Energy performance of supermarket refrigeration and air conditioning integrated systems working with natural refrigerants

Abstract The current trends in commercial refrigeration aim at reducing the synthetic refrigerant charge, either by minimising the internal volume of the circuit or by utilising natural refrigerants, and at energy saving. The energy efficiency of supermarkets can be improved by optimising components design, recovering thermal and refrigerating energy, adopting innovative technology solutions, integrating the HVAC system with medium temperature and low temperature refrigeration plants and, finally, reducing thermal loads on refrigerated cases. This study aims at investigating the performance of different lay-out and technological solutions where only natural refrigerants are used and at finding the potential for improving energy efficiency over the traditional systems in different climates. In the analysis, chillers and heat pumps working with ammonia or propane, medium temperature systems working with ammonia or propane and carbon dioxide as heat transfer fluid or with carbon dioxide as the refrigerant and low temperature systems working with carbon dioxide are considered and benchmarked with a state-of-the-art HFCs based plant. The most efficient investigated solution enables an annual energy saving higher than 15% with respect to the baseline solution for all the considered climates.

[1]  G. Lorentzen Revival of carbon dioxide as a refrigerant , 1994 .

[2]  F. Primal,et al.  Refrigeration systems with minimized refrigerant charge: System design and performance , 2005 .

[3]  Jörgen Rogstam,et al.  Experimental and Theoretical Evaluation of NH3/CO2 Cascade System for Supermarket Refrigeration in Laboratory Environment , 2006 .

[4]  C. L. Kusik,et al.  Energy and global warming impacts of CFC alternative technologies. Executive summary , 1991 .

[5]  Samer Sawalha,et al.  Theoretical evaluation of trans-critical CO2 systems in supermarket refrigeration. Part II: System modifications and comparisons of different solutions , 2008 .

[6]  M. Orphelin,et al.  Are there optimum temperature and humidity set points for supermarkets , 1999 .

[7]  Marco Corradi,et al.  Energy performance of supermarket refrigeration and air conditioning integrated systems , 2010 .

[8]  Jörgen Rogstam,et al.  Laboratory Tests of NH3/CO2 Cascade System for Supermarket Refrigeration , 2005 .

[9]  Liang Yang,et al.  Analysis on energy saving potential of integrated supermarket HVAC and refrigeration systems using multiple subcoolers , 2010 .

[10]  Andy Pearson,et al.  Refrigeration with ammonia , 2008 .

[11]  José Fernández-Seara,et al.  Theoretical analysis of a CO2–NH3 cascade refrigeration system for cooling applications at low temperatures , 2009 .

[12]  Marco Corradi,et al.  A simplified method to evaluate the seasonal energy performance of water chillers , 2010 .

[13]  J. Stene DESIGN AND APPLICATION OF AMMONIA HEAT PUMP SYSTEMS FOR HEATING AND COOLING OF NON-RESIDENTIAL BUILDINGS , 2008 .

[14]  B. Palm Hydrocarbons as refrigerants in small heat pump and refrigeration systems – A review , 2008 .

[15]  Mo Se Kim,et al.  Performance and heat transfer characteristics of hydrocarbon refrigerants in a heat pump system , 2000 .

[16]  Petter Nekså,et al.  Commercial refrigeration system using CO2 as the refrigerant , 2004 .

[17]  S. Svendsen,et al.  Residential and commercial buildings , 2012 .

[18]  Samer Sawalha,et al.  Theoretical evaluation of trans-critical CO2 systems in supermarket refrigeration. Part I: Modeling, simulation and optimization of two system solutions , 2008 .

[19]  C. James,et al.  The food cold-chain and climate change , 2010 .

[20]  Petter Nekså,et al.  Commercial refrigeration using CO2 as refrigerant : System design and experimental results. Discussion , 1998 .

[21]  Per Lundqvist,et al.  Modelling and experimental validation of advanced refrigeration systems in supermarkets , 2005 .

[22]  Davide Del Col,et al.  Performance of a large capacity propane heat pump with low charge heat exchangers , 2010 .

[23]  Liang Yang,et al.  On subcooler design for integrated two-temperature supermarket refrigeration system , 2011 .

[24]  Per Lundqvist,et al.  Heat recovery and floating condensing in supermarkets , 2006 .

[25]  Luis Pérez-Lombard,et al.  A review of HVAC systems requirements in building energy regulations , 2011 .

[26]  Savvas A. Tassou,et al.  Thermodynamic analysis of transcritical CO2 booster refrigeration systems in supermarket , 2011 .

[27]  M. Corradi,et al.  A simplified method to evaluate the energy performance of CO2 heat pump units , 2011 .

[28]  James M. Calm,et al.  The next generation of refrigerants – Historical review, considerations, and outlook , 2008 .

[29]  B. Palm Refrigeration systems with minimum charge of refrigerant. , 2007 .