Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth

Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan) and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA) for measuring central corneal thickness (CCT), anterior chamber depth (ACD), and aqueous depth (AD). Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator. Agreement between the two devices was assessed using paired t-tests, Bland-Altman plots, and 95% limits of agreement (LoA). Results. The mean CCT, ACD, and AD measured by AL-Scan were 538.59 ± 27.37 μm, 3.70 ± 0.30 mm, and 3.16 ± 0.30 mm, respectively. The mean values obtained by the Visante OCT were 536.14 ± 26.61 μm for CCT, 3.71 ± 0.29 mm for ACD, and 3.17 ± 0.29 mm for AD. The mean CCT by the AL-Scan was higher than that obtained by the Visante AS-OCT (difference = 2.45 ± 6.07 μm, P < 0.05). The differences in ACD and AD measurements were not statistically significant. The 95% LoA of CCT, ACD, and AD were between −9.44 and 14.35 μm, −0.15 and 0.12 mm, and −0.15 and 0.12 mm, respectively. Conclusions. Since these two devices were comparable for measuring CCT, ACD, and AD, their results can be interchangeably used in the clinic.

[1]  Y. Totan,et al.  Comparison of anterior chamber depth measurements of Nidek AL-Scan and Galilei Dual Scheimpflug Analyzer. , 2015, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[2]  S. Srivannaboon,et al.  Comparison of corneal astigmatism measurements of 2 optical biometer models for toric intraocular lens selection , 2015, Journal of cataract and refractive surgery.

[3]  G. Savini,et al.  Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: Repeatability, reproducibility, and agreement , 2015, Journal of cataract and refractive surgery.

[4]  R. Yağcı,et al.  Repeatability and reproducibility of a new optical biometer in normal and keratoconic eyes , 2015, Journal of cataract and refractive surgery.

[5]  D. Mathysen,et al.  Overview of the repeatability, reproducibility, and agreement of the biometry values provided by various ophthalmic devices. , 2014, American journal of ophthalmology.

[6]  A. Kalkişim,et al.  Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents , 2014, Journal of ophthalmology.

[7]  G. Savini,et al.  Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster , 2014, British Journal of Ophthalmology.

[8]  S. Srivannaboon,et al.  Comparison of ocular biometry and intraocular lens power using a new biometer and a standard biometer , 2014, Journal of cataract and refractive surgery.

[9]  M. Labetoulle,et al.  Biometry and intraocular lens power calculation results with a new optical biometry device: Comparison with the gold standard , 2014, Journal of cataract and refractive surgery.

[10]  G. Savini,et al.  A Comparison between Scheimpflug imaging and optical coherence tomography in measuring corneal thickness. , 2013, Ophthalmology.

[11]  A. Demirok,et al.  Measurements of anterior segment parameters using three different non-contact optical devices in keratoconus patients. , 2013, International journal of ophthalmology.

[12]  E. España-Gregori,et al.  Anterior chamber depth measurement in teenagers. Comparison of two techniques , 2013 .

[13]  Qin-Mei Wang,et al.  [Repeatability and agreement of corneal thickness measurement with Pentacam Scheimpflug photography and Visante optical coherence tomography]. , 2013, [Zhonghua yan ke za zhi] Chinese journal of ophthalmology.

[14]  L. Módis,et al.  Anterior Segment Parameters Measured with 2 Optical Devices Compared to Ultrasonic Data , 2013, European journal of ophthalmology.

[15]  H. Radhakrishnan,et al.  Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCT , 2012, Cornea.

[16]  M. He,et al.  Comparison of anterior ocular segment biometry features and related factors among American Caucasians, American Chinese and mainland Chinese , 2012, Clinical & experimental ophthalmology.

[17]  Kenneth J Hoffer,et al.  Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography , 2011, Journal of cataract and refractive surgery.

[18]  Kenneth J Hoffer,et al.  Comparison of anterior segment measurements by 3 Scheimpflug tomographers and 1 Placido corneal topographer , 2011, Journal of cataract and refractive surgery.

[19]  K. Hoffer Definition of ACD. , 2011, Ophthalmology.

[20]  Sang Min Nam,et al.  Accuracy of RTVue optical coherence tomography, Pentacam, and ultrasonic pachymetry for the measurement of central corneal thickness. , 2010, Ophthalmology.

[21]  E. Gorgun,et al.  Assessment of Anterior Chamber Depth Using Visante Optical Coherence Tomography, Slitlamp Optical Coherence Tomography, IOL Master, Pentacam and Orbscan IIz , 2010, Ophthalmologica.

[22]  Shu-Wen Chang,et al.  Anterior Chamber Depth Measurement in Phakic and Pseudophakic Eyes , 2008, Optometry and vision science : official publication of the American Academy of Optometry.

[23]  T. Mimura,et al.  In vivo confocal microscopy of human cornea covered with human amniotic membrane , 2008, Japanese Journal of Ophthalmology.

[24]  D. Lam,et al.  Repeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography. , 2007, Investigative ophthalmology & visual science.

[25]  L. Richiardi,et al.  Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry. , 2007, American journal of ophthalmology.

[26]  Gabor Nemeth,et al.  Assessment and reproducibility of anterior chamber depth measurement with anterior segment optical coherence tomography compared with immersion ultrasonography , 2007, Journal of cataract and refractive surgery.

[27]  S. K. Seah,et al.  Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography , 2007, British Journal of Ophthalmology.

[28]  Wolfgang Drexler,et al.  Comparison of partial coherence interferometers: Acmaster versus laboratory prototype. , 2006, Journal of refractive surgery.

[29]  E. Dai,et al.  Pediatric central corneal thickness variation among major ethnic populations. , 2006, Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus.

[30]  J. McLaren,et al.  Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods. , 2004, American journal of ophthalmology.

[31]  Shan C. Lin,et al.  Central corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinic. , 2004, Ophthalmology.

[32]  Chris A. Johnson,et al.  The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. , 2002, Archives of ophthalmology.

[33]  K. Hoffer,et al.  Clinical results using the Holladay 2 intraocular lens power formula. , 2000, Journal of cataract and refractive surgery.

[34]  F. Price,et al.  Central corneal pachymetry in patients undergoing laser in situ keratomileusis. , 1999, Ophthalmology.

[35]  T. Avitabile,et al.  Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes. , 1997, Cornea.

[36]  T. H. Pettit,et al.  Reliability coefficients of three corneal pachymeters. , 1992, American journal of ophthalmology.

[37]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[38]  Laurent Degos,et al.  HISTOCOMPATIBILITY DETERMINANTS IN MULTIPLE SCLEROSIS , 1974 .