The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis.

In the present work a double ion sensor based on a laser scanned semiconductor transducer (LSST) for the simultaneous determination of K(+)- and Ca(2+)-ions in solutions has been developed. Specially elaborated ion-sensitive membrane compositions based on valinomycin and calcium ionophore calcium bis[4-(1,1,3,3-tetramethylbutyl)phenyl] phosphate (t-HDOPP-Ca) were deposited as separate layers on a silanized surface of the Si/SiO(2)/Si(3)N(4)-transducer. The proposed multi-sensor exhibits theoretical sensitivities and the detection limits of the sensor were found to be 2 x 10(-6) mol l(-1) for K(+) and 5 x 10(-6) mol l(-1) for Ca(2+). The elaborated double sensor is proposed for the first time as a prototype of a new type of multi-sensor systems for chemical analysis.

[1]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[2]  Zheng Xiaoxiang,et al.  Drug evaluations using a novel microphysiometer based on cell-based biosensors , 2001 .

[3]  Hiroshi Iwasaki,et al.  Photocurable membranes for ion-selective light-addressable potentiometric sensor , 2002 .

[4]  P. Debye,et al.  Dieletric Properties of Pure Liquids. , 1936 .

[5]  Teruaki Katsube,et al.  Integrated taste sensor using surface photovoltage technique , 1994 .

[6]  J. W. Parce,et al.  The light-addressable potentiometric sensor: principles and biological applications. , 1994, Annual review of biophysics and biomolecular structure.

[7]  Teruaki Katsube Light Adressable Potentiometric Chemical Sensing System , 1999 .

[8]  P Bergveld,et al.  Development of an ion-sensitive solid-state device for neurophysiological measurements. , 1970, IEEE transactions on bio-medical engineering.

[9]  J. W. Parce,et al.  Light-addressable potentiometric sensor for biochemical systems. , 1988, Science.

[10]  M. Madou,et al.  Chemical Sensing With Solid State Devices , 1989 .

[11]  I. Karube,et al.  Pulse immunoassay for Candida albicans. , 1985, Analytical chemistry.

[12]  李幼升,et al.  Ph , 1989 .

[13]  A R Midgley,et al.  Electrochemical performance, biocompatibility, and adhesion of new polymer matrices for solid-state ion sensors. , 1991, Analytical chemistry.

[14]  K. Seiler,et al.  Determination of complex formation constants of neutral cation-selective ionophores in solvent polymeric membranes , 1994 .

[15]  Izumi Kubo,et al.  Novel sensors for potassium, calcium and magnesium ions based on a silicon transducer as a light-addressable potentiometric sensor , 1999 .

[16]  Joseph Wang,et al.  Electrochemical detection for microscale analytical systems: a review. , 2002, Talanta.

[17]  Y. Vlasov,et al.  Non-selective chemical sensors in analytical chemistry: from “electronic nose” to “electronic tongue” , 1998 .

[18]  Jiří Koryta ION-Selective Electrodes , 1986 .

[19]  P. Bühlmann,et al.  EMF response of neutral-carrier based ion-sensitive field effect transistors with membranes free of ionic sites , 1995 .

[20]  Hiroshi Iwasaki,et al.  Scanning laser beam semiconductor pH imaging sensor , 1994 .

[21]  Willi Zander,et al.  Can pulsed laser deposition serve as an advanced technique in fabricating chemical sensors , 2001 .

[22]  Ari Ivaska,et al.  Calcium-selective electrode based on polyaniline functionalized with bis(4-(1,1,3,3-tetramethylbutyl)phenyl)phosphate , 2001 .

[23]  R L Solsky,et al.  Ion-selective electrodes. , 1982, Analytical chemistry.

[24]  H. Lüth,et al.  Development of multisensor systems based on chalcogenide thin film chemical sensors for the simultaneous multicomponent analysis of metal ions in complex solutions , 2001 .