Sparse parallel transmission on randomly perturbed spiral k-space trajectory.

Combination of parallel transmission and sparse pulse is able to shorten the excitation by using both the coil sensitivity and sparse k-space, showing improved fast excitation capability over the use of parallel transmission alone. However, to design an optimal k-space trajectory for sparse parallel transmission is a challenging task. In this work, a randomly perturbed sparse k-space trajectory is designed by modifying the path of a spiral trajectory along the sparse k-space data, and the sparse parallel transmission RF pulses are subsequently designed based on this optimal trajectory. This method combines the parallel transmission and sparse spiral k-space trajectory, potentially to further reduce the RF transmission time. Bloch simulation of 90° excitation by using a four channel coil array is performed to demonstrate its feasibility. Excitation performance of the sparse parallel transmission technique at different reduction factors of 1, 2, and 4 is evaluated. For comparison, parallel excitation using regular spiral trajectory is performed. The passband errors of the excitation profiles of each transmission are calculated for quantitative assessment of the proposed excitation method.

[1]  Xiaoliang Zhang,et al.  7T Transmit/Receive Arrays Using ICE Decoupling for Human Head MR Imaging , 2014, IEEE Transactions on Medical Imaging.

[2]  Daniel K Sodickson,et al.  Design and Application of Combined 8-Channel Transmit and 10-Channel Receive Arrays and Radiofrequency Shimming for 7-T Shoulder Magnetic Resonance Imaging , 2014, Investigative radiology.

[3]  Markus Vester,et al.  On‐coil multiple channel transmit system based on class‐D amplification and pre‐amplification with current amplitude feedback , 2013, Magnetic resonance in medicine.

[4]  Yong Pang,et al.  Interpolated Compressed Sensing for 2D Multiple Slice Fast MR Imaging , 2013, PloS one.

[5]  Sharmila Majumdar,et al.  Flexible transceiver array for ultrahigh field human MR imaging , 2012, Magnetic resonance in medicine.

[6]  Mark Griswold,et al.  Fast cardiac T1 mapping in mice using a model‐based compressed sensing method , 2012, Magnetic resonance in medicine.

[7]  Feng Liu,et al.  Compressed sensing MRI using Singular Value Decomposition based sparsity basis , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  Xiaoliang Zhang,et al.  Precompensation for mutual coupling between array elements in parallel excitation. , 2011, Quantitative imaging in medicine and surgery.

[9]  Stuart Crozier,et al.  Compressed sensing MRI with singular value decomposition-based sparsity basis , 2011, Physics in medicine and biology.

[10]  D. Vigneron,et al.  ICE decoupling technique for RF coil array designs. , 2011, Medical physics.

[11]  N. McDannold,et al.  Combining two‐dimensional spatially selective RF excitation, parallel imaging, and UNFOLD for accelerated MR thermometry imaging , 2011, Magnetic resonance in medicine.

[12]  Yogesh Rathi,et al.  Spatially Regularized Compressed Sensing for High Angular Resolution Diffusion Imaging , 2011, IEEE Transactions on Medical Imaging.

[13]  Tolga Çukur,et al.  Signal Compensation and Compressed Sensing for Magnetization-Prepared MR Angiography , 2011, IEEE Transactions on Medical Imaging.

[14]  Weiran Deng,et al.  Accelerated multidimensional radiofrequency pulse design for parallel transmission using concurrent computation on multiple graphics processing units , 2011, Magnetic resonance in medicine.

[15]  M. Lustig,et al.  Compressed sensing for chemical shift‐based water–fat separation , 2010, Magnetic resonance in medicine.

[16]  L. Ying,et al.  Compressed-sensing dynamic MR imaging with partially known support , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[17]  Ching-Hua Chang,et al.  Improved compressed sensing MRI with multi-channel data using reweighted l1 minimization , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[18]  Bing Wu,et al.  7T Human Spine Imaging Arrays With Adjustable Inductive Decoupling , 2010, IEEE Transactions on Biomedical Engineering.

[19]  Glen R. Morrell,et al.  An Analytic Framework for the Evaluation of Coil Configurations for Parallel Transmission MRI With Subsampled Cartesian Excitation k-Space , 2010, IEEE Transactions on Medical Imaging.

[20]  L. Ying,et al.  Accelerating SENSE using compressed sensing , 2009, Magnetic resonance in medicine.

[21]  M. Ladd,et al.  An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 T , 2009, Investigative radiology.

[22]  Shrikanth S. Narayanan,et al.  Accelerated three‐dimensional upper airway MRI using compressed sensing , 2009, Magnetic resonance in medicine.

[23]  J. Ji,et al.  Minimal-SAR RF pulse optimization for parallel transmission in MRI , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  Chen Zhao,et al.  Compressed sensing parallel Magnetic Resonance Imaging , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Vivek K Goyal,et al.  Specific absorption rate studies of the parallel transmission of inner‐volume excitations at 7T , 2008, Journal of magnetic resonance imaging : JMRI.

[26]  Seung-Jean Kim,et al.  A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories , 2008, IEEE Transactions on Medical Imaging.

[27]  G. Metzger,et al.  Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurements , 2008, Magnetic resonance in medicine.

[28]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[29]  Douglas C Noll,et al.  Joint design of trajectory and RF pulses for parallel excitation , 2007, Magnetic resonance in medicine.

[30]  Zhi-Pei Liang,et al.  A noniterative method to design large‐tip‐angle multidimensional spatially‐selective radio frequency pulses for parallel transmission , 2007, Magnetic resonance in medicine.

[31]  Douglas C Noll,et al.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice‐select pulses , 2007, Magnetic resonance in medicine.

[32]  Kawin Setsompop,et al.  Parallel RF transmission with eight channels at 3 Tesla , 2006, Magnetic resonance in medicine.

[33]  Douglas C Noll,et al.  Spatial domain method for the design of RF pulses in multicoil parallel excitation , 2006, Magnetic resonance in medicine.

[34]  Peter Börnert,et al.  Parallel RF transmission in MRI , 2006, NMR in biomedicine.

[35]  C. Hardy,et al.  32‐element receiver‐coil array for cardiac imaging , 2006, Magnetic resonance in medicine.

[36]  Walid E Kyriakos,et al.  Generalized encoding through the use of selective excitation in accelerated parallel MRI , 2006, NMR in biomedicine.

[37]  K. Uğurbil,et al.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging , 2005, Magnetic resonance in medicine.

[38]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[39]  K. Uğurbil,et al.  A microstrip transmission line volume coil for human head MR imaging at 4T. , 2003, Journal of magnetic resonance.

[40]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[41]  K. Uğurbil,et al.  Microstrip RF surface coil design for extremely high‐field MRI and spectroscopy , 2001, Magnetic resonance in medicine.

[42]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[43]  Gregory Chang,et al.  Compressed sensing sodium MRI of cartilage at 7T: preliminary study. , 2012, Journal of magnetic resonance.

[44]  Johnpauly A k-Space Analysis of Small-Tip-Angle Excitation , 2012 .

[45]  Gitta Kutyniok Compressed Sensing , 2012 .

[46]  Leon Axel,et al.  Combination of Compressed Sensing and Parallel Imaging for Highly-Accelerated 3 D First-Pass Cardiac Perfusion MRI , 2009 .

[47]  Y. Pang,et al.  Sparse parallel transmission using optimized sparse k-space trajectory by simulated annealing , 2009 .

[48]  M. W. Vogel,et al.  Sparse Parallel Transmit Pulse Design Using Orthogonal Matching Pursuit Method , 2008 .