Photoacoustic imaging with a commercial ultrasound system and a custom probe.

Building photoacoustic imaging (PAI) systems by using stand-alone ultrasound (US) units makes it convenient to take advantage of the state-of-the-art ultrasonic technologies. However, the sometimes limited receiving sensitivity and the comparatively narrow bandwidth of commercial US probes may not be sufficient to acquire high quality photoacoustic images. In this work, a high-speed PAI system has been developed using a commercial US unit and a custom built 128-element piezoelectric-polymer array (PPA) probe using a P(VDF-TrFE) film and flexible circuit to define the elements. Since the US unit supports simultaneous signal acquisition from 64 parallel receive channels, PAI data for synthetic image formation from a 64- or 128-element array aperture can be acquired after a single or dual laser firing, respectively. Therefore, two-dimensional (2-D) B-scan imaging can be achieved with a maximum frame rate up to 10 Hz, limited only by the laser repetition rate. The uniquely properties of P(VDF-TrFE) facilitated a wide -6 dB receiving bandwidth of over 120% for the array. A specially designed 128-channel preamplifier board made the connection between the array and the system cable, which not only enabled element electrical impedance matching but also further elevated the signal-to-noise ratio (SNR) to further enhance the detection of weak photoacoustic signals. Through the experiments on phantoms and rabbit ears, the good performance of this PAI system was demonstrated.

[1]  Robert A Kruger,et al.  Thermoacoustic molecular imaging of small animals. , 2003, Molecular imaging.

[2]  Wiendelt Steenbergen,et al.  The Twente Photoacoustic Mammoscope: system overview and performance , 2005, Physics in medicine and biology.

[3]  Qifa Zhou,et al.  Design and fabrication of PIN-PMN-PT single-crystal high-frequency ultrasound transducers , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Liang Song,et al.  Ultrasound-array-based real-time photoacoustic microscopy of human pulsatile dynamics in vivo. , 2010, Journal of biomedical optics.

[5]  Minghua Xu,et al.  Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[6]  Jiyan Dai,et al.  Multiple matching scheme for broadband 0.72Pb(Mg1/3Nb2/3)O3−0.28PbTiO3 single crystal phased-array transducer , 2009 .

[7]  Lihong V. Wang,et al.  Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain , 2003, Nature Biotechnology.

[8]  Ivan Pelivanov,et al.  Focused array transducer for two-dimensional optoacoustic tomography. , 2004, The Journal of the Acoustical Society of America.

[9]  L. Brown Design considerations for piezoelectric polymer ultrasound transducers , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Quing Zhu,et al.  Real-time photoacoustic tomography of cortical hemodynamics in small animals. , 2010, Journal of biomedical optics.

[11]  X. Wang,et al.  Experimental evaluation of a high-speed photoacoustic tomography system based on a commercial ultrasound unit , 2008, 2008 IEEE Ultrasonics Symposium.

[12]  Aya Kamaya,et al.  Three-dimensional photoacoustic imaging using a two-dimensional CMUT array , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  M. A. Yaseen,et al.  Optoacoustic imaging of the prostate: development toward image-guided biopsy. , 2010, Journal of biomedical optics.

[14]  Xinmai Yang,et al.  Photoacoustic tomography of small animal brain with a curved array transducer. , 2009, Journal of biomedical optics.

[15]  Alexander A. Oraevsky,et al.  Optoacoustic tomography: New modality of laser diagnostic systems , 2003 .

[16]  B. Khuri-Yakub,et al.  Surface micromachined capacitive ultrasonic transducers , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Manojit Pramanik,et al.  Sentinel lymph nodes in the rat: noninvasive photoacoustic and US imaging with a clinical US system. , 2010, Radiology.

[18]  Ketan Mehta,et al.  128-channel laser optoacoustic imaging system (LOIS-128) for breast cancer diagnostics , 2006, SPIE BiOS.

[19]  A. Oraevsky,et al.  Laser optoacoustic imaging system for detection of breast cancer. , 2009, Journal of biomedical optics.

[20]  Huabei Jiang,et al.  Quantitative two-dimensional photoacoustic tomography of osteoarthritis in the finger joints. , 2010, Optics express.

[21]  Reindert Graaff,et al.  Flat ended steel wires, backscattering targets for calibrating over a large dynamic range. , 2006, Ultrasound in medicine & biology.

[22]  Xueding Wang,et al.  Noninvasive photoacoustic tomography of human peripheral joints toward diagnosis of inflammatory arthritis. , 2007, Optics letters.

[23]  S. Carey,et al.  Scanning Head with 128-Element 20-MHz PVDF Linear Array Transducer , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Wiendelt Steenbergen,et al.  Real-time in vivo photoacoustic and ultrasound imaging. , 2008, Journal of biomedical optics.

[25]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.