2008, Cornea.

[10]  C. F. Morgan,et al.  Corneal Oxygen Distribution With Contact Lens Wear , 2007, Cornea.

[11]  Adam Z. Weber,et al.  Effects of Membrane- and Catalyst-Layer-Thickness Nonuniformities in Polymer-Electrolyte Fuel Cells , 2007 .

[12]  S. Beale,et al.  Numerical Predictions of Transport Phenomena in a Proton Exchange Membrane Fuel Cell , 2005 .

[13]  Noel A Brennan,et al.  Beyond Flux: Total Corneal Oxygen Consumption as an Index of Corneal Oxygenation During Contact Lens Wear , 2005, Optometry and vision science : official publication of the American Academy of Optometry.

[14]  N. Brennan Corneal oxygenation during contact lens wear: comparison of diffusion and EOP‐based flux models , 2005, Clinical & experimental optometry.

[15]  M. Monticelli,et al.  The Effect of Water Hydraulic Permeability on the Settling of a Soft Contact Lens on the Eye , 2005, Current eye research.

[16]  A. Weber,et al.  Modeling transport in polymer-electrolyte fuel cells. , 2004, Chemical reviews.

[17]  T. Simpson,et al.  Contact Lens-Induced Corneal Swelling and Surface Changes Measured with the Orbscan II Corneal Topographer , 2004, Optometry and vision science : official publication of the American Academy of Optometry.

[18]  B. Weissman,et al.  Is contact lens "T" still important? , 2004, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[19]  D. Sweeney Clinical Signs of Hypoxia with High-Dk Soft Lens Extended Wear: Is the Cornea Convinced? , 2003, Eye & contact lens.

[20]  P. Soni,et al.  Estimation of human corneal oxygen consumption by noninvasive measurement of tear oxygen tension while wearing hydrogel lenses. , 2002, Investigative ophthalmology & visual science.

[21]  N. Brennan A Model of Oxygen Flux Through Contact Lenses , 2001, Cornea.

[22]  J. Bonanno,et al.  Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. , 1999, Optometry and vision science : official publication of the American Academy of Optometry.

[23]  N. Efron,et al.  Distribution of Oxygen Across the Surface of the Human Cornea during Soft Contact Lens Wear , 1996, Optometry and vision science : official publication of the American Academy of Optometry.

[24]  J. Bonanno,et al.  Direct noninvasive measurement of tear oxygen tension beneath gas-permeable contact lenses in rabbits. , 1996, Investigative ophthalmology & visual science.

[25]  P. Erickson,et al.  Effects of hydrogel lens transmissibility profiles on local corneal swelling during eye closure. , 1996, Optometry and vision science : official publication of the American Academy of Optometry.

[26]  I. Fatt,et al.  The point-to-point variation of oxygen delivery to a cornea covered by a hydrogel contact lens in the open eye , 1994 .

[27]  I. Fatt,et al.  Contact Lenses Affect Corneal Stromal pH , 1993, Optometry and vision science : official publication of the American Academy of Optometry.

[28]  I. Fatt,et al.  Areal differences in oxygen supply to a cornea wearing an optically powered hydrogel contact lens. , 1993, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc.

[29]  P. Herse,et al.  Topographical corneal edema , 1993, Acta ophthalmologica.

[30]  I. Fatt Is there a problem in EOP lnd , 1993 .

[31]  N A Brennan,et al.  Clinical application of the oxygen transmissibility of powered contact lenses. , 1991, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc.

[32]  C. Lyons,et al.  Symptomatic nocturnal lagophthalmos. , 1990, Australian and New Zealand journal of ophthalmology.

[33]  N. Brennan,et al.  Corneal pathophysiology with contact lens wear. , 1990, Survey of ophthalmology.

[34]  D. Maurice,et al.  The pH in the precorneal tear film and under a contact lens measured with a fluorescent probe. , 1990, Experimental eye research.

[35]  R M Hill,et al.  Buffering in human tears: pH responses to acid and base challenge. , 1989, Investigative ophthalmology & visual science.

[36]  L. Carney,et al.  Corneal Oxygen Availability during Contact Lens Wear: A Comparison of Methodologies , 1988, American journal of optometry and physiological optics.

[37]  L. Carney,et al.  Critical oxygen requirements to avoid oedema of the central and peripheral cornea , 1987, Acta ophthalmologica.

[38]  T. Ling Osmotically Induced Central and Peripheral Corneal Swelling in the Cat , 1987, American journal of optometry and physiological optics.

[39]  Nathan Efron,et al.  In search of the critical oxygen requirement of the cornea , 1987 .

[40]  Michael M. Goldman,et al.  Effect of Soft Lens Power on Peripheral Corneal Edema , 1986, American journal of optometry and physiological optics.

[41]  N. Efron,et al.  Oxygen uptake profile of the human cornea , 1986 .

[42]  B. Holden,et al.  Topographical corneal oedema , 1985, Acta ophthalmologica.

[43]  K. Polse Central and Peripheral Corneal Swelling Accompanying Soft Lens Extended Wear , 1985, American journal of optometry and physiological optics.

[44]  G. Wilson,et al.  Polarography: an oxygen survey correlating oxygen transmissibility to "EOP" values. , 1984, Investigative ophthalmology & visual science.

[45]  B. Holden,et al.  Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. , 1984, Investigative ophthalmology & visual science.

[46]  K A Polse,et al.  Corneal response to rigid and hydrogel lenses during eye closure. , 1984, Investigative ophthalmology & visual science.

[47]  B. Holden,et al.  Comparative physiologic performance of polymethyl methacrylate and gas-permeable contact lenses. , 1984, Archives of ophthalmology.

[48]  B. Weissman,et al.  Human Corneal Oxygen Flux under Soft Contact Lenses , 1982, American journal of optometry and physiological optics.

[49]  S D Klyce,et al.  Stromal lactate accumulation can account for corneal oedema osmotically following epithelial hypoxia in the rabbit. , 1981, The Journal of physiology.

[50]  W. Sammons Thin lens design and average thickness , 1981 .

[51]  Morton M. Denn,et al.  Process Fluid Mechanics , 1979 .

[52]  G. Wilson Hydrogel Lens Power and Oxygen Transmissibility , 1979, American journal of optometry and physiological optics.

[53]  K. Polse,et al.  Oxygen tension under a contact lens. , 1979, Investigative ophthalmology & visual science.

[54]  H. Kaufman,et al.  Corneal exposure during sleep (nocturnal lagophthalmos). , 1977, Archives of ophthalmology.

[55]  M S Borcherding,et al.  Proteoglycans and collagen fibre organization in human corneoscleral tissue. , 1975, Experimental eye research.

[56]  I. Fatt,et al.  Oxygen tension distributions in the cornea: a re-examination. , 1974, Experimental eye research.

[57]  S. Pye,et al.  STEADY STATE DISTRIBUTION OF OXYGEN AND CARBON DIOXIDE IN THE IN VIVO CORNEA OF AN EYE COVERED BY A GAS‐PERMEABLE CONTACT LENS* , 1969, American journal of optometry and archives of American Academy of Optometry.

[58]  I. Fatt,et al.  Steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. II. The open eye in nitrogen and the covered eye. , 1968, Experimental eye research.

[59]  Lagophthalmos During SLEEPt Lagophthalmos during sleep. , 1967, The British journal of ophthalmology.

[60]  R. Hill,et al.  OXYGEN DEPRIVATION OF THE CORNEA BY CONTACT LENSES AND LID CLOSURE. , 1964, American journal of optometry and archives of American Academy of Optometry.

[61]  R. Hill,et al.  OXYGEN MEASUREMENTS UNDER A CONTACT LENS. , 1964, American journal of optometry and archives of American Academy of Optometry.

[62]  G. K. Smelser,et al.  Physiological Changes in Cornea orneu induced by Contact Lenses , 1955 .

[63]  D. Maurice,et al.  Swelling of the Cornea in vivo after the Destruction of its Limiting Layers * , 1951, The British journal of ophthalmology.

[64]  Berkeley California Disclaimer,et al.  University of California , 1886, The American journal of dental science.

[65]  Olivier Lottin,et al.  Modelling of the operation of Polymer Exchange Membrane Fuel Cells in the presence of electrodes flooding , 2009 .

[66]  Anne de Weme Quasi-2D modelling of the River Elbe : A comparison of different inundation models for flood risk assessment within a decision support system , 2005 .

[67]  M. Refojo,et al.  Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties. , 2004, Biomaterials.

[68]  BSc. Mciwem Modelling Flood Inundation of Urban Areas in the UK Using 2D / 1D Hydraulic Models , 2004 .

[69]  P B Morgan,et al.  The oxygen performance of contemporary hydrogel contact lenses. , 1998, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[70]  I. Fatt,et al.  New physiological paradigms to assess the effect of lens oxygen transmissibility on corneal health. , 1996, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc.

[71]  Irving Fatt,et al.  A new oxygen transmissibility concept for hydrogel contact lenses , 1993 .

[72]  W. Benjamin EOP and Dk/L: the quest for hyper transmissibility. , 1993, Journal of the American Optometric Association.

[73]  B. Holden,et al.  Limited lateral spread of stromal edema in the human cornea fitted with a ('donut') contact lens with a large central aperture. , 1988, Current eye research.

[74]  G J Andrasko,et al.  Corneal deswelling response to hard and hydrogel extended wear lenses. , 1986, Investigative ophthalmology & visual science.

[75]  R. Pearson How thick is a contact lens , 1986 .

[76]  I. Fatt,et al.  Spatial distribution of oxygen in the cornea of a closed eye wearing a gas permeable contact lens. , 1985, Current eye research.

[77]  L. Carney,et al.  Oxygen levels beneath the closed eyelid. , 1979, Investigative ophthalmology & visual science.

[78]  Irving Fatt,et al.  Physiology of the eye : an introduction to the vegetative functions , 1978 .

[79]  I. Fatt,et al.  The steady-state distribution of oxygen and carbon dioxide in the in vivo cornea. I. The open eye in air and the closed eye. , 1968, Experimental eye research.

[80]  G K SMELSER,et al.  Physiological changes in cornea induced by contact lenses. , 1955, A.M.A. archives of ophthalmology.