Improvement on the corona model of ultra high voltage alternating current transmission lines

In designing lightning insulation margin of substation equipment in China, the attenuation and distortion of intruding wave caused by corona in the transmission lines is neglected, thus making too strict insulation requirements on the electrical equipment, what's more, the impulse corona has a great impact on the shielding failure and lightning resisting level of ultra high voltage alternating current (UHV AC) transmission line, making it necessary to study the corona effect of UHV AC transmission lines. In this paper, a corona model is put forward in which the coupling among the wires and corona in the overhead ground wire are taken into consideration and the capacity changes of wire to ground is taken into consideration as well after conducting the parallel connection between corona capacity and air capacity in the ionization zone then carrying out the series connection with the air capacity in none-ionization zone so as to simulate the corona. Such model is more favorable to the actual conditions of corona discharging. The lightning shielding failure ATP-EMTP corona model in the UHV AC transmission line, to which the corona mentioned above, is added will be established. The results show that corona has the impact on the wave passing through the transmission line, causing the attenuation and distortion of amplitude and slope of lighting wave, thus improving the shielding failure and lightning resistance level of the transmission line.

[1]  Chen Shuiming Experimental Researches on Lightning Impulse Corona Characteristics of Conductors , 2012 .

[2]  Abner Ramirez,et al.  Electromagnetic transients in overhead lines considering frequency dependence and corona effect via the method of characteristics , 2001 .

[3]  Jose R. Marti,et al.  Wide-band corona circuit model for transient simulations , 1995 .

[4]  M. Rioual,et al.  Damping model of travelling waves by corona effect along extra high voltage three phase lines , 1995 .

[5]  Du Zhongdong Study on the Lightning Protection of Shielding Failure for 1000kV UHV Transmission Lines , 2006 .

[6]  Wang Jian-min Design of Multi-Surge Impedance Model for Ultra-High Transmission Tower and Analysis onIts Transient Characteristic Caused by Lightning Stroke , 2007 .

[7]  Sun Wei Analysis of Lightning Shielding Failure Proof Level of UHV Transmission Lines Considering Corona Influences , 2009 .

[8]  C. F. Wagner,et al.  Effects of Corona on Traveling Waves [includes discussion] , 1955, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[9]  Dai Yu An Equivalent Circuit Model of the Multiphase Transmission Lines Affected by the Corona , 2000 .

[10]  Xie Bo Identification Method of Back Flash Overvoltage and Shielding Failure of Transmission Lines Considering the Effect of Impulse Corona , 2011 .

[11]  傅闯,et al.  Overvoltage Protection and Insulation Coordination for DC De-icer with Static Var Compensator , 2013 .

[12]  S. Carneiro,et al.  Evaluation of Corona and Line Models in Electromagnetic Transients Simulations , 1991, IEEE Power Engineering Review.

[14]  Mohammad Khalifa High-voltage engineering : theory and practice , 1990 .