A novel miniature robotic device for frameless implantation of depth electrodes in refractory epilepsy.

OBJECTIVE The authors' group recently published a novel technique for a navigation-guided frameless stereotactic approach for the placement of depth electrodes in epilepsy patients. To improve the accuracy of the trajectory and enhance the procedural workflow, the authors implemented the iSys1 miniature robotic device in the present study into this routine. METHODS As a first step, a preclinical phantom study was performed using a human skull model, and the accuracy and timing between 5 electrodes implanted with the manual technique and 5 with the aid of the robot were compared. After this phantom study showed an increased accuracy with robot-assisted electrode placement and confirmed the robot's ability to maintain stability despite the rotational forces and the leverage effect from drilling and screwing, patients were enrolled and analyzed for robot-assisted depth electrode placement at the authors' institution from January 2014 to December 2015. All procedures were performed with the S7 Surgical Navigation System with Synergy Cranial software and the iSys1 miniature robotic device. RESULTS Ninety-three electrodes were implanted in 16 patients (median age 33 years, range 3-55 years; 9 females, 7 males). The authors saw a significant increase in accuracy compared with their manual technique, with a median deviation from the planned entry and target points of 1.3 mm (range 0.1-3.4 mm) and 1.5 mm (range 0.3-6.7 mm), respectively. For the last 5 patients (31 electrodes) of this series the authors modified their technique in placing a guide for implantation of depth electrodes (GIDE) on the bone and saw a significant further increase in the accuracy at the entry point to 1.18 ± 0.5 mm (mean ± SD) compared with 1.54 ± 0.8 mm for the first 11 patients (p = 0.021). The median length of the trajectories was 45.4 mm (range 19-102.6 mm). The mean duration of depth electrode placement from the start of trajectory alignment to fixation of the electrode was 15.7 minutes (range 8.5-26.6 minutes), which was significantly faster than with the manual technique. In 12 patients, depth electrode placement was combined with subdural electrode placement. The procedure was well tolerated in all patients. The authors did not encounter any case of hemorrhage or neurological deficit related to the electrode placement. In 1 patient with a psoriasis vulgaris, a superficial wound infection was encountered. Adequate physiological recordings were obtained from all electrodes. No additional electrodes had to be implanted because of misplacement. CONCLUSIONS The iSys1 robotic device is a versatile and easy to use tool for frameless implantation of depth electrodes for the treatment of epilepsy. It increased the accuracy of the authors' manual technique by 60% at the entry point and over 30% at the target. It further enhanced and expedited the authors' procedural workflow.

[1]  Sebastien Ourselin,et al.  A Novel Method for Implementation of Frameless StereoEEG in Epilepsy Surgery , 2014, Neurosurgery.

[2]  R. Maciunas,et al.  The application accuracy of stereotactic frames. , 1994, Neurosurgery.

[3]  M. Cook,et al.  Insertion of depth electrodes with or without subdural grids using frameless stereotactic guidance systems -- technique and outcome , 2002, British journal of neurosurgery.

[4]  Gabriele Arnulfo,et al.  Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. , 2013, Neurosurgery.

[5]  Abhilash Pandya,et al.  The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[6]  Denys Fontaine,et al.  In vivo measurement of the frame-based application accuracy of the Neuromate neurosurgical robot. , 2015, Journal of neurosurgery.

[7]  J. Henderson,et al.  Frameless stereotaxy using bone fiducial markers for deep brain stimulation. , 2005, Journal of neurosurgery.

[8]  Theodore H Schwartz,et al.  Frameless stereotactic placement of depth electrodes in epilepsy surgery. , 2005, Journal of neurosurgery.

[9]  Juan Bulacio,et al.  The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients. , 2014, Journal of neurosurgery.

[10]  Juan Bulacio,et al.  Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography. , 2016, Neurosurgery.

[11]  E. Pataraia,et al.  Frameless Stereotactic Drilling for Placement of Depth Electrodes in Refractory Epilepsy: Operative Technique and Initial Experience , 2014, Neurosurgery.

[12]  R Steinmeier,et al.  Factors Influencing the Application Accuracy of Neuronavigation Systems , 2002, Stereotactic and Functional Neurosurgery.

[13]  I. Kassim,et al.  Image-guided robotic neurosurgery--an in vitro and in vivo point accuracy evaluation experimental study. , 2009, Surgical neurology.

[14]  J. Talairach,et al.  Stereotaxic Approach to Epilepsy , 1973 .

[15]  Jorge Gonzalez-Martinez,et al.  Stereotactic placement of depth electrodes in medically intractable epilepsy. , 2014, Journal of neurosurgery.

[16]  H. Bjartmarz,et al.  Comparison of Accuracy and Precision between Frame-Based and Frameless Stereotactic Navigation for Deep Brain Stimulation Electrode Implantation , 2007, Stereotactic and Functional Neurosurgery.