Electrolyte-free Amperometric Immunosensor using a Dendritic Nanotip.

Electric detection using a nanocomponent may lead to platforms for rapid and simple biosensing. Sensors composed of nanotips or nanodots have been described for highly sensitive amperometry enabled by confined geometry. However, both fabrication and use of nanostructured sensors remain challenging. This paper describes a dendritic nanotip used as an amperometric biosensor for highly sensitive detection of target bacteria. A dendritic nanotip is structured by Si nanowires coated with single-walled carbon nanotubes (SWCNTs) for generation of a high electric field. For reliable measurement using the dendritic structure, Si nanowires were uniformly fabricated by ultraviolet (UV) lithography and etching. The dendritic structure effectively increased the electric current density near the terminal end of the nanotip according to numerical computation. The electrical characteristics of a dendritic nanotip with additional protein layers was studied by cyclic voltammetry and I-V measurement in deionized (DI) water. When the target bacteria dielectrophoretically captured onto a nanotip were bound with fluorescence antibodies, the electric current through DI water decreased. Measurement results were consistent with fluorescence- and electron microscopy. The sensitivity of the amperometry was 10 cfu/sample volume (103 cfu/mL), which was equivalent to the more laborious fluorescence measurement method. The simple configuration of a dendritic nanotip can potentially offer an electrolyte-free detection platform for sensitive and rapid biosensors.

[1]  Anubhav Tripathi,et al.  Nanoneedle method for high-sensitivity low-background monitoring of protein activity. , 2008, Langmuir : the ACS journal of surfaces and colloids.

[2]  Woon-Hong Yeo,et al.  Hybrid nanofibril assembly using an alternating current electric field and capillary action. , 2009, Journal of nanoscience and nanotechnology.

[3]  Kong,et al.  Nanotube molecular wires as chemical sensors , 2000, Science.

[4]  Long Jiang,et al.  Nanogold hollow balls with dendritic surface for hybridization of DNA. , 2007, Biosensors & bioelectronics.

[5]  J. Kop,et al.  Evaluation of the Analytical Performance of the Xpert MTB/RIF Assay , 2010, Journal of Clinical Microbiology.

[6]  A. Star,et al.  Carbon Nanotube Field‐Effect‐Transistor‐Based Biosensors , 2007 .

[7]  D Griffiths,et al.  Biosensors--what real progress is being made? , 1993, Trends in biotechnology.

[8]  Yuehe Lin,et al.  Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles , 2004 .

[9]  Woon-Hong Yeo,et al.  Nanoscale sensor analysis using the immersed molecular electrokinetic finite element method. , 2012, Nanoscale.

[10]  K. Balasubramanian,et al.  Functionalized metallic carbon nanotube devices for pH sensing. , 2007, Chemphyschem : a European journal of chemical physics and physical chemistry.

[11]  S. Jun,et al.  A microwire sensor for rapid detection of Escherichia coli K-12 in fresh produce , 2011 .

[12]  George Grüner Carbon nanotube transistors for biosensing applications. , 2005 .

[13]  Woon-Hong Yeo,et al.  Size-selective immunofluorescence of Mycobacterium tuberculosis cells by capillary- and viscous forces. , 2010, Lab on a chip.

[14]  Eduardo Gotuzzo,et al.  Rapid molecular detection of tuberculosis and rifampin resistance. , 2010, The New England journal of medicine.

[15]  Cees Dekker,et al.  Individual single-walled carbon nanotubes as nanoelectrodes for electrochemistry. , 2005, Nano letters.

[16]  Donhee Ham,et al.  Chip–NMR biosensor for detection and molecular analysis of cells , 2008, Nature Medicine.

[17]  Ning Wang,et al.  Nanoneedle: a multifunctional tool for biological studies in living cells. , 2010, Nanoscale.

[18]  Young Hee Lee,et al.  Electrochemical nanoneedle biosensor based on multiwall carbon nanotube. , 2006, Analytical chemistry.

[19]  Cees Dekker,et al.  Fabrication and characterization of nanopore-based electrodes with radii down to 2 nm. , 2006, Nano letters.

[20]  Feng Li,et al.  Development of an electrochemical DNA biosensor with a high sensitivity of fM by dendritic gold nanostructure modified electrode. , 2011, Biosensors & bioelectronics.

[21]  Woon-Hong Yeo,et al.  Immunosensor towards low-cost, rapid diagnosis of tuberculosis. , 2012, Lab on a chip.

[22]  J. Kong,et al.  Electrochemistry at single-walled carbon nanotubes: the role of band structure and quantum capacitance. , 2006, Journal of the American Chemical Society.

[23]  Kristen L. Helton,et al.  Microfluidic Overview of Global Health Issues Microfluidic Diagnostic Technologies for Global Public Health , 2006 .

[24]  Zbigniew Stojek,et al.  Peer Reviewed: Voltammetric and Amperometric Detection without Added Electrolyte. , 2000 .

[25]  Woon-Hong Yeo,et al.  Dielectrophoretic concentration of low-abundance nanoparticles using a nanostructured tip , 2012, Nanotechnology.

[26]  Woon-Hong Yeo,et al.  Rapid detection of Mycobacterium tuberculosis cells by using microtip-based immunoassay , 2009, Analytical and bioanalytical chemistry.

[27]  Ruth McNerney,et al.  Towards a point-of-care test for active tuberculosis: obstacles and opportunities , 2011, Nature Reviews Microbiology.

[28]  Woon-Hong Yeo,et al.  Size-specific concentration of DNA to a nanostructured tip using dielectrophoresis and capillary action. , 2009, The journal of physical chemistry. B.

[29]  Bernhard Weigl,et al.  Towards non- and minimally instrumented, microfluidics-based diagnostic devices. , 2008, Lab on a chip.

[30]  Y. K. Cheung,et al.  1 Supplementary Information for : Microfluidics-based diagnostics of infectious diseases in the developing world , 2011 .