Performance evaluation of online transformer internal fault detection based on transient overvoltage signals

Winding deformation is a critical power transformer issue that needs to be detected as soon as it emerges due to its progressive nature and severe consequences it may lead to. Frequency response analysis (FRA) is the only reliable technique currently used to detect such deformation. However, the technique is conducted offline that may cause interruption to the electricity grid when taking an operating transformer out of service for testing. Moreover, as the current FRA technique is only conducted on suspected units, a mechanical fault may emerge and progress before the utility becomes aware of. To overcome these limitations, this paper presents a practical feasibility study to detect transformer winding deformations online. The technique relies on utilizing transient overvoltage signals that a transformer is subjected to during its normal operation as a natural variable frequency excitation source. The feasibility of utilizing various transient overvoltage signals as excitation source for transformer FRA signature measurement is firstly investigated and optimum signal parameters are recommended based on signal voltage and energy spectrum analyses. Secondly, the proposed technique is verified through simulation analysis by comparing the transformer frequency response signatures when transient overvoltage and conventional sweep frequency voltage are used as excitation sources. Also, experimental testing is conducted to assess the feasibility of the proposed technique to identify various winding deformations such as radial buckling, telescoping and short circuit turns. Custom-made capacitive voltage divider is developed to accurately detect the response of transient overvoltage signals generated due to environmental conditions or power system switching operations. The proposed technique along with the developed capacitive voltage divider is implemented on a 3-phase Wye-Delta, 50 Hz, 31.5 MVA, 110/10.5 kV power transformer to measure the frequency response signatures of the high voltage winding.

[1]  Mehdi Bagheri,et al.  Transformer frequency response analysis: mathematical and practical approach to interpret mid-frequency oscillations , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[2]  Mi Ya Development of Circulative Reactor Used for Purification of Contaminated Transformer Oil with DC-steep Pulse Electric Field , 2014 .

[3]  Bo Tan,et al.  Computer Modeling and Simulation of Impulsive Grounding , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[4]  A. Abu-Siada,et al.  Online Transformer Internal Fault Detection Based on Instantaneous Voltage and Current Measurements Considering Impact of Harmonics , 2017, IEEE Transactions on Power Delivery.

[5]  A. Abu-Siada,et al.  Improved power transformer winding fault detection using FRA diagnostics – part 1: axial displacement simulation , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  François Gagnon,et al.  Impacts of impulsive noise from partial discharges on wireless systems performance: application to MIMO precoders , 2011, EURASIP J. Wirel. Commun. Netw..

[7]  Gevork B. Gharehpetian,et al.  Determination of Transformer Winding Radial Deformation Using UWB System and Hyperboloid Method , 2015, IEEE Sensors Journal.

[8]  A. Abu-Siada,et al.  A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.

[9]  Ming Jin,et al.  Effects of insulation paper ageing on the vibration characteristics of a transformer winding disk , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Mehdi Bagheri,et al.  Frequency response analysis and short-circuit impedance measurement in detection of winding deformation within power transformers , 2013, IEEE Electrical Insulation Magazine.

[11]  A. Abu-Siada,et al.  Application of digital image processing to detect transformer bushing faults and oil degradation using FRA polar plot signature , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  S. Borucki,et al.  Diagnosis of Technical Condition of Power Transformers Based on the Analysis of Vibroacoustic Signals Measured in Transient Operating Conditions , 2012, IEEE Transactions on Power Delivery.

[13]  Kaixing Hong,et al.  Winding Condition Assessment of Power Transformers Based on Vibration Correlation , 2015, IEEE Transactions on Power Delivery.

[14]  Chenguo Yao,et al.  Noninvasive method for online detection of internal winding faults of 750 kV EHV shunt reactors , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  Li Chengxiang Selection of Waveform for DC-steep Pulse Field in Transformer Oil Purifying , 2012 .

[16]  Ahmed Abu-Siada,et al.  Application of DIP to Detect Power Transformers Axial Displacement and Disk Space Variation Using FRA Polar Plot Signature , 2017, IEEE Transactions on Industrial Informatics.

[17]  A. Abu-Siada,et al.  Understanding power transformer frequency response analysis signatures , 2013, IEEE Electrical Insulation Magazine.

[18]  Chenguo Yao,et al.  Transformer winding deformation diagnostic system using online high frequency signal injection by capacitive coupling , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  A. Abu-Siada,et al.  Improved power transformer winding fault detection using FRA diagnostics – part 2: radial deformation simulation , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  Liu Dichen,et al.  Electromagnetic vibration noise analysis of transformer windings and core , 2016 .

[21]  T. Leibfried,et al.  Monitoring of power transformers using the transfer function method , 1999 .

[22]  Ahmed Abu-Siada,et al.  Application of Digital Image Processing to Detect Short-Circuit Turns in Power Transformers Using Frequency Response Analysis , 2016, IEEE Transactions on Industrial Informatics.

[23]  K. D. Srivastava,et al.  Review of condition assessment of power transformers in service , 2002 .

[24]  Transformer sweep frequency response analysis ( SFRA ) , .

[25]  Qing Yang,et al.  Statistical analysis on measured lightning overvoltage surges in a 110 kV air-insulated substation , 2015 .

[26]  A.J. Vandermaar,et al.  Improved detection of power transformer winding movement by extending the FRA high frequency range , 2005, IEEE Transactions on Power Delivery.

[27]  Xing Lan,et al.  Study on voltage-number characteristics of transformer insulation under transformer invading non-standard lightning impulses , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[28]  H. Borsi,et al.  A new diagnostic method to support standard frequency response analysis assessments for diagnostics of transformer winding mechanical failures , 2014, IEEE Electrical Insulation Magazine.

[29]  K. D. Srivastava,et al.  Condition monitoring of transformers in service by the low voltage impulse test method , 1999 .

[30]  Fan Yang,et al.  A study of the sweep frequency impedance method and its application in the detection of internal winding short circuit faults in power transformers , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[31]  Chenguo Yao,et al.  Improved Online Monitoring Method for Transformer Winding Deformations Based on the Lissajous Graphical Analysis of Voltage and Current , 2015, IEEE Transactions on Power Delivery.

[32]  Reza Iravani,et al.  Modelling and analysis guidelines for very fast transients , 1996 .