Three-dimensional electrogoniometric gait recording.

Gait recordings of twenty healthy subjects were made on a treadmill and on level ground by means of a light-weight computerised electrogoniometer. The angular excursions in three planes were recorded simultaneously with regard to hip, knee and ankle joints in both legs. Determinations of the mean values and dispersions were then made. In order to establish the reliability of the method tests and retests were performed. Also its validity was checked by comparing the goniometric recordings with concomitant measurements obtained by other methods. The reliability and validity of the method was found to be satisfactory. Apart from flexion of the hip and knee joints during stance phase (i.e. a difference of 2 and 2.4 degrees respectively), no difference was ascertained between walking on a treadmill and walking on level ground.

[1]  Karpovich Pv,et al.  Electrogoniometric study of joints. , 1960 .

[2]  G. Smidt,et al.  Measurement of hip-joint motion during walking. Evaluation of an electrogoniometric method. , 1969, The Journal of bone and joint surgery. American volume.

[3]  E. Chao,et al.  Justification of triaxial goniometer for the measurement of joint rotation. , 1980, Journal of biomechanics.

[4]  A. B. Drought,et al.  WALKING PATTERNS OF NORMAL MEN. , 1964, The Journal of bone and joint surgery. American volume.

[5]  G. Smidt,et al.  Measurement of hip joint motion during walking , 1969 .

[6]  E. Y. Chao,et al.  Biomechanical gait evaluation of pre and postoperative total knee replacement patients , 2004, Archives of orthopaedic and traumatic surgery.

[7]  T. Andriacchi,et al.  The influence of total knee-replacement design on walking and stair-climbing. , 1982, The Journal of bone and joint surgery. American volume.

[8]  E. Chao,et al.  Changes in knee function associated with treadmill ambulation. , 1983, Journal of biomechanics.

[9]  Objective recording of human gait, a quantitative evaluation of two techniques. Electrogoniometry and interrupted light photography. , 1980, Acta orthopaedica Belgica.

[10]  A. S. Levens,et al.  Transverse rotation of the segments of the lower extremity in locomotion. , 1948, The Journal of bone and joint surgery. American volume.

[11]  E Y Chao,et al.  The application of 4 x 4 matrix method to the correction of the measurements of hip joint rotations. , 1970, Journal of biomechanics.

[12]  E. Chao,et al.  An electrogoniometric study of knee motion in normal gait. , 1970, The Journal of bone and joint surgery. American volume.

[13]  William Cohen,et al.  An automated motion measurement system for clinical gait analysis. , 1982 .

[14]  Lamoreux Lw Kinematic measurements in the study of human walking. , 1971 .