Non-invasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurements.

The non-linear elastic response of arteries implies that their mechanical properties depend strongly on blood pressure. Thus, dynamic measurements of both the diameter and pressure curves over the whole cardiac cycle are necessary to characterise properly the elastic behaviour of an artery. We propose a novel method of estimating these mechanical properties based on the analysis of the arterial diameter against pressure curves derived from ultrasonic and photoplethysmographic measurements. An ultrasonic echo tracking device has been developed that allows continuous recording of the internal diameter of peripheral arteries. It measures the diameter 300 times per second with a resolution of 2.5 microns. This system is linked to a commercially available light-plethysmograph which continuously records the finger arterial pressure (0.25 kPa accuracy). Because of the finite pulse wave velocity, the separation between the diameter and the pressure measurement sites causes a hysteresis to appear in the recorded diameter-pressure curve. Using a model based on haemodynamic considerations, the delay between the diameter variations and the finger arterial pressure is first eliminated. As the pulse wave velocity depends on the pressure, the delay is determined for each pressure value. The relationship between pressure and diameter is then described by a non-linear mathematical expression with three parameters, which best fits the recorded data. The dynamic local behaviour of the vessel is fully characterised by these parameters. Compliance, distensibility and pulse wave velocity can then be calculated at each pressure level. Thus, the mechanical behaviour of peripheral human arteries can now be characterised non-invasively over the pressure range of the whole cardiac cycle. The results obtained in vivo on human radial and brachial arteries show that a thorough analysis of the compliance-pressure curves and their modifications (curving, shift) is needed in order to compare two different vessels in a meaningful way.

[1]  P. Niederer,et al.  A viscoelastic model for use in predicting arterial pulse waves. , 1980, Journal of biomechanical engineering.

[2]  Albert S. Kobayashi,et al.  Large Deformation Analysis of the Arterial Cross Section , 1971 .

[3]  D. Hokanson,et al.  A phase-locked echo tracking system for recording arterial diameter changes in vivo. , 1972, Journal of applied physiology.

[4]  J. Karemaker,et al.  Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre. , 1988, Cardiovascular research.

[5]  G. Langewouters,et al.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. , 1984, Journal of biomechanics.

[6]  P. Niederer A molecular study of the mechanical properties of arterial vessel walls , 1974 .

[7]  M. Anliker,et al.  Influence of Flow and Pressure on Wave Propagation in the Canine Aorta , 1973, Circulation research.

[8]  Y. Kivity,et al.  Nonlinear wave propagation in viscoelastic tubes: application to aortic rupture. , 1974, Journal of biomechanics.

[9]  V. Mooser,et al.  Effect of cold pressor test on the internal diameter of the radial artery. , 1989, American journal of hypertension.

[10]  Katsuyuki Yamamoto,et al.  Non-invasive ultrasonic measurement of the elastic properties of the human abdominal aorta. , 1986, Cardiovascular research.

[11]  Differenzierung zwischen normalen und pathologischen Strömungsverhältnissen im arteriellen Kreislauf mittels gepulstem Ultraschall , 1980 .

[12]  Influence of geometric taper on the derivation of the true propagation coefficient using a three point method. , 1988, Journal of biomechanics.

[13]  T. J. Werff Significant parameters in arterial pressure and velocity development. , 1974 .

[14]  R. Busse,et al.  Pressure-diameter relationships of segments of human finger arteries. , 1986, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[15]  R S Reneman,et al.  Assessment of the distensibility of superficial arteries. , 1990, Ultrasound in medicine & biology.

[16]  K H Wesseling,et al.  Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (the Finapres). , 1985, Anesthesiology.

[17]  Lysle H. Peterson,et al.  Mechanical Properties of Arteries in Vivo , 1960 .

[18]  S M Finkelstein,et al.  Arterial Vascular Compliance Response to Vasodilators by Fourier and Pulse Contour Analysis , 1988, Hypertension.

[19]  H Handa,et al.  Stiffness and elastic behavior of human intracranial and extracranial arteries. , 1980, Journal of biomechanics.

[20]  J. van Egmond,et al.  Invasive v. non-invasive measurement of arterial pressure. Comparison of two automatic methods and simultaneously measured direct intra-arterial pressure. , 1985, British journal of anaesthesia.

[21]  J. Meister,et al.  Non‐invasive measurement of internal diameter of peripheral arteries during the cardiac cycle , 1988, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[22]  W. Abbott,et al.  Postsurgical changes in arterial compliance. , 1984, Archives of surgery.

[23]  Jean-Jacques Meister Mesure par échographie Doppler et modélisation théorique de l"effet de troubles cardiaques sur la pression et le débit artériels , 1983 .

[24]  G. L’italien,et al.  Noninvasive measurements of nonlinear arterial elasticity. , 1986, The American journal of physiology.

[25]  D. Bergel,et al.  The dynamic elastic properties of the arterial wall , 1961, The Journal of physiology.

[26]  H. Smulyan,et al.  Forearm arterial distensibility in systolic hypertension. , 1984, Journal of the American College of Cardiology.

[27]  E. Bradley,et al.  Length-force and volume-pressure relationships of arteries. , 1977 .

[28]  H. Westling,et al.  Vasoactive drugs and elastic properties of human arteries in vivo, with special reference to the action of nitroglycerine. , 1984, European heart journal.

[29]  D H Groves,et al.  A digital technique for tracking moving interfaces. , 1982, Ultrasound in medicine & biology.

[30]  Allen L. King,et al.  Pressure‐Volume Relation for Cylindrical Tubes with Elastomeric Walls: The Human Aorta , 1946 .

[31]  K H Wesseling,et al.  Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger. , 1985, Cardiovascular research.