Electrode impedance analysis of chronic tungsten microwire neural implants: understanding abiotic vs. biotic contributions
暂无分享,去创建一个
Justin C. Sanchez | Abhishek Prasad | Toshikazu Nishida | Robert Dieme | Viswanath Sankar | Erin Patrick | T. Nishida | A. Prasad | V. Sankar | E. Patrick | Robert Dieme
[1] Edgard Morya,et al. Comprehensive Analysis of Tissue Preservation and Recording Quality from Chronic Multielectrode Implants , 2011, PloS one.
[2] D. Kipke,et al. Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[3] David C. Martin,et al. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays , 2005, Experimental Neurology.
[4] D. Kipke,et al. Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex. , 1999, Brain research. Brain research protocols.
[5] Mark E. Orazem,et al. Enhanced Graphical Representation of Electrochemical Impedance Data , 2006 .
[6] Daryl R Kipke,et al. Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.
[7] D. Szarowski,et al. Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.
[8] Justin C. Williams,et al. Stability of chronic multichannel neural recordings: Implications for a long-term neural interface , 1999, Neurocomputing.
[9] Patrick A Tresco,et al. Chronic response of adult rat brain tissue to implants anchored to the skull. , 2004, Biomaterials.
[10] Patrick D Wolf,et al. A fully implantable 96-channel neural data acquisition system , 2009, Journal of neural engineering.
[11] M. Sluyters-Rehbach,et al. The analysis of electrode impedances complicated by the presence of a constant phase element , 1984 .
[12] A. Levey,et al. Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration , 2009, Journal of neural engineering.
[13] M. Ward,et al. Toward a comparison of microelectrodes for acute and chronic recordings , 2009, Brain Research.
[14] E. McAdams,et al. The linear and non-linear electrical properties of the electrode-electrolyte interface , 1995 .
[15] D. Szarowski,et al. Brain responses to micro-machined silicon devices , 2003, Brain Research.
[16] Patrick A Tresco,et al. The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull. , 2007, Journal of biomedical materials research. Part A.
[17] Daryl R. Kipke,et al. Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes , 2006, IEEE Transactions on Biomedical Engineering.
[18] Justin C. Sanchez,et al. Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing , 2012, Journal of neural engineering.
[19] P. Carney,et al. Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study , 2006, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[20] David R. Wozny,et al. The electrical conductivity of human cerebrospinal fluid at body temperature , 1997, IEEE Transactions on Biomedical Engineering.
[21] R. Rennaker,et al. An economical multi-channel cortical electrode array for extended periods of recording during behavior , 2005, Journal of Neuroscience Methods.
[22] Daryl R Kipke,et al. Theoretical analysis of intracortical microelectrode recordings , 2011, Journal of neural engineering.
[23] R. A. Serway. Principles of Physics , 1994 .
[24] Z. Cohn,et al. The macrophage. , 1973, International review of cytology.
[25] Aubrey T. Dyer,et al. Electrode Failure: Tissue, Electrical, and Material Responses , 2012, IEEE Pulse.
[26] Justin C. Sanchez,et al. Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants , 2012, Journal of neural engineering.
[27] Justin C. Sanchez,et al. Corrosion of tungsten microelectrodes used in neural recording applications , 2011, Journal of Neuroscience Methods.
[28] W. Grill,et al. Electrical properties of implant encapsulation tissue , 2006, Annals of Biomedical Engineering.
[29] P. Tresco,et al. Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.